§ 12.05.011 — International Building Code adopted

City Code of the City of Seward, Alaska (Codified through Ordinance No. 2026-006, enacted July 27, 2026. (Supp. No. 33-1, Update 1)) · Seward City Code § 12.05.011

Corpus is an independent public-information project, not the official City of Seward website. Stable reference: corpuslaw.us/code/5344b338-2a9a-471e-bd41-3f1560a9089d

12.05.011 - International Building Code adopted.

(a) The International Building Code (IBC), 2021 Edition, Chapters 1-12, 14-28, 30-35, and appendix C, are adopted by reference to regulate all occupancies and buildings, except that the IBC is revised by deleting all the references to "ICC Electrical Code" or "NFPA 70" and replacing those references with "Electrical Code as adopted by SCC 12.05.035" and the IBC is revised by deleting all the references to "International Fuel Gas Code", with the exception of Chapter 3 Section 304 and Chapters 6 and 7, deleting all the references to "International Plumbing Code", and replacing the references to "International Fuel Gas Code" and "International Plumbing Code" with "Uniform Plumbing Code as adopted by SCC 12.05.025." Although not published in full in this section, all of the provisions of the International Building Code, 2021 Edition, except as provided in subsection E of this section, shall be and are hereby adopted by reference to the same extent as if set forth in full in this section, except to the extent that the International Building Code shall be in conflict with this code or any relevant ordinance later adopted, in which case the provisions of this code shall prevail. (b) The City of Seward shall possess three copies of the city designated edition of the International Building Code, for public use, inspection and examination, so long as the provisions thereof remain in force: one copy is kept in the Seward City Library (239 Sixth Ave) and two sets are kept at the Seward Fire Station (316 Fourth Ave, Seward, AK 99664). (c) Copies of the International Building Code 2021 Edition (IBC) may be obtained from the International Code Council Inc., 900 Montclair Rd, Birmingham, Alabama 35213; Telephone: (888) 422-7233 or at www.iccsafe.org. (d) It shall be unlawful for any person to erect, construct, enlarge, alter, repair, move, remove, improve, convert, demolish, or equip any building or structure in the city, or cause or permit the same to be done, contrary to or in violation of any of the provisions of the International Building Code adopted and incorporated as the Seward building code by this section. (e) The International Building Code (I.B.C.), 2021 edition, adopted in Subsection A of this section, Chapters 1-12, 14-28, 30-35, and appendix C, are adopted by reference to regulate all occupancies and buildings, with the following revisions: (1) Chapter 1 of the I.B.C. is revised by deleting Sections 104.4, 104.4.4, 101.4.5, 101.4.6, 103, 105.4, 106, 101.4.7, 104.8, 108.4, 107.5, 109.2, 109.4, 109.5, and 110-115; and is revised by deleting the references to the "International Energy Conservation Code (IECC)", "International Property Maintenance Code (IPMC)", "International Private Sewage Disposal Code (IPSDC)", "International Residential Code (IRC)", and "International Wildland-Urban Interface Code (IWUIC)"; (2) Chapter 1, Subsection 101.2 (Scope), the last sentence of the paragraph is revised by adding: "as governed by the provisions of AS 18.70.080"; and the exception is revised to read as follows: "Exceptions: 1. Detached one-, two-, and three-family dwellings. 2. Multiple single-family dwellings (townhouses) not more than three stories above grade plane in height with a separate means of egress and their accessory structures. These structures shall be plan reviewed to the IBC. Fire walls between townhouses may be designed to meet Section 706 of the IBC or by two one-hour fire resistance-rated wall assemblies tested in accordance with Section 703.2.2 of the IBC.; (3) Chapter 1, Subsection 101.4.3 (Plumbing) of the I.B.C. is revised by deleting the reference to the "International Plumbing Code" and replacing it with "Uniform Plumbing Code as adopted by SCC 12.05.025"; (4) Chapter 1, Subsection 102.6 (Existing Structures) of the I.B.C., is revised by deleting the reference to the "International Property Maintenance Code"; (5) Chapter 1, Section 103 (Code Compliance Agency), of the I.B.C. is revised by replacing the existing title "CODE COMPLIANCE AGENCY" with "DUTIES AND POWERS OF THE BUILDING OFFICIAL". (6) Chapter 1, Section 103.1 (Creation of Enforcement Agency), is revised by deleting the entire paragraph and title and replacing it with "GENERAL. The official in charge of enforcing the provisions of this code will be known as the Building Official. The Building Official shall have the authority to render interpretations of this code and to adopt policies and procedures in order to clarify the application of its provisions. Such interpretations, policies and procedures shall be in compliance with the intent and purpose of this code. Such policies and procedures shall not have the effect of waiving requirements specifically provided for in this code." (7) Chapter 1, Section 104.2 (Applications and permits) of the IBC, is revised by deleting the words "and permits" from the heading, and the section is revised to read: "The building official shall receive applications and review construction documents for the on-site erection, alteration, demolition, and moving of buildings and structures and, at the agency's discretion, will inspect the premises to enforce compliance with the provisions of this code. (8) Chapter 1, Subsection 105 (Permits), is revised by deleting the heading and replacing it with "Application for Plan Review"; (9) Chapter 1, Section 105.2 (Work exempt from permit) of the IBC Section 105.2 is also revised by adding a new Item 14 to the Building subsection to read: "14. Buildings classified as a Group U Occupancy, other than those in Appendix LL, that are not offered for use by persons other than the property owner or the owner's employees, not open to the public, and not containing hazardous materials in excess of those found in Tables 307.1(1) and 307.1(2). This exemption includes buildings in which the public has no access, such as farm, dairy operations, or greenhouse operations."; (10) in Chapter 1, Section 105.3 (Application for permit) of the IBC, the first sentence is revised to read: "To obtain a plan review approval, the applicant must first file an application in writing on a form furnished for that purpose by the code enforcement agency."; (11) Chapter 1, Section 107.2.2 (Fire protection system shop drawings) of the IBC, is revised by adding the sentences "Shop drawings shall be sealed by a registered design professional of this state and of appropriate discipline in accordance with AS 08.48, or shall be signed and dated by a fire systems permit holder under AS 18.70.090 and 13 AAC 50.035. At least two sets, one of which may be electronic, of shop drawings shall be submitted. The building official shall retain one set, and one approved set stamped by the building official shall be retained on site during the installation of the system." at the end of the section; (12) Chapter 1, Section 107.3.1 (Approval of construction documents) of the IBC, is revised to read: "One set of bound or one electronic set of construction documents so reviewed shall be retained by the building official."; (13) The Fee for each permit shall be as set forth in Table 1-A. When construction documents are required in accordance with Section 107, a plan review fee equivalent to 65% of the Permit Fee, as shown in Table 1-A, shall be paid. TOTAL VALUATION FEE TABLE 1-A BUILDING PERMIT FEES Total Valuation | Fee $1.00 to $500.00 | $23.50 $501.00 to $2,000.00 | $23.50 for the first $500.00 plus $3.05 for each additional $100.00, or fraction thereof, to and including $2,000.00 $2,001.00 to $25,000.00 | $69.25 for first $2,000.00 plus $14.00 for each additional $1000.00, or fraction thereof, to and including $25,000.00. $25,001.00 to $50,000.00 | $391.25 for the first $25,000.00 plus $10.10 for each additional $1,000.00, or fraction thereof, up to and including $50,000.00 $50,001.00 to $100,000.00 | $643.75 for the first $50,000.00 plus $7.00 for each additional $1,000.00, or fraction thereof, up to and including $100,000.00. $100,001.00 to $500,000.00 | $993.75 for the first $100,000.00 plus $5.60 for each additional $1,000.00, or fraction thereof, up to and including $500,000.00. $500,001.00 to $1,000,000.00 | $3,233.75 for the first $500,000.00 plus $4.75 for each additional $1,000.00, or fraction thereof, up to and including $1,000,000.00. $1,000,001.00 and up | $5,608.75 for the first $1,000,000.00 plus $3.15 for each $1,000.00, or fraction thereof. Other Inspections and Fees 1 Inspections outside of normal business hours .....$47.00 per hour 2 Inspections for which no fee is specifically indicated .....$47.00 per hour 3 Additional plan review required by changes, additions or revisions to plans (minimum charge one-half hour) .....$47.00 per hour 4 For use of outside consultants for plan checking and inspections, or both .....Actual Costs (14) Chapter 1, Section 109.3 (Permit valuations) of the IBC, is revised to read: "Building plan review valuations. The applicant for a plan review involving an addition to an existing structure, a remodel of an existing structure, or a fuel system shall provide an estimated building construction value at the time of application. The valuation shall include the total value of work, including design, materials and labor for which the plan review is being issued. The total value of work must include the electrical, gas, mechanical, and plumbing equipment and permanent systems, including fire protection systems. If, in the opinion of the building official, the valuation is underestimated on the application, the building official shall deny the plan review, unless the applicant can show detailed estimates that meet the approval of the building official. The building official shall set the final building construction valuation. The valuation for all new construction not involving remodel work or additions to existing structures must be based on the valuation schedule established in 13 AAC 50.027."; (15) Chapter 1, Section 107.3.1 (Approval of construction documents) of the I.B.C., is revised to read: "One set of bound construction documents so reviewed shall be retained by the building official."; (16) Chapter 1, Subsection 107.3.4 (General), third paragraph, first sentence of the I.B.C. is revised to read: "Structural observation shall be as required by Section 1709." (17) The Fee for each permit shall be as set forth in Table 1-A. (18) Chapter 1, Section 108.3 (Temporary power) of the I.B.C., is revised by deleting the reference to the "NFPA 70" and replacing it with "Electrical Code as adopted by SCC 12.05.035 "; (19) Chapter 1, Section 113.1 (General) is amended by adding the words "consisting of the City Council of the City of Seward." after the words "hereby created a board of appeals." The period after the word "appeals" is deleted and the third sentence starting with the words "the board of appeals shall...." is deleted in its entirety. The last sentence is also deleted in its entirety. (20) Chapter 1, Section 113.3, (Qualifications) is deleted in its entirety. (21) Chapter 2, Subsection 201.3 (Terms defined in other codes) of the I.B.C. is revised by deleting the references "International Plumbing Code": (22) Chapter 2, Section 202 (Definitions) of the I.B.C. is revised by adding a definition to read: " "EXISTING BUILDING (EXISTING CONSTRUCTION OR EXISTING STRUCTURE). Any building or structure: (A) for which the start of construction commenced before the earlier of: (i) the effective date of the community's first code, ordinance, or standard; or (ii) was erected before December 5, 1956; (B) that received a legal building review. The certificate of fire and life safety or plan review number shall be provided." (23) Chapter 2, Section 202 of the IBC, is revised by adding a definition to read: "BED AND BREAKFAST. A building constructed as a single family home that is the owner's primary residence and contains more than five sleeping rooms, including all sleeping rooms located in cabins on the same property. A bed and breakfast requires a plan review and will be considered a commercial property."; (24) Chapter 2, Section 202 of the IBC, is revised by adding a definition to read: "NONCOMPLIANT OR UN-REVIEWED EXISTING BUILDING. Any building or structure for which the start of construction commenced without a legal plan review after the earlier of (A) the effective date of the community's first code, ordinance, or standard; or (B) December 5, 1956."; (25) Chapter 3, Section 305 (Educational group E) of the I.B.C., is revised by adding a new Section 305.2.4 to read: "305.2.4 Family child care homes. Family child care homes occupied as their primary residence (Group R-3) operating between the hours of 6:00 a.m. and 10:00 p.m. may accommodate a total of 12 children of any age without conforming to the requirements for Group E occupancy, except for fire extinguishers as required by Section 906, smoke alarms as required by Section 907.2.11.2, carbon monoxide alarms as required by Section 908, means of egress requirements of Section 1003, and emergency escape and rescue openings, as required by Section 1029, in napping or sleeping rooms, and fire extinguisher requirements as described in the International Fire Code (IFC), as adopted by reference in 13 AAC 50.025, including children related to the staff. All stories that are not at grade plane shall have access to two exits."; (26) Chapter 3, Section 305.2 (Group E, day care) of the I.B.C., is revised by adding a new exception to read: "Exception: Family child care homes (Group R-3) operating between the hours of 6:00 a.m. and 10:00 p.m. may accommodate a total of 12 children of any age without conforming to the requirements of this regulation (Group E occupancy), except for smoke alarms as described in Subsection 907.2, carbon monoxide detectors and alarms are described in Section 422, means of egress requirements of Section 1003, including emergency escape and rescue openings (as required by Section 1026) in napping or sleeping rooms, and fire extinguisher requirements as described in the International Fire Code; (27) Chapter 3, Section 305 (Educational group E) of the IBC, is revised by adding a new Section 305.4 to read: "305.4 Combination shops. Shop classrooms that combine wood working with any other fabrication using flame or causing spark shall be considered an F-1 occupancy and must be separated from the E occupancy in accordance with Table 602."; (28) I.B.C. Chapter 3, Section 308.2 (Institutional Group I-1) is revised by adding a new paragraph after the first paragraph to read: "Facilities within this occupancy classification that have occupants needing physical assistance to respond in emergency situations must comply with Section 423."; (29) Chapter 3, Section 310.1 (Residential Group R) of the I.B.C., is revised by adding a new paragraph after the first paragraph to read: "For facilities within this occupancy classification that have occupants needing physical assistance to respond in emergency situations, see Section 420."; (30) Chapter 4, Section 406.3.2.1(Dwelling unit separation) of the I.B.C., paragraph 1 is revised by deleting "gypsum board, not less than 1/2 inch (12.7 mm) in thickness" and replacing it with "5/8 inch (15.88 mm) Type X gypsum board"; (31) Chapter 4, Section 412.2.1 (Exterior walls) of the I.B.C., is revised by deleting "30 feet (9 144 mm)" and replacing it with "20 feet (6,098 mm)"; (32) Chapter 4, Section 412.3.1 (Exterior walls) of the IBC, is revised by deleting "30 feet (9144 mm)" and replacing it with "20 feet (6,098 mm)"; (33) Chapter 4, Subsection 415.9.2 of the I.B.C., is revised by deleting the reference to the "International Fuel Gas Code" and replacing it with "Plumbing Code as adopted by SCC 12.05.025"; (34) Chapter 4, Section 415.9.3 of the I.B.C., is revised by deleting the reference to the "International Plumbing Code" and replacing it with "Plumbing Code as adopted by SCC 12.05.025" (35) Chapter 4, Section 415.11.1.8 of the I.B.C. is revised by deleting the reference to the "NFPA 70" and replacing it with "Electrical Code as adopted SCC 12.05.035 ."; (36) Chapter 4 (Special Detailed Requirements Based on Use and Occupancy) of the I.B.C., is revised by adding new Section 42 (Special Security Requirements for Elevated Buildings), and Section 430 (Carbon Monoxide Detectors and Alarms) to read: SECTION 429 SPECIAL SECURITY REQUIREMENTS FOR ELEVATED BUILDINGS 429.1 All elevated buildings with the lower floor level above grade and open on the sides must be fenced around the building exterior or have skirting below the exterior walls to prevent unauthorized access, if a building is higher than two foot to the underside of floor framing. Exceptions: 1. Normally unoccupied buildings; 2. Buildings with F, H, S, and U occupancies. 3. All occupancies within an industrial area that is secured and there is no public access. SECTION CARBON MONOXIDE DETECTORS AND ALARMS 422.1 (Carbon Monoxide Detectors and Alarms) The provisions of this section shall apply to Groups I-1, I-2, and all R occupancies. At least one carbon monoxide detector or alarm shall be installed on each floor level. If a floor level contains bedrooms or sleeping rooms, at least one detector shall be located in the immediate vicinity of the sleeping area, outside of the bedrooms or sleeping rooms. Carbon monoxide detectors and alarms shall be installed in accordance with their listing. The alarm shall be clearly audible in all sleeping rooms, even if the intervening doors are closed. Exceptions: 1 Carbon monoxide detectors and alarms are not required in dwelling units and structures that have no combustion appliances, attached garage, or other vehicle parking within 25 feet of any direct opening. 2 Carbon monoxide detectors and alarms are not required in dwelling units and structures that have only direct vent combustion appliances, and no attached garage, or other vehicle parking within 25 feet of any direct opening. 3 Carbon monoxide detectors and alarms are not required if all combustion equipment is located within a mechanical room separated from the rest of the building by construction capable of resisting the passage of smoke. If the structure has an attached and enclosed parking garage, the garage shall be ventilated by an approved automatic carbon monoxide exhaust system designed in accordance with the International Mechanical Code as adopted in SCC 12.05.031. 422.2 Interconnection. In new construction, all carbon monoxide detectors and alarms located within a single dwelling unit shall be interconnected in such a manner that actuation of one alarm shall activate all of the alarms within the individual dwelling unit. 422.3 Power source. In new construction, carbon monoxide detectors and alarms shall receive their primary power from the building wiring if the wiring is served from a commercial source, and shall be equipped with a battery backup. Wiring shall be permanent and without a disconnecting switch other than what is required for overcurrent protection. In existing construction, carbon monoxide detectors and alarms may be powered by battery or a cord-and-plug with battery backup. (37) Chapter 5 (General), of the I.B.C. is revised by adding a new Section 501.2 to read as follows: "501.2 Location on property. Buildings must adjoin or have access to a permanent public way or yard on not less than one side. Required yards by this section must be permanently maintained."; (38) Chapter 5, Table 509.1 (Incidental uses) of the IBC, is revised by changing the wording in the first block under the left column to read: "Furnace rooms in Group E, I, and R-1, R-2, R-3, and R-4 occupancies regardless of Btu input, and furnace rooms of all other occupancies where the largest piece of equipment is over 400,000 Btu per hour input"; (39) Chapter 7, Section 706.6 of the IBC, is revised by adding a paragraph before the exceptions to read: "If buildings are constructed on pilings, the first floor is above ground, and the area below is completely open to the outside (not affected by skirting), a fire wall may terminate at the first floor level if it complies with the following: 1. The wall must terminate on a structural support that extends completely the length of the wall. 2. The structural support must rest upon and be completely supported by pilings. 3. The rest of the fire wall must comply with IBC Section 706.2. 4. If there is concealed space between the structural supports that are directly supported by piles, the concealed space must have the same fire wall protection rating for the depth of the concealed space."; (40) Chapter 7, Section 718.4.2 (Groups R-1 and R-2) Exception 3 of the IBC, is revised by adding a new sentence at the end of the exception to read: "Adequate cross ventilation must be provided in accordance with Section 1202.2.1."; (41) Chapter 9, Section 901.5 (Acceptance tests) of the IBC, is revised by adding a new sentence at the end of the paragraph to read: "Within 30 days after the completion of the installation, a copy of the acceptance test certificate must be forwarded by the firm conducting the test to the division of fire and life safety or the deferred authority having jurisdiction."; (42) Chapter 9, Section 903.2.3 (Group E) of the IBC, is revised to read: "Group E. An automatic sprinkler system must be provided throughout all buildings with Group E occupancies. The use of a fire wall or barrier does not establish a separate building or fire area for purposes of this section. As determined by the building official, an automatic fire-extinguishing system approved under Section 904 shall be installed in a Group E occupancy in accordance with Section 903.2.3 whenever alterations or additions are made to an existing structure containing a Group E occupancy. Exception: Buildings with Group E occupancies having an occupant load of 50 or less. An automatic sprinkler system must also be provided for every portion of educational buildings below the level of exit discharge. Family child care homes that are licensed to care for more than five persons between the hours of 10:00 p.m. and 6:00 a.m. must be equipped with an automatic sprinkler system designed and installed as described in Section 903.3.1.3 or an equivalent system approved by the building official."; (43) Chapter 9, Section 903.2.8 (Group R) of the IBC, is revised to read: "903.2.8 Group R. An automatic sprinkler system installed in accordance with Section 903.3 shall be provided throughout buildings containing Group R occupancies as provided in this section. 903.2.8.1 Group R-1. An automatic sprinkler system shall be provided throughout all buildings that contain an R-1 occupancy. 903.2.8.2 Group R-2. An automatic sprinkler system shall be provided throughout all buildings that contain an R-2 occupancy. Exceptions: 1. Buildings that are no more than two stories in height, including basements and contain four or fewer dwelling units. 2. Buildings that are no more than two stories in height, including basements and contain 16 or fewer sleeping rooms. For the purpose of this section, fire walls may be used to create up to three separate attached buildings. Any additional buildings must be physically separated in accordance with IBC Table 602. 903.2.8.3 Group R-4. A 13R automatic sprinkler system shall be provided throughout all buildings that contain an R-4 occupancy."; (44) Chapter 9, Subsection 903.3.1.1 of the I.B.C., is revised by adding a new Subsection 903.3.1.1. to read: "Elevator Hoist Ways and Machine Rooms. When the provisions of this code require the installation of automatic sprinkler systems, the installation in elevator hoist ways and machine rooms must occur as described in N.F.P.A. 13-2007, Elevator hoist ways and machine rooms), and adopted by reference, and American Society for Mechanical Engineers (A.S.M.E.) A17.1 Safety Code for Elevators and Escalators as adopted by 8 AAC 77.005, as amended as of June 14, 2006 "; Exception: Sprinklers are not required in an elevator machine room where the machine room is: (1) separated from the remainder of the building as described in Section 3006.4; (2) smoke detection is provided in accordance with N.F.P.A. 72-2007 and adopted by reference: and, (3) notification of alarm activation is received at a constantly monitored location."; (45) Chapter 9, Subsection 903.3.5 (Water supplies) of the I.B.C. is revised by deleting the reference "International Plumbing Code" and replacing it with "Uniform Plumbing Code as adopted by SCC 12.05.025"; (46) Chapter 9, Section 903.3.6 (Hose threads) of the I.B.C., is revised by deleting "the fire code official" and replacing it with "AS 18.70.084"; (47) Chapter 9, Section 904.1 (General) of the IBC, is revised by adding a new sentence at the end of the paragraph to read: "Within 30 days after the completion of the installation, a copy of the acceptance test certificate must be forwarded by the firm conducting the test to the division of fire and life safety or the deferred authority having jurisdiction."; (48) Chapter 9, Subsection 904.3.1 (Electrical wiring) of the I.B.C. is revised by deleting the reference "NFPA 70" and replacing it with "Electrical Code as adopted by SCC 12.05.035; (49) Chapter 9, Section 906.1 (Where required) of the IBC, is revised by deleting the exception in item 1; (50) Chapter 9, Section 907.2.3 (Group E) of the IBC, Exception 1 is revised by replacing "50" with "49"; (51) Chapter 9, Section 907.2.3 (Group E) of the I.B.C., is revised by deleting Exception 3; (52) Chapter 9, Subsection 907.2.3 (Group E) of the I.B.C., is revised by adding a second paragraph to read: "Rooms used for sleeping or napping purposes within a day care use of a Group E occupancy must be provided with smoke alarms that comply with Section 907.2.10.11.2."; (53) Chapter 9, Section 907.2.6.1 (Group I-1) of the I.B.C., is revised by deleting Exception 1; (54) Chapter 9, Subsection 907.2.1 (Single- and multiple-station smoke alarms) of the I.B.C., is revised by adding a second paragraph to read: "When a plan review is required for an existing Group R occupancy, smoke alarms must be installed as described in Section 907.2.11.1."; (55) Chapter 9, Section 907.2.11.5 (Interconnection) of the IBC, is revised by adding a new paragraph to read: "If more than 12 smoke alarms are interconnected the interconnecting means must be supervised in accordance with Electrical Code as adopted by SCC 12.05.035."; (56) Chapter 9, Subsection 907.6.1 (Wiring) of the I.B.C., is revised by deleting the reference "NFPA 70" and replacing it with "Electrical Code as adopted by SCC 12.05.035"; (57) Chapter 9, Section 907.7.2 (Record of completion) of the IBC, is revised by adding a new sentence to read: "Within 30 days after completion of the installation, a copy of record of completion must be forwarded by the firm conducting the acceptance test to the division of fire and life safety or the deferred authority having jurisdiction."; (58) Chapter 9, Subsection 909.12.2 (Wiring) of the I.B.C., is revised by deleting the reference "NFPA 70" and replacing it with "Electrical Code as adopted by SCC 12.05.035"; (59) Chapter 9, Subsection 909.16.3 (Control action and priorities) of the I.B.C exception, is revised by deleting the reference "NFPA 70" and replacing it with "Electrical Code as adopted by SCC 12.05.035"; (60) Chapter 9, Section 909.18 (Acceptance testing) of the IBC, is revised by adding a new sentence at the end of the paragraph to read: "Within 30 days after the completion of the installation, a copy of the acceptance test certificate must be forwarded by the firm conducting the test to the division of fire and life safety or the deferred authority having jurisdiction."; (61) Chapter 10, Subsection 1006.3.3 (Egress based on occupant load) of the I.B.C., is revised by adding an exception to read: "Exception: Basements or the first level below the first story in all occupancies except Group R-3 occupancies, used exclusively for the service of the building, may have access to only one exit. Any other use of the basement, or first level below the first story must have at least two exits arranged as described in Section 1016.2. For purposes of this exception, storage rooms, laundry rooms, maintenance offices, and similar uses may not be considered as providing service to the building."; (62) Chapter 10, Section 1007.1.2 (Three or more exits or exit access doorways) of the I.B.C., is revised by adding an exception to read: "Where access to three or more exits is required, the separation distance of the third exit door or exit access doorway shall not be less than one-third of the length of the maximum overall diagonal dimension of the area served."; (63) Chapter 10, Subsection 1009.3.2 (Stairway width) of the I.B.C., is revised by adding exception 3 to read: "Exception: Stairs or ladders used only to attend equipment are exempt from the requirements of this section."; (64) Chapter 10, Section 1011.7.2 (Outdoor conditions) of the I.B.C., is revised by adding a sentence: "In occupancies other than Group R-3 and Group U occupancies that are accessory to Group R-3 occupancies, surfaces and landings which are part of exterior stairs in climates with snow or ice shall be designed to minimize the accumulation of the snow or ice; (65) Chapter 10, Table 1020.2 (Corridor Fire-Resistance Rating) of the I.B.C., is revised by adding a note to read: "R Occupancies shall be allowed to have a one-hour rated corridor without a sprinkler system when the corridor 1 serves any occupant load greater than 10; 2 serves less than 17 dwelling units; and 3 is less than three stories in height."; (66) Chapter 10, Table 1020.2 [1018.1] (Corridor fire-resistance rating) of the IBC, is revised by inserting a superscript "e" footnote reference after "R" in the "occupancy" column and is revised by adding footnote "e" to read: "R occupancies with an occupant load greater than 10 shall have one-hour rated corridors when the R occupancies are allowed to not have a sprinkler system and 1. serve four or fewer dwelling units or 16 or fewer sleeping rooms; and 2. are not more than two stories."; (67) Chapter 10, Section 1021.1 (General) of the I.B.C., is revised by adding a sentence: "Exterior balconies shall be designed to minimize accumulation of snow or ice that impedes the means of egress."; (68) Chapter 10, Section 1031.2 (Where required) of the IBC, is revised by replacing the first sentence to read: "In addition to the means of egress required by this chapter provisions shall be made for emergency escape and rescue openings in Group R and I-1 occupancies."; (69) Chapter 10, Section 1031.2 (Where required) of the I.B.C., is revised by deleting Exceptions 1 and 3; (70) *Chapter 11, Section 1101.1 (Scope) of the I.B.C., is revised to read: Compliance with the requirements of this chapter and other provisions within this code for accessibility of persons with disabilities is the exclusive responsibility of the owner of the structure or design professional of record."; (71) Chapter 12, Subsection 1202.4.3.2 (Conditioned spaces) of the I.B.C., Exception 4, is revised by deleting "in accordance with the International Energy Conservation Code"; (72) Chapter 12, Subsection 1204.4.1 (Controls) of the I.B.C., is revised by deleting the reference "NFPA 70" and replacing it with "Electrical Code as adopted by SCC 12.05.035"; (73) Chapter 14, Subsection 1404.3 (Vapor retarders) of the I.B.C. is revised by deleting the phrase "The appropriate climate zone shall be selected in accordance with Chapter 3 of the International Energy Conservation Code." And replacing it with, "The appropriate climate zone for the Kenai Peninsula is Climate Zone 7." (74) Chapter 15, Section 1502 (Roof drainage) of the I.B.C., is revised by deleting the reference "International Plumbing Code" and replacing it with "Uniform Plumbing Code as adopted by SCC 12.05.025"; (75) Chapter 16, Section 1601.1 (Scope) of the I.B.C., is revised by adding a second paragraph to read: "This chapter is adopted as design criteria for the structural safety of buildings constructed under this code. Review for conformance with this criteria is not performed by the office of the state fire marshal. The Building Department does not perform review for conformance with these criteria. Compliance with the requirements of this chapter, other provisions in this code for structural design, local government flood reduction ordinances, and federal oversight and authority through the Federal Emergency Management Agency (FEMA) National Flood Insurance Program (NFIP) under C.F.R. 44, Parts 59 - 60, revised is the exclusive responsibility of the building owner or design professional of record." Information regarding the National Flood Insurance Program is available from the Department of Commerce, Community, and Economic Development, division of community and regional affairs at https://www.commerce.alaska.gov/web/dcra/ PlanningLandManagement/FloodplainManagement.aspx. Information on approaches and grants for mitigating natural hazards in construction, including seismic hazards, is available through the Department of Military and Veterans' Affairs, division of homeland security and emergency management at http://www.ready.alaska.gov."; (76) Chapter 16, Subsection 1608.1 of the I.B.C., is revised by deleting "Design snow loads shall be determined in accordance with Section 7 of ASCE 7, but the design roof load shall not be less than that determined by Section 1607" and replacing it with "Design snow loads in the City of Seward shall be no less than 80 pounds/sq. ft.,"; (77) Chapter 17, Subsection 1701.1 (Scope) of the I.B.C., is revised by adding a second paragraph to read: "The provisions of this chapter are adopted as criteria to guide the owner and the registered design professional in meeting the tests and special inspections necessary to assure conformance with the applicable standards adopted under this code. Tests and inspections required by this code are not performed by the Building Department, but are the responsibility of the building owner or design professional of record. The findings of these tests and inspections must be kept for the life of the building."; (78) Chapter 27, Subsection 2701.1 (Scope) of the I.B.C., is revised by deleting the reference "ICC Electrical Code" and replacing it with "Electrical Code as adopted by SCC 12.05.035."; (79) Chapter 27, Section 2701.1 (Scope) of the IBC, is revised by adding a new sentence at the end of the section to read: "Electrical weather heads must be installed on the gable ends when a metal roof is installed."; (80) *Chapter 27, Subsection 2701 (Scope) of the I.B.C., is revised by deleting the reference to the "NFPA 70" and replacing it with "Electrical Code as adopted by SCC 12.05.035"; (81) Chapter 31, Section 3103.1 (Temporary Structures: General) of the I.B.C., the first sentence is revised to read: "The provisions of this section apply in deferred jurisdictions as allowed under 13 AAC 50.075 only, for structures other than tents and membrane structures, erected for a period of less than 180 days."; (82) Chapter 31, Section 3103.2 (Construction documents) of the IBC, is revised by adding a second sentence to read: "Structures of less than 120 square feet in floor area that are designed for the specific purpose of providing an enclosure for non-hazardous equipment, and not containing hazardous materials in excess of those found in Tables 307.1(1) and 307.1(2) are not required to be sealed by a registered design professional."; (83) Chapter 31 of the I.B.C. is revised by deleting Section 3107 (Signs); (84) Chapter 33, Section 3305.1 (Facilities required) of the I.B.C., is revised by deleting the reference to the "International Plumbing Code" and replacing it with "Uniform Plumbing Code as adopted by SCC 12.05.025"; (85) Chapter 35 (Referenced Standards) of the I.B.C. is revised by changing or adding the referenced standards from the publication date listed to the following edition, and the standards are adopted by reference: N.F.P.A. 10-2007 Portable Fire Extinguishers; N.F.P.A. 13-2007 Installation of Sprinkler Systems; N.F.P.A. 13D-2007 Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes; N.F.P.A. 13R-2007 Installation of Sprinkler Systems in Residential Occupancies Up to and Including Four Stories in Height; N.F.P.A. 14-2007 Standpipe and Hose System; N.F.P.A. 20-2007 Installation of Stationary Pumps for Fire Protection; N.F.P.A. 72-2007 National Fire Alarm Code; N.F.P.A. 750-2006 Standards on Water Mist Fire Protection Systems; (86) *Appendix of the I.B.C is revised by adding a new Appendix NN as follows: APPENDIX NN REPAIRS TO BUILDING AND STRUCTURES DAMAGED BY THE OCCURRENCE OF A NATURAL DISASTER" NN 101 Purpose. The purpose of this appendix is to provide a defined level of repair for buildings or structures damaged by a natural disaster in jurisdictions where the governor has declared a formal condition of disaster emergency under AS 26.23 by proclamation. NN 102 General. Required repair levels must be based on the ratio of the estimated value of the repairs required to restore the structural members to their pre-disaster condition to the estimated replacement value of the building or structure. NN 103 Structural repairs. When the ratio described in Section NN 102 does not exceed 10 percent, as determined by design professionals who are professional architects or professional engineers who meet the requirements of AS 08.48 buildings and other structures, except essential facilities included as Category III buildings and structures in Table 1604.5 of this code, must, at a minimum, be restored to their pre-disaster condition. When the ratio described in Section NN 102 is greater than 10 percent but less than 50 percent, buildings and structures, except essential facilities included as Category III buildings and structures in Table 1604.5 of this code, must have the damaged structural members, including all critical ties and connections associated with the damaged structural members, all structural members supported by the damaged member, and all structural members supporting the damaged members repaired and strengthened to bring them into compliance with the force levels and connection requirements of this code. These requirements apply to those essential facilities when the ratio described in Section NN 102 is less than 30 percent. Exception: For buildings or structures with rigid diaphragms where the above-required repair and strengthening increases the rigidity of the resisting members, the entire lateral force-resisting system of the building or structure must be investigated. When, in the opinion of the building official, an unsafe or adverse condition has been created as a result of the increase in rigidity, the condition must be corrected. When the ratio described in Section NN 102 is greater than 50 percent, buildings and other structures, except essential facilities included as Category III buildings and structures in Table 1604.5 of this code, must, at a minimum, have the entire building or structure strengthened to comply with the force level and connection requirements of this code. These requirements apply to essential facilities when the ratio described in Section NN 102 is greater that or equal to 30 percent. NN 104 Nonstructural repairs to light fixtures and suspended ceilings. Under all ratios calculated under NN 102, when light fixtures and the suspension systems of a suspended acoustical ceiling are damaged, the damaged light fixtures and suspension systems must be repaired to fully comply with the requirements of Section 803.9 of this code. Undamaged light fixtures and suspension systems must have the additional support and bracing that is required in Section 803. 10 of this code."; (87) Appendix of the I.B.C. is revised by adding a new APPENDIX PA as follows: "APPENDIX PA OIL AND GAS INDUSTRIAL PROCESSING BUILDINGS PA101 General. These provisions have been established to provide engineering methods for the design and construction of Hydrocarbon Processing Buildings in this state. L102 Scope. These standards supersede the respective requirements of the codes as adopted in SCC 12.05 as the minimum requirements for occupancies when designing and constructing hydrocarbon buildings in this state. L102.2 Small unoccupied structures, shelters, and enclosures, such as a wellhead shelter (any item that is put over the top of the wellhead that totally encloses the wellhead), communications shelters (unoccupied buildings with no hazardous vapors, gases, or products open to the atmosphere within the structure and that is utilized solely for the housing of wires and their components), meter building, and shut-down valve enclosures may be classified as a Group U occupancy if the following conditions are met: 1 The building is less than 1,000 square feet; 2 The contents of the building include only meters, valves, or pipe work; 3 The building is not normally occupied more than once during a 12-hour period; and 4 If the building exceeds 250 square feet, the building has at least two exits. PA103 Basic allowable module size, height, and separation. The basic allowable module size, height, and separation for Hydrocarbon Processing Buildings must comply with Appendix L103.1 - L103.3 of this Code. PA103.1 Area and height. The maximum allowable floor area for Hydrocarbon Processing Buildings using a minimum of Type IIB construction is 10,000 square feet and the building may only be one story. The maximum allowable height shall be 65 feet; the reference datum shall be the top of the first floor framing system. Penthouse and roof structures are permitted to extend above the 65 foot height limit to meet special requirements, including aerial coolers, towers, and tower enclosures. Allowable area and building height increases permitted by Sections 504 and 506 of the I.B.C. do not apply. PA103.1.1 Service area platforms. An elevated platform or series of platforms of Hydrocarbon Processing Buildings may not be classified as a floor or mezzanine within a building, and are not subject to the requirements of Section 505 of the I.B.C. Access and egress requirements for service area platforms must be served by at least two exits per level, with one being directly to an exterior stair. Platforms must be constructed of grating-type material so that the main floor level below is visible through the platform. Upper service area platforms must be kept to the minimum size that is necessary to accomplish occasional service, operating duties, and safe egress. Virtual wall-to-wall grating on upper levels is considered a story and must be included in floor area calculations. PA103.2 Module separation. Hydrocarbon processing buildings must comply with the provisions of Section 501.2 as amended by this code and Sections 704 and 721.6.2.3 of the I.B.C., for all occupancies. Elevated pipe ways extending from a building may not be considered "extensions" of the building. PA103.2.1 Building extensions and service area platforms. Building extensions of Hydrocarbon Processing Buildings into the yard, include landings, platforms, stairs, vessels, vessel enclosures, tanks, and exhaust or intake hoods. Clear and unobstructed access for fire fighting is to be no less than 40 feet. Bridging between buildings must be designed to allow access and operation for firefighting. PA104 Stairs, landings, handrails, and guardrails. Stairs, landings, handrails, and guardrails must meet the minimum requirements of 8 AAC 61, as amended as of March 9, 2001; these regulations supersede the respective requirements of the I.B.C. PA104.1 Floor level at doors. Floors or landings may be more than one inch lower than the threshold of doorways if an attempt is made to minimize the drop through the use of ramps at interior doorways as described in Section 1008.3.1.6 of the I.B.C. PA105 Construction specifics. The construction of Hydrocarbon Processing Buildings must comply with Appendix L105.1 - L105.4 of this Code. PA105.1 Fire walls. When a fire wall is used to qualify under Section 705 of the I.B.C., the wall must comply with that section. If the fire wall does not extend to the ground, the structural supports for the wall must rest upon, and be completely supported by the pilings. PA105.2 Tank support fireproofing. Fire proofing requirements for steel tank supports, as described in Section 3404.2.9.1.3 of the I.F.C. (2006 Edition) as adopted by reference, may be waived by the building official when justified, based on the remoteness of the facility and lack of public access, or analytical or empirical results indicating that sufficient heat could be transmitted to the permafrost to cause foundation settlement. PA105.3 Foam plastic insulated building panels. For hydrocarbon processing buildings used in the actual processing of hydrocarbons and, not normally used in other mineral extraction or manufacturing activities, foam plastic insulated building panels used on these buildings shall apply a foam plastic insulated building panel with a thermal barrier with an index of 15. Factory Mutual approval Standard 4880 or Underwriters Laboratory (UL) Subject 1040 are acceptable tests for the purposes of approval under Section 2603.4 of the I.B.C. PA105.4 Electrical or communication equipment shelters and wellhead shelters. Thermal barrier requirements as described in Section 2603.4 of the I.B.C. are not required for fiberglass or metal sheeting used for construction of electrical or communication equipment shelters and wellhead shelters if the following conditions are met: 1 Foam used must meet the requirements described in Section 2603.3 of the I.B.C.; 2 The area of an individual shelter may not exceed 1,000 square feet; 3 Separation between individual shelters must be a minimum of six feet; 4 Each wellhead shelter shall only enclose one wellhead; 5 The electrical or communication shelter or wellhead shelter must normally be unoccupied. It is understood that operators need to spend approximately 10 minutes per day taking readings in wellhead shelters and that maintenance is infrequently required. The most extensive maintenance is well wireline work. This work may extend to a week per well and occur once every several year per well. Most of this work is accomplished from outside the wellhead shelter. All maintenance is strictly controlled with a permit system; 6 The electrical or communication shelters designed with workstations in the facility do not qualify for this modification. PA106 Fire suppression. The provisions in Sections L106.1 - L106.3 establish the standards for fire suppression at Oil and Gas Hydrocarbon Processing Buildings. PA106.1 Alternate Automatic Fire-Extinguishing (AAFE) system automatic activation for gas detection. In areas of Hydrocarbon Processing Buildings where (1) both fire and explosion hazards exist, (2) both fire and gas detection systems are installed, (3) the fire and gas detection devices alarm at a continuously staffed control room and trained operators can quickly respond to the fire and gas alarms following specific fire and gas alarm response procedures, and (4) collateral fire damage is likely to be minimal, the following (AAFE) operating activation mode is acceptable: Automatic activation of the (AAFE) system upon gas detection coupled with manual activation of the same (AAFE) system on fire detection. PA106.2 Manual activation of total flooding fire suppression systems. In areas where (1) the only hazard is fire, not explosion, (2) fire detection devices alarm at continuously staffed control rooms, (3) trained operators can quickly respond to the fire alarms following specific fire alarm response procedures, and (4) collateral fire damage is likely to be minimal, manual activation of the total flooding fire suppression agent is acceptable. These areas also include continuously staffed control rooms. PA106.3 Platform width. In buildings protected with fire sprinkler systems, any platform that exceeds four feet in width or length is considered an obstruction for the purposes of the installation of sprinkler systems under Section 903.3.1.1 of the I.B.C.".

(Ord. 2008-010, § 2, 2008; Ord. No. 2023-020, § 1, 9-11-2023)

Ask a question about Seward law

Corpus searches the Seward sections it holds and shows the ones that match, with their citations. Free, no sign-in.