18.71.120 - Materials of construction.
A. General. In addition to the seismic analysis required elsewhere in this chapter, the registered design professional responsible for the seismic analysis of the building shall record the information required by this section on the approved construction documents. B. Information required. The construction documents shall accurately reflect the results of the engineering investigation and design, and show all pertinent dimensions and sizes for plan review and construction. The following shall be provided: 1. The construction documents of the existing construction shall be adequately dimensioned and furnish adequate details in schedules, notes and sections to fully describe the existing building. The construction documents shall include a foundation plan, floor and roof plans which indicate new work, and existing construction; 2. Elevations of the structural system showing sizes and dimensions; 3. Schedules, sections and details showing reinforcement of walls, slabs, beams, joists, girders, columns and foundations. EXCEPTION: If copies of the original construction documents are submitted for information during the plan check, the information required by Subsections 18.71.120.B.1 through 18.71.120.B.3 may be limited to areas of and adjacent to new construction on a complete outline at that level of the building. 4. Sections and details showing attachments and joining of new and existing structures. All reinforcement in the existing structure shall be shown in these sections and details; 5. Specifications and/or general notes fully describing demolition, materials and methods, testing and inspection requirements. C. Registered design professional of record's statement. The responsible registered design professional of record shall state on the approved construction documents the following: 1. "I am responsible for this building's seismic strengthening design in compliance with the minimum seismic resistance standards of Chapter 18.71 of the Long Beach Municipal Code." Or when applicable: 2. "The registered special inspector, required as a condition of the use of structural design stresses requiring continuous inspection, will be responsible to me." TABLE 71-A RATING CLASSIFICATIONS CLASSIFICATION TYPE OF BUILDING CLASSIFICATION | TYPE OF BUILDING Group I | Essential buildings Group II | Buildings with occupant load of 5,000 or more, or assembly rooms of 1,000 occupants or more, and malls as defined elsewhere in the code. Group III | 1,000 to 4,999 occupants Group IV | 300 to 999 occupants Group V | All others TABLE 71-B INITIAL EFFECTIVE MOMENT OF INERTIA OF CONCRETE MEMBERS MEMBER | RANGE Rectangular beams | 0.30 - 0.5 I g T- and L-shaped beams | 0.25 - 0.45 I g Columns P > 0.5 fc' Ag | 0.7 - 0.9 I g Columns P = 0.2 fc' Ag | 0.5 - 0.7 I g Columns P = - 0.05 fc' Ag | 0.3 - 0.5 I g TABLE 71-C ASSUMED YIELD STRESS OF EXISTING REINFORCEMENT TYPE OF REINFORCEMENT AND ERA | ASSUMED YIELD STRESS, ksi Pre-1940 — Structural and intermediate grade, plain and deformed | 45 Pre-1940 — Twisted and hard grade | 55 Post-1940 — Structural and intermediate grade | 45 Post-1940 — Hard grade | 60 ASTM A 615 Grade 40 | 50 ASTM A 615 Grade 60 | 70 For SI: 1 ksi = 6.894 MPa. FIGURE 71-1 RESPONSE SPECTRA SHAPES [image omitted; see the official code]
(ORD-25-0019 § 1(Exh. A), 2025; ORD-22-0033 § 1(Exh. A), 2022; ORD-19-0031 § 1(Exh. A), 2019; ORD-16-0026 § 1(Exh. A), 2016)
Ask a question about Long Beach law
Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.