Section FGC 402: Pipe Sizing

402.1 General considerations. Piping systems shall be of such size and so installed as to provide a supply of gas sufficient to meet the maximum demand and supply gas to each appliance inlet at not less than the minimum supply pressure required by the appliance. 402.2 Maximum gas demand. The volumetric flow rate of gas to be provided shall be the sum of the maximum input of the appliances served. The total connected hourly load shall be used as the basis for pipe sizing, assuming that all appliances could be operating at full capacity simultaneously. Where a diversity of load can be established, pipe sizing shall be permitted to be based on such loads. The volumetric flow rate of gas to be provided shall be adjusted for altitude where the installation is above 2,000 feet (610 m) in elevation. 402.3 Sizing. Gas piping shall be sized in accordance with one of the following: 1. Pipe sizing tables or sizing equations in accordance with Section 402.4. 2. The sizing tables included in a listed piping system's manufacturer's instructions. 3. Other approved engineering methods. 4. Individual outlets to gas ranges shall not be less than 3/4 inches (19.1 mm) NPS. 402.4 Sizing tables and equations. Where Tables 402.4(1) through 402.4(7) are used to size piping or tubing, the pipe length shall be determined in accordance with Section 402.4.1, 402.4.2 or 402.4.3. Where Equations 4-1 and 4-2 are used to size piping or tubing, the pipe or tubing shall have smooth inside walls and the pipe length shall be determined in accordance with Section 402.4.1, 402.4.2 or 402.4.3. 1. Low-pressure gas equation (Less than 1 1/2 pounds per square inch (psi) (10.3 kPa)): ![Figure: FGCEq4-1](https://figures.74-208-44-221.nip.io/nyc/2026-10-user-export/admin/0-0-0-23002.jpg) (Equation 4-1) 2. High-pressure gas equation (1 1/2 psi (10.3 kPa) and above): ![Figure: FGCEq4-2](https://figures.74-208-44-221.nip.io/nyc/2026-10-user-export/admin/0-0-0-23004.jpg) (Equation 4-2) where: D = Inside diameter of pipe, inches (mm). Q = Input rate appliance(s), cubic feet per hour at 60°F (15.6 °C) and 30-inch mercury column. P1 = Upstream pressure, psia (P1 + 14.7). P2 = Downstream pressure, psia (P2 + 14.7). L = Equivalent length of pipe, feet. ΔH = Pressure drop, inch water column (27.7 inch water column = 1 psi). Table 402.4 Cr and Y Values for Natural Gas at Standard Conditions Gas Equation Factors Cr Y Natural gas 0.6094 0.9992 For SI: 1 cubic foot = 0.028 m3, 1 foot = 305 mm, 1-inch water column = 0.2488 kPa, 1 pound per square inch = 6.895 kPa, 1 British thermal unit per hour = 0.293 W. Table 402.4(1) Schedule 40 Metallic Pipe Gas Natural Inlet Pressure Less than 2 psi Pressure Drop .3 in. w.c. Specific Gravity 0.60 Pipe Size (inch) Nominal 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 5 6 8 10 12 Actual ID 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026 5.047 6.065 7.981 10.020 11.938 Length (ft) Capacity in Cubic Feet of Gas Per Hour 10 131 273 514 1,060 1,580 3,050 4,860 8,580 17,500 31,700 51,300 105,000 191,000 303,000 20 90 188 353 726 1,090 2,090 3,340 5,900 12,000 21,800 35,300 72,400 132,000 208,000 30 72 151 284 583 873 1,680 2,680 4,740 9,660 17,500 28,300 58,200 106,000 167,000 40 62 129 243 499 747 1,440 2,290 4,050 8,270 15,000 24,200 49,800 90,400 143,000 50 55 114 215 442 662 1,280 2,030 3,590 7,330 13,300 21,500 44,100 80,100 127,000 60 50 104 195 400 600 1,160 1,840 3,260 6,640 12,000 19,500 40,000 72,600 115,000 70 46 95 179 368 552 1,060 1,690 3,000 6,110 11,100 17,900 36,800 66,800 106,000 80 42 89 167 343 514 989 1,580 2,790 5,680 10,300 16,700 34,200 62,100 98,400 90 40 83 157 322 482 928 1,480 2,610 5,330 9,650 15,600 32,100 58,300 92,300 100 38 79 148 304 455 877 1,400 2,470 5,040 9,110 14,800 30,300 55,100 87,200 125 33 70 131 269 403 777 1,240 2,190 4,460 8,080 13,100 26,900 48,800 77,300 150 30 63 119 244 366 704 1,120 1,980 4,050 7,320 11,900 24,300 44,200 70,000 175 28 58 109 224 336 648 1,030 1,820 3,720 6,730 10,900 22,400 40,700 64,400 200 26 54 102 209 313 602 960 1,700 3,460 6,260 10,100 20,800 37,900 59,900 250 23 48 90 185 277 534 851 1,500 3,070 5,550 8,990 18,500 33,500 53,100 300 21 43 82 168 251 484 771 1,360 2,780 5,030 8,150 16,700 30,400 48,100 350 19 40 75 154 231 445 709 1,250 2,560 4,630 7,490 15,400 28,000 44,300 400 18 37 70 143 215 414 660 1,170 2,380 4,310 6,970 14,300 26,000 41,200 450 17 35 66 135 202 389 619 1,090 2,230 4,040 6,540 13,400 24,400 38,600 500 16 33 62 127 191 367 585 1,030 2,110 3,820 6,180 12,700 23,100 36,500 550 15 31 59 121 181 349 556 982 2,000 3,620 5,870 12,100 21,900 34,700 600 14 30 56 115 173 333 530 937 1,910 3,460 5,600 11,500 20,900 33,100 650 14 29 54 110 165 318 508 897 1,830 3,310 5,360 11,000 20,000 31,700 700 13 27 52 106 159 306 488 862 1,760 3,180 5,150 10,600 19,200 30,400 750 13 26 50 102 153 295 470 830 1,690 3,060 4,960 10,200 18,500 29,300 800 12 26 48 99 148 285 454 802 1,640 2,960 4,790 9,840 17,900 28,300 850 12 25 46 95 143 275 439 776 1,580 2,860 4,640 9,530 17,300 27,400 900 11 24 45 93 139 267 426 752 1,530 2,780 4,500 9,240 16,800 26,600 950 11 23 44 90 135 259 413 731 1,490 2,700 4,370 8,970 16,300 25,800 1,000 11 23 43 87 131 252 402 711 1,450 2,620 4,250 8,720 15,800 25,100 1,100 10 21 40 83 124 240 382 675 1,380 2,490 4,030 8,290 15,100 23,800 1,200 NA 20 39 79 119 229 364 644 1,310 2,380 3,850 7,910 14,400 22,700 1,300 NA 20 37 76 114 219 349 617 1,260 2,280 3,680 7,570 13,700 21,800 1,400 NA 19 35 73 109 210 335 592 1,210 2,190 3,540 7,270 13,200 20,900 1,500 NA 18 34 70 105 203 323 571 1,160 2,110 3,410 7,010 12,700 20,100 1,600 NA 18 33 68 102 196 312 551 1,120 2,030 3,290 6,770 12,300 19,500 1,700 NA 17 32 66 98 189 302 533 1,090 1,970 3,190 6,550 11,900 18,800 1,800 NA 16 31 64 95 184 293 517 1,050 1,910 3,090 6,350 11,500 18,300 1,900 NA 16 30 62 93 178 284 502 1,020 1,850 3,000 6,170 11,200 17,700 2,000 NA 16 29 60 90 173 276 488 1,000 1,800 2,920 6,000 10,900 17,200 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 kPa, 1-inch water column = 0.2488 kPa, 1 British thermal unit per hour = 0.293 1 W, 1 cubic foot per hour = 0.0283 m3/h, 1 degree = 0.0 1745 rad. Notes: 1. NA means a flow of less than 10 cfh. 2. All table entries have been rounded to three significant digits. Table 402.4(2) Schedule 40 Metallic Pipe Gas Natural Inlet Pressure Less than 2 psi Pressure Drop 0.5 in. w.c. Specific Gravity 0.60 Pipe Size (inch) Nominal 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 5 6 8 10 12 Actual ID 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026 5.047 6.065 7.981 10.020 11.938 Length (ft) Capacity in Cubic Feet of Gas Per Hour 10 172 360 678 1,390 2,090 4,020 6,400 11,300 23,100 41,800 67,600 139,000 252,000 399,000 20 118 247 466 957 1,430 2,760 4,400 7,780 15,900 28,700 46,500 95,500 173,000 275,000 30 95 199 374 768 1,150 2,220 3,530 6,250 12,700 23,000 37,300 76,700 139,000 220,000 40 81 170 320 657 985 1,900 3,020 5,350 10,900 19,700 31,900 65,600 119,000 189,000 50 72 151 284 583 873 1,680 2,680 4,740 9,660 17,500 28,300 58,200 106,000 167,000 60 65 137 257 528 791 1,520 2,430 4,290 8,760 15,800 25,600 52,700 95,700 152,000 70 60 126 237 486 728 1,400 2,230 3,950 8,050 14,600 23,600 48,500 88,100 139,000 80 56 117 220 452 677 1,300 2,080 3,670 7,490 13,600 22,000 45,100 81,900 130,000 90 52 110 207 424 635 1,220 1,950 3,450 7,030 12,700 20,600 42,300 76,900 122,000 100 50 104 195 400 600 1,160 1,840 3,260 6,640 12,000 19,500 40,000 72,600 115,000 125 44 92 173 355 532 1,020 1,630 2,890 5,890 10,600 17,200 35,400 64,300 102,000 150 40 83 157 322 482 928 1,480 2,610 5,330 9,650 15,600 32,100 58,300 92,300 175 37 77 144 296 443 854 1,360 2,410 4,910 8,880 14,400 29,500 53,600 84,900 200 34 71 134 275 412 794 1,270 2,240 4,560 8,260 13,400 27,500 49,900 79,000 250 30 63 119 244 366 704 1,120 1,980 4,050 7,320 11,900 24,300 44,200 70,000 300 27 57 108 221 331 638 1,020 1,800 3,670 6,630 10,700 22,100 40,100 63,400 350 25 53 99 203 305 587 935 1,650 3,370 6,100 9,880 20,300 36,900 58,400 400 23 49 92 189 283 546 870 1,540 3,140 5,680 9,190 18,900 34,300 54,300 450 22 46 86 177 266 512 816 1,440 2,940 5,330 8,620 17,700 32,200 50,900 500 21 43 82 168 251 484 771 1,360 2,780 5,030 8,150 16,700 30,400 48,100 550 20 41 78 159 239 459 732 1,290 2,640 4,780 7,740 15,900 28,900 45,700 600 19 39 74 152 228 438 699 1,240 2,520 4,560 7,380 15,200 27,500 43,600 650 18 38 71 145 218 420 669 1,180 2,410 4,360 7,070 14,500 26,400 41,800 700 17 36 68 140 209 403 643 1,140 2,320 4,190 6,790 14,000 25,300 40,100 750 17 35 66 135 202 389 619 1,090 2,230 4,040 6,540 13,400 24,400 38,600 800 16 34 63 130 195 375 598 1,060 2,160 3,900 6,320 13,000 23,600 37,300 850 16 33 61 126 189 363 579 1,020 2,090 3,780 6,110 12,600 22,800 36,100 900 15 32 59 122 183 352 561 992 2,020 3,660 5,930 12,200 22,100 35,000 950 15 31 58 118 178 342 545 963 1,960 3,550 5,760 11,800 21,500 34,000 1,000 14 30 56 115 173 333 530 937 1,910 3,460 5,600 11,500 20,900 33,100 1,100 14 28 53 109 164 316 503 890 1,810 3,280 5,320 10,900 19,800 31,400 1,200 13 27 51 104 156 301 480 849 1,730 3,130 5,070 10,400 18,900 30,000 1,300 12 26 49 100 150 289 460 813 1,660 3,000 4,860 9,980 18,100 28,700 1,400 12 25 47 96 144 277 442 781 1,590 2,880 4,670 9,590 17,400 27,600 1,500 11 24 45 93 139 267 426 752 1,530 2,780 4,500 9,240 16,800 26,600 1,600 11 23 44 89 134 258 411 727 1,480 2,680 4,340 8,920 16,200 25,600 1,700 11 22 42 86 130 250 398 703 1,430 2,590 4,200 8,630 15,700 24,800 1,800 10 22 41 84 126 242 386 682 1,390 2,520 4,070 8,370 15,200 24,100 1,900 10 21 40 81 122 235 375 662 1,350 2,440 3,960 8,130 14,800 23,400 2,000 NA 20 39 79 119 229 364 644 1,310 2,380 3,850 7,910 14,400 22,700 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 kPa, 1-inch water column = 0.2488 kPa, 1 British thermal unit per hour = 0.293 1 W, 1 cubic foot per hour = 0.0283 m3/h, 1 degree = 0.01745 rad. Notes: 1. NA means a flow of less than 10 cfh. 2. All table entries have been rounded to three significant digits. Table 402.4(3) Schedule 40 Metallic Pipe Gas Natural Inlet Pressure Less than 2 psi Pressure Drop 3.0 in. w.c. Specific Gravity 0.60 Intended Use: Initial supply pressure of 8.0 inches w.c. or greater Pipe Size (inch) Nominal 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Actual ID 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026 Length (ft) Capacity in Cubic Feet of Gas Per Hour 10 454 949 1,790 3,670 5,500 10,600 16,900 29,800 60,800 20 312 652 1,230 2,520 3,780 7,280 11,600 20,500 41,800 30 250 524 986 2,030 3,030 5,840 9,310 16,500 33,600 40 214 448 844 1,730 2,600 5,000 7,970 14,100 28,700 50 190 397 748 1,540 2,300 4,430 7,070 12,500 25,500 60 172 360 678 1,390 2,090 4,020 6,400 11,300 23,100 70 158 331 624 1,280 1,920 3,700 5,890 10,400 21,200 80 147 308 580 1,190 1,790 3,440 5,480 9,690 19,800 90 138 289 544 1,120 1,680 3,230 5,140 9,090 18,500 100 131 273 514 1,060 1,580 3,050 4,860 8,580 17,500 125 116 242 456 936 1,400 2,700 4,300 7,610 15,500 150 105 219 413 848 1,270 2,450 3,900 6,890 14,100 175 96 202 380 780 1,170 2,250 3,590 6,340 12,900 200 90 188 353 726 1,090 2,090 3,340 5,900 12,000 250 80 166 313 643 964 1,860 2,960 5,230 10,700 300 72 151 284 583 873 1,680 2,680 4,740 9,700 350 66 139 261 536 803 1,550 2,470 4,360 8,900 400 62 129 243 499 747 1,440 2,290 4,060 8,300 450 58 121 228 468 701 1,350 2,150 3,800 7,800 500 55 114 215 442 662 1,280 2,030 3,590 7,300 550 52 109 204 420 629 1,210 1,930 3,410 7,000 600 50 104 195 400 600 1,160 1,840 3,260 6,640 650 47 99 187 384 575 1,110 1,760 3,120 6,360 700 46 95 179 368 552 1,060 1,700 3,000 6,110 750 44 92 173 355 532 1,020 1,630 2,890 5,890 800 42 89 167 343 514 989 1,580 2,790 5,680 850 41 86 162 332 497 957 1,530 2,700 5,500 900 40 83 157 322 482 928 1,480 2,620 5,330 950 39 81 152 312 468 901 1,440 2,540 5,180 1,000 38 79 148 304 455 877 1,400 2,470 5,040 1,100 36 75 141 289 432 833 1,330 2,350 4,780 1,200 34 71 134 275 412 794 1,270 2,240 4,560 1,300 33 68 128 264 395 761 1,210 2,140 4,370 1,400 31 65 123 253 379 731 1,170 2,060 4,200 1,500 30 63 119 244 366 704 1,120 1,980 4,050 1,600 29 61 115 236 353 680 1,080 1,920 3,910 1,700 28 59 111 228 342 658 1,050 1,850 3,780 1,800 27 57 108 221 331 638 1,020 1,800 3,670 1,900 27 56 105 215 322 619 987 1,750 3,560 2,000 26 54 102 209 313 602 960 1,700 3,460 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 kPa, 1-inch water column = 0.2488 kPa, 1 British thermal unit per hour = 0.293 1 W, 1 cubic foot per hour = 0.0283 m3/h, 1 degree = 0.0 1745 rad. Note: All table entries have been rounded to three significant digits. Table 402.4(4) Schedule 40 Metallic Pipe Gas Natural Inlet Pressure Less than 2 psi Pressure Drop 6.0 in. w.c. Specific Gravity 0.60 Intended Use: Initial supply pressure of 11.0 inches w.c. or greater Pipe Size (inch) Nominal 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Actual ID 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026 Length (ft) Capacity in Cubic Feet of Gas Per Hour 10 660 1,380 2,600 5,340 8,000 15,400 24,600 43,400 88,500 20 454 949 1,790 3,670 5,500 10,600 16,900 29,900 60,800 30 364 762 1,440 2,950 4,420 8,500 13,600 24,000 48,900 40 312 652 1,230 2,520 3,780 7,280 11,600 20,500 41,800 50 276 578 1,090 2,240 3,350 6,450 10,300 18,200 37,100 60 250 524 986 2,030 3,030 5,840 9,310 16,500 33,600 70 230 482 907 1,860 2,790 5,380 8,570 15,100 30,900 80 214 448 844 1,730 2,600 5,000 7,970 14,100 28,700 90 201 420 792 1,630 2,440 4,690 7,480 13,200 27,000 100 190 397 748 1,540 2,300 4,430 7,070 12,500 25,500 125 168 352 663 1,360 2,040 3,930 6,260 11,100 22,600 150 153 319 601 1,230 1,850 3,560 5,670 10,000 20,500 175 140 293 553 1,140 1,700 3,280 5,220 9,230 18,800 200 131 273 514 1,060 1,580 3,050 4,860 8,580 17,500 250 116 242 456 936 1,400 2,700 4,300 7,610 15,500 300 105 219 413 848 1,270 2,450 3,900 6,890 14,100 350 96 202 380 780 1,170 2,250 3,590 6,340 12,900 400 90 188 353 726 1,090 2,090 3,340 5,900 12,000 450 84 176 332 681 1,020 1,970 3,130 5,540 11,300 500 80 166 313 643 964 1,860 2,960 5,230 10,700 550 76 158 297 611 915 1,760 2,810 4,970 10,100 600 72 151 284 583 873 1,680 2,680 4,740 9,660 650 69 144 272 558 836 1,610 2,570 4,540 9,250 700 66 139 261 536 803 1,550 2,470 4,360 8,890 750 64 134 252 516 774 1,490 2,380 4,200 8,560 800 62 129 243 499 747 1,440 2,290 4,060 8,270 850 60 125 235 483 723 1,390 2,220 3,920 8,000 900 58 121 228 468 701 1,350 2,150 3,800 7,760 950 56 118 221 454 681 1,310 2,090 3,700 7,540 1,000 55 114 215 442 662 1,280 2,030 3,590 7,330 1,100 52 109 204 420 629 1,210 1,930 3,410 6,960 1,200 50 104 195 400 600 1,160 1,840 3,260 6,640 1,300 47 99 187 384 575 1,100 1,760 3,120 6,360 1,400 46 95 179 368 552 1,060 1,700 3,000 6,110 1,500 44 92 173 355 532 1,020 1,630 2,890 5,890 1,600 42 89 167 343 514 989 1,580 2,790 5,680 1,700 41 86 162 332 497 957 1,530 2,700 5,500 1,800 40 83 157 322 482 928 1,480 2,620 5,330 1,900 39 81 152 312 468 901 1,440 2,540 5,180 2,000 38 79 148 304 455 877 1,400 2,470 5,040 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 kPa, 1-inch water column = 0.2488 kPa, 1 British thermal unit per hour = 0.293 1 W, 1 cubic foot per hour = 0.0283 m3/h, 1 degree = 0.0 1745 rad. Note: All table entries have been rounded to three significant digits. Table 402.4(5) Schedule 40 Metallic Pipe Gas Natural Inlet Pressure 2.0 psi Pressure Drop 1.0 psi Specific Gravity 0.60 Pipe Size (inch) Nominal 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Actual ID 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026 Length (ft) Capacity in Cubic Feet of Gas Per Hour 10 1,510 3,040 5,560 11,400 17,100 32,900 52,500 92,800 189,000 20 1,070 2,150 3,930 8,070 12,100 23,300 37,100 65,600 134,000 30 869 1,760 3,210 6,590 9,880 19,000 30,300 53,600 109,000 40 753 1,520 2,780 5,710 8,550 16,500 26,300 46,400 94,700 50 673 1,360 2,490 5,110 7,650 14,700 23,500 41,500 84,700 60 615 1,240 2,270 4,660 6,980 13,500 21,400 37,900 77,300 70 569 1,150 2,100 4,320 6,470 12,500 19,900 35,100 71,600 80 532 1,080 1,970 4,040 6,050 11,700 18,600 32,800 67,000 90 502 1,010 1,850 3,810 5,700 11,000 17,500 30,900 63,100 100 462 934 1,710 3,510 5,260 10,100 16,100 28,500 58,200 125 414 836 1,530 3,140 4,700 9,060 14,400 25,500 52,100 150 372 751 1,370 2,820 4,220 8,130 13,000 22,900 46,700 175 344 695 1,270 2,601 3,910 7,530 12,000 21,200 43,300 200 318 642 1,170 2,410 3,610 6,960 11,100 19,600 40,000 250 279 583 1,040 2,140 3,210 6,180 9,850 17,400 35,500 300 253 528 945 1,940 2,910 5,600 8,920 15,800 32,200 350 232 486 869 1,790 2,670 5,150 8,210 14,500 29,600 400 216 452 809 1,660 2,490 4,790 7,640 13,500 27,500 450 203 424 759 1,560 2,330 4,500 7,170 12,700 25,800 500 192 401 717 1,470 2,210 4,250 6,770 12,000 24,400 550 182 381 681 1,400 2,090 4,030 6,430 11,400 23,200 600 174 363 650 1,330 2,000 3,850 6,130 10,800 22,100 650 166 348 622 1,280 1,910 3,680 5,870 10,400 21,200 700 160 334 598 1,230 1,840 3,540 5,640 9,970 20,300 750 154 322 576 1,180 1,770 3,410 5,440 9,610 19,600 800 149 311 556 1,140 1,710 3,290 5,250 9,280 18,900 850 144 301 538 1,100 1,650 3,190 5,080 8,980 18,300 900 139 292 522 1,070 1,600 3,090 4,930 8,710 17,800 950 135 283 507 1,040 1,560 3,000 4,780 8,460 17,200 1,000 132 275 493 1,010 1,520 2,920 4,650 8,220 16,800 1,100 125 262 468 960 1,440 2,770 4,420 7,810 15,900 1,200 119 250 446 917 1,370 2,640 4,220 7,450 15,200 1,300 114 239 427 878 1,320 2,530 4,040 7,140 14,600 1,400 110 230 411 843 1,260 2,430 3,880 6,860 14,000 1,500 106 221 396 812 1,220 2,340 3,740 6,600 13,500 1,600 102 214 382 784 1,180 2,260 3,610 6,380 13,000 1,700 99 207 370 759 1,140 2,190 3,490 6,170 12,600 1,800 96 200 358 736 1,100 2,120 3,390 5,980 12,200 1,900 93 195 348 715 1,070 2,060 3,290 5,810 11,900 2,000 91 189 339 695 1,040 2,010 3,200 5,650 11,500 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 kPa, 1-inch water column = 0.2488 kPa, 1 British thermal unit per hour = 0.293 1 W, 1 cubic foot per hour = 0.0283 m3/h, 1 degree = 0.0 1745 rad. Note: All table entries have been rounded to three significant digits. Table 402.4(6) Schedule 40 Metallic Pipe Gas Natural Inlet Pressure 3.0 psi Pressure Drop 2.0 psi Specific Gravity 0.60 Pipe Size (inch) Nominal 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Actual ID 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026 Length (ft) Capacity in Cubic Feet of Gas Per Hour 10 2,350 4,920 9,270 19,000 28,500 54,900 87,500 155,000 316,000 20 1,620 3,380 6,370 13,100 19,600 37,700 60,100 106,000 217,000 30 1,300 2,720 5,110 10,500 15,700 30,300 48,300 85,400 174,000 40 1,110 2,320 4,380 8,990 13,500 25,900 41,300 73,100 149,000 50 985 2,060 3,880 7,970 11,900 23,000 36,600 64,800 132,000 60 892 1,870 3,520 7,220 10,800 20,800 33,200 58,700 120,000 70 821 1,720 3,230 6,640 9,950 19,200 30,500 54,000 110,000 80 764 1,600 3,010 6,180 9,260 17,800 28,400 50,200 102,000 90 717 1,500 2,820 5,800 8,680 16,700 26,700 47,100 96,100 100 677 1,420 2,670 5,470 8,200 15,800 25,200 44,500 90,800 125 600 1,250 2,360 4,850 7,270 14,000 22,300 39,500 80,500 150 544 1,140 2,140 4,400 6,590 12,700 20,200 35,700 72,900 175 500 1,050 1,970 4,040 6,060 11,700 18,600 32,900 67,100 200 465 973 1,830 3,760 5,640 10,900 17,300 30,600 62,400 250 412 862 1,620 3,330 5,000 9,620 15,300 27,100 55,300 300 374 781 1,470 3,020 4,530 8,720 13,900 24,600 50,100 350 344 719 1,350 2,780 4,170 8,020 12,800 22,600 46,100 400 320 669 1,260 2,590 3,870 7,460 11,900 21,000 42,900 450 300 627 1,180 2,430 3,640 7,000 11,200 19,700 40,200 500 283 593 1,120 2,290 3,430 6,610 10,500 18,600 38,000 550 269 563 1,060 2,180 3,260 6,280 10,000 17,700 36,100 600 257 537 1,010 2,080 3,110 5,990 9,550 16,900 34,400 650 246 514 969 1,990 2,980 5,740 9,150 16,200 33,000 700 236 494 931 1,910 2,860 5,510 8,790 15,500 31,700 750 228 476 897 1,840 2,760 5,310 8,470 15,000 30,500 800 220 460 866 1,780 2,660 5,130 8,180 14,500 29,500 850 213 445 838 1,720 2,580 4,960 7,910 14,000 28,500 900 206 431 812 1,670 2,500 4,810 7,670 13,600 27,700 950 200 419 789 1,620 2,430 4,670 7,450 13,200 26,900 1,000 195 407 767 1,580 2,360 4,550 7,240 12,800 26,100 1,100 185 387 729 1,500 2,240 4,320 6,890 12,200 24,800 1,200 177 369 695 1,430 2,140 4,120 6,570 11,600 23,700 1,300 169 353 666 1,370 2,050 3,940 6,290 11,100 22,700 1,400 162 340 640 1,310 1,970 3,790 6,040 10,700 21,800 1,500 156 327 616 1,270 1,900 3,650 5,820 10,300 21,000 1,600 151 316 595 1,220 1,830 3,530 5,620 10,000 20,300 1,700 146 306 576 1,180 1,770 3,410 5,440 9,610 19,600 1,800 142 296 558 1,150 1,720 3,310 5,270 9,320 19,000 1,900 138 288 542 1,110 1,670 3,210 5,120 9,050 18,400 2,000 134 280 527 1,080 1,620 3,120 4,980 8,800 18,000 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 kPa, 1-inch water column = 0.2488 kPa, 1 British thermal unit per hour = 0.293 1 W, 1 cubic foot per hour = 0.0283 m3/h, 1 degree = 0.01745 rad. Note: All table entries have been rounded to three significant digits. Table 402.4(7) Schedule 40 Metallic Pipe Gas Natural Inlet Pressure 5.0 psi Pressure Drop 3.5 psi Specific Gravity 0.60 Pipe Size (inch) Nominal 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Actual ID 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026 Length (ft) Capacity in Cubic Feet of Gas Per Hour 10 3,190 6,430 11,800 24,200 36,200 69,700 111,000 196,000 401,000 20 2,250 4,550 8,320 17,100 25,600 49,300 78,600 139,000 283,000 30 1,840 3,720 6,790 14,000 20,900 40,300 64,200 113,000 231,000 40 1,590 3,220 5,880 12,100 18,100 34,900 55,600 98,200 200,000 50 1,430 2,880 5,260 10,800 16,200 31,200 49,700 87,900 179,000 60 1,300 2,630 4,800 9,860 14,800 28,500 45,400 80,200 164,000 70 1,200 2,430 4,450 9,130 13,700 26,400 42,000 74,300 151,000 80 1,150 2,330 4,260 8,540 12,800 24,700 39,300 69,500 142,000 90 1,060 2,150 3,920 8,050 12,100 23,200 37,000 65,500 134,000 100 979 1,980 3,620 7,430 11,100 21,400 34,200 60,400 123,000 125 876 1,770 3,240 6,640 9,950 19,200 30,600 54,000 110,000 150 786 1,590 2,910 5,960 8,940 17,200 27,400 48,500 98,900 175 728 1,470 2,690 5,520 8,270 15,900 25,400 44,900 91,600 200 673 1,360 2,490 5,100 7,650 14,700 23,500 41,500 84,700 250 558 1,170 2,200 4,510 6,760 13,000 20,800 36,700 74,900 300 506 1,060 1,990 4,090 6,130 11,800 18,800 33,300 67,800 350 465 973 1,830 3,760 5,640 10,900 17,300 30,600 62,400 400 433 905 1,710 3,500 5,250 10,100 16,100 28,500 58,100 450 406 849 1,600 3,290 4,920 9,480 15,100 26,700 54,500 500 384 802 1,510 3,100 4,650 8,950 14,300 25,200 51,500 550 364 762 1,440 2,950 4,420 8,500 13,600 24,000 48,900 600 348 727 1,370 2,810 4,210 8,110 12,900 22,900 46,600 650 333 696 1,310 2,690 4,030 7,770 12,400 21,900 44,600 700 320 669 1,260 2,590 3,880 7,460 11,900 21,000 42,900 750 308 644 1,210 2,490 3,730 7,190 11,500 20,300 41,300 800 298 622 1,170 2,410 3,610 6,940 11,100 19,600 39,900 850 288 602 1,130 2,330 3,490 6,720 10,700 18,900 38,600 900 279 584 1,100 2,260 3,380 6,520 10,400 18,400 37,400 950 271 567 1,070 2,190 3,290 6,330 10,100 17,800 36,400 1,000 264 551 1,040 2,130 3,200 6,150 9,810 17,300 35,400 1,100 250 524 987 2,030 3,030 5,840 9,320 16,500 33,600 1,200 239 500 941 1,930 2,900 5,580 8,890 15,700 32,000 1,300 229 478 901 1,850 2,770 5,340 8,510 15,000 30,700 1,400 220 460 866 1,780 2,660 5,130 8,180 14,500 29,500 1,500 212 443 834 1,710 2,570 4,940 7,880 13,900 28,400 1,600 205 428 806 1,650 2,480 4,770 7,610 13,400 27,400 1,700 198 414 780 1,600 2,400 4,620 7,360 13,000 26,500 1,800 192 401 756 1,550 2,330 4,480 7,140 12,600 25,700 1,900 186 390 734 1,510 2,260 4,350 6,930 12,300 25,000 2,000 181 379 714 1,470 2,200 4,230 6,740 11,900 24,300 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 kPa, 1-inch water column = 0.2488 kPa, 1 British thermal unit per hour = 0.293 1 W, 1 cubic foot per hour = 0.0283 m3/h, 1 degree = 0.0 1745 rad. Note: All table entries have been rounded to three significant digits. 402.4.1 Longest length method. The pipe size of each section of gas piping shall be determined using the longest length of piping from the point of delivery to the most remote outlet and the load of the section. 402.4.2 Branch length method. Pipe shall be sized as follows: 1. Pipe size of each section of the longest pipe run from the point of delivery to the most remote outlet shall be determined using the longest run of piping and the load of the section. 2. The pipe size of each section of branch piping not previously sized shall be determined using the length of piping from the point of delivery to the most remote outlet in each branch and the load of the section. 402.4.3 Hybrid pressure. The pipe size for each section of higher pressure gas piping shall be determined using the longest length of piping from the point of delivery to the most remote line pressure regulator. The pipe size from the line pressure regulator to each outlet shall be determined using the length of piping from the regulator to the most remote outlet served by the regulator. 402.5 Allowable pressure drop. The design pressure loss in any piping system under maximum probable flow conditions, from the point of delivery to the inlet connection of the appliance, shall be such that the supply pressure at the appliance is greater than or equal to the minimum pressure required by the appliance. 402.6 Gas distribution pressures. The maximum design operating pressure for piping systems located inside buildings shall not exceed 1/2 pounds per square inch gauge (psig) (3.5 kPa gauge). Exceptions: 1. Pressure not exceeding 5 psig (34.5 kPa gauge) is permitted where a system supplies one or more appliances that require gas pressure in excess of 1/2 psig (3.5 kPa gauge). 2. Gas pressure not exceeding 15 psig (103.4 kPa gauge) is permitted for appliances in excess of 100,000 cubic feet per hour (2830 m3/h) provided the gas distribution piping is installed as provided for in Section 404. 3. The use of pressure in excess of 15 psig (103.4 kPa gauge) shall be permitted for distribution piping provided all of the requirements of Section 406 and Appendix G are met.

Ask a question about New York law

Corpus searches the New York sections it holds and shows the ones that match, with their citations. Free, no sign-in.