For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12.05.021 — International Residential Code adopted

City Code of the City of Seward, Alaska (Codified through Ordinance No. 2026-006, enacted July 27, 2026. (Supp. No. 33-1, Update 1)) · Seward City Code § 12.05.021

Corpus is an independent public-information project, not the official City of Seward website. Stable reference: corpuslaw.us/code/6b08a1b0-87fc-49d0-b4a9-4c547041cce3

12.05.021 - International Residential Code adopted.

A. The International Residential Code, 2021 Edition, approved and published by the International Code Council (Consisting of the Building Officials Code Administrators (BOCA); the International Conference of Building Officials (ICBO), and the Southern Building Code Congress International, Inc. (SBCCI)), is hereby designated and shall be known as the Seward residential code and shall constitute the laws of the city relating to residential building regulation. Although not published in full in this section, all of the provisions of the International Residential Code, 2021 Edition, except as provided in subsection D. of this section, shall be and are hereby adopted by reference to the same extent as if set forth in full in this section except to the extent that the International Residential Code shall be in conflict with this code or any relevant ordinance later adopted, in which case the provisions of this code shall prevail. B. The City of Seward shall possess three copies of the city designated edition of the International Residential Code, for public use, inspection and examination, so long as the provisions thereof remain in force. C. The International Residential Code (IRC) is adopted to regulate all residential occupancies and buildings in the City of Seward. It shall be unlawful for any person to erect, construct, enlarge, alter, repair, move, remove, improve, convert, demolish, or equip any building or structure in the city, or cause or permit the same to be done, contrary to or in violation of any of the provisions of the International Residential Code adopted and incorporated as the Seward residential building code by this section. See Section R105.2 for Work Exempt From Permit. D. The International Residential Code (IRC), 2021 Edition, adopted in subsection A of this section, is hereby amended by adopting the following revisions and exceptions to the I.R.C.: The IRC is revised by deleting all references to the "International Fuel Gas Code", with the exception of chapter 6 and 7 and all references to the "International Plumbing Code" and replacing them with "Uniform Plumbing Code as adopted by SCC 12.05.025". (1) Chapter 1, Section R101.1, of the I.R.C. is revised by inserting "City of Seward" as "name of jurisdiction." (2) Chapter 1, Section R102.7, of the I.R.C. is revised by deleting the words "the International Property Maintenance Code or". (3) Chapter 1, Section R103, of the IRC is revised by replacing the existing title "DEPARTMENT OF BUILDING SAFETY" with "BUILDING DEPARTMENT". (4) Chapter 1, Section R103.1 CREATION OF ENFORCEMENT AGENCY, is revised by deleting the entire paragraph and title and replacing it with "GENERAL. The official in charge of enforcing the provisions of this code will be known as the Building Official. The Building Official shall have the authority to render interpretations of this code and to adopt policies and procedures in order to clarify the application of its provisions. Such interpretations, policies and procedures shall be in compliance with the intent and purpose of this code. Such policies and procedures shall not have the effect of waiving requirements specifically provided for in this code." (5) Chapter 1, Section R105.3.1.1, (Determination of substantially improved or substantially damaged existing building in flood hazard areas), is revised by deleting "Table R301.2" and inserting the words "City of Seward Ordinance Section 9.15.140." (6) Chapter 1, Section R106.1.4, (Information for construction in flood hazard areas), is revised by deleting "Table R301.2" and inserting the words "City of Seward Ordinance 15.25". (7) Chapter 1, Section R108.2, (Schedule of permit fees), is amended by deleting everything after "in accordance with " and inserting the words "Table 1-A, Building Permit Fees" and inserting Table 1-A in the text. TABLE 1-A BUILDING PERMIT FEES Total Valuation | Fee $1.00 to $500.00 | $23.50 $501.00 to $2,000.00 | $23.50 for the first $500.00 plus $3.05 for each additional $100.00, or fraction thereof, to and including $2,000.00. $2,001.00 to $25,000.00 | $69.25 for first $2,000.00 plus $14.00 for each additional $1,000.00, or fraction thereof, to and including $25,000.00. $25,001.00 to $50,000.00 | $391.25 for the first $25,000.00 plus $10.10 for each additional $1,000.00, or fraction thereof, up to and including $50,000.00. $50,001.00 to $100,000.00 | $643.75 for the first $50,000.00 plus $7.00 for each additional $1,000.00, or fraction thereof, up to and including $100,000.00. $100,001.00 to $500,000.00 | $993.75 for the first $100,000.00 plus $5.60 for each additional $1,000.00, or fraction thereof, up to and including $500,000.00. $500,001.00 to $1,000,000.00 | $3,233.75 for the first $500,000.00 plus $4.75 for each additional $1,000.00, or fraction thereof, up to and including $1,000,000.00. $1,000,001.00 and up | $5,608.75 for the first $1,000,000.00 plus $3.15 for each $1,000.00, or fraction thereof. Other Inspections and Fees 1. Inspections outside of normal business hours, per hour .....47.00 2. Inspections for which no fee is specifically indicated, per hour .....47.00 3. Additional plan review required by changes, additions or revisions to plans (minimum charge - one-half hour), per hour .....47.00 4. For use of outside consultants for plan checking and inspections, or both .....Actual costs (8) Chapter 1, Section R111, (Service utilities), is deleted in its entirety. (9) Chapter 1, Section R112.1 (General), is amended by adding the words "consisting of the City Council of the City of Seward." after the words in the first sentence "hereby created a board of appeals." The period after the word "appeals" is deleted and the third sentence starting with the words "the board of appeals shall...." is deleted in its entirety. (10) Chapter 1, Section R112.3, (Qualifications), is amended by deleting the entire paragraph and title. (11) Chapter 3, Table R301.2, (Climatic and geographic design criteria), TABLE R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Add the following information in the table: Roof Snow Load | 80 psf Uniform Roof Snow Load | 80 psf Wind Speed | 100 mph Seismic Design Category | D 2 Weathering | Severe Frost Line Depth | 42 inches Termite | None - Slight Winter Design Temp. | -20 Degrees F Ice Barrier Underlayment required | Yes Flood Hazards | Yes, see Flood Hazards Maps Air Freeze Index | 1673 Mean Annual Temp. | 39 Degrees F Decay | Slight - Moderate (12) Chapter 3, Section R301.1.4 (Intermodal shipping containers), is deleted in its entirety. (13) Chapter 3, Section R302.5.1 (Opening protection) is amended by adding a sentence at the end of the section "All door openings between garage and residence must be equipped with smoke gaskets." (14) Chapter 3, Section R302.6 (Dwelling-garage fire separation) is amended by changing the first sentence to read "The garage shall be separated from the residence by a minimum of one hour occupancy separation" and delete the last sentence and Table R302.6. (15) Chapter 3, Section R302.7 (Under-stair protection) is amended by replacing ½-inch (12.7mm) with "⅝-inch" (16) Chapter 3, Section R313.1 (Townhouse automatic fire sprinkler system) is amended by at the end of the sentence adding; "that exceeds a total of 3600 square feet per unit or as required by the International Fire Code as adopted". (17) Chapter 3, Section R313.2 (One- and two-family dwellings automatic sprinkler systems) is amended by deleting the section, including R313.2.1 and exception. (18) Chapter 3, R315.2.1 (New construction) is amended by deleting the current text and replacing it with, "In new construction, carbon monoxide alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery back-up. Wiring shall be permanent and without disconnecting switch other than those required for overcurrent protection. In existing construction, carbon monoxide detectors shall be permitted to be battery powered or cord-and-plug type with battery backup." (19) Chapter 3, Section R317.3.1 (Fasteners for preservation-treated wood) is amended by deleting the exceptions. (20) Chapter 3, section R322.1 (General) is amended by replacing the words "in Table 301.2" with the words "by the City of Seward Flood Zone Maps". (21) Chapter 3 Section 322.1.7(Protection of water supply and sanitary sewage systems), in the last sentence, delete everything after "plumbing provisions of this code" and insert a period after "code". (22) Chapter 4, Section R401.1 (Application) is amended by deleting "Table R301.2" and replacing it with "City of Seward Flood Zone Maps". (23) Chapter 4, Section R401.2 REQUIREMENTS. Add a new sentence to the end of the paragraph that states, "Wood foundations shall have a minimum 16-inch x 10-inch reinforced concrete footing." (24) Chapter 4, Section R402.1 (Wood foundations) is amended by adding a new subsection, R402.1.3 (Restraint for wood foundation) that states: "Basement. A 4-inch thick concrete slab poured against the studs. If a wooden screed is used, it shall be pressure treated Douglas fir or hem fir. Option 1: A minimum 5-inch wide by 4-inch deep concrete curb poured against the inside face of the studs. The kicker shall be reinforced with a continuous horizontal No. 3 reinforcing bar. If the kicker is not poured with the continuous concrete footing, it may be poured later provided vertical #3 reinforcing bars x 10 inches long shall be cast into the footing at 2 feet on center. They shall extend 2 inches above the top of the footing. The continuous #3 bar shall be secured to the vertical #3 bars. Option 2: Installation of preservative treated 4" x 4"s with a minimum ½" x 12" galvanized anchor bolts at 24" O.C. installed in footing against the inside face of studs along the entire perimeter. Exception: The above need not apply if a suitable alternate design is prepared by an engineer registered in the State of Alaska and is approved by the Building Official." (25) Chapter 4, Section R403.1.6.1 (Foundation anchorage in seismic design categories C, D0, D1 and D2) is amended by changing the anchor bolt spacing in item #2 and #3 from "not more than 6 feet" to read "not more than 4 feet". (26) Chapter 4, Section 403.2 (Footings for wood foundations). Strike current paragraph and replace with the following sentence: "Footings for wood foundations shall be in accordance with the requirements of Section 401.2. (27) Chapter 4, Section R404 is amended by removing all references to Masonry or CMU foundation walls. Masonry or CMU walls shall not be allowed for use in residential foundations. (28) Chapter 4, Section R404.1 (Concrete and masonry foundation walls) is deleted in its entirety. (29) Chapter 4, Section R404.1.1, (Masonry foundation walls), is deleted in its entirety. (30) Chapter 4, Section R404.1.2, (Concrete foundation walls), is deleted in its entirety. (31) Chapter 4, Section R404.1.3, (Design required) is deleted in its entirety. (32) Chapter 4, Section R404.1.4 (Seismic design categories D1 and D2), is deleted in its entirety. (33) Chapter 4, Table R404.1.1(1), (Plain concrete and plain masonry foundation walls) , is deleted in its entirety. (34) Chapter 4, Table R404.1.1(2), (Reinforced concrete and masonry foundation walls), is deleted in its entirety. (35) Chapter 4, Table R404.1.1(3), (Reinforced concrete and masonry foundation walls), is deleted in its entirety. (36) Chapter 4, Table R404.1.1(4), (Reinforced concrete and masonry foundation walls), is deleted in its entirety. (37) Chapter 4, Section R404.3, (Wood sill plates), is amended by deleting the paragraph and substituting it with the following: Wood sill plates shall be minimum 2-inch by 6-inch nominal lumber and shall be bolted to the foundation or foundation wall with not less than ten (10) inch by five-eights (⅝) inch nominal diameter galvanized steel bolts embedded at least seven (7) inches into the concrete or in fully grouted cells of reinforced masonry and spaced not more than four (4) feet zero (0) inches apart. There shall be a minimum of two bolts per piece with one bolt located within 12 inches of each end of each piece. Washers shall be galvanized and in accordance with R602.11.1. Wood sill plates must be preservative-treated material as specified in Section R317.1. (38) A new section, Chapter 4, Section R404.3.1 is created as, (Reinforced concrete). 1. The minimum reinforcement for reinforced concrete shall be as follows: 12" Walls | 10" Walls #4 @ 12" o.c. each face horizontal | #4 @ 8" o.c. horizontal #4 @ 18" o.c. each face vertical | #4 @ 12" o.c. vertical 8" Walls | 6" Walls #4 @ 10" o.c. horizontal | #4 @ 12" o.c. horizontal #4 @ 16" o.c. vertical | #4 @ 18" o.c. vertical 2. Reinforced concrete walls shall be anchored to all floors and roofs in accordance with Chapter 16 and 19 of the International Building Code, as adopted in SCC 12.05.011. 3. All intersecting reinforced concrete walls shall be tied together. 4. All interior and exterior concrete walls shall be reinforced. 5. All structural members framing into or supported on concrete walls or columns shall be anchored. ALTERNATE REINFORCEMENT FOR CONCRETE WALLS 6" Walls | #4 @ 12" hor. | #3 @ 8" hor. | #5 @ 13" hor. #4 @ 18" vert. | #3 @ 12" vert. | #5 @ 18" vert. 8" Walls | #4 @ 10" hor. | #3 @ 5½" hor. | #5 @ 15" hor. #4 @ 16" vert. | #3 @ 9" E.F. vert. | #5 @ 18" vert. 10" Walls | #4 @ 8" hor. | #3 @ 9" E.F. hor. | #5 @ 12" hor. #4 @ 12" vert. | #3 @ 15" E.F. vert. | #5 @ 18" vert. 12" Walls | #4 @ 12" E.F. hor. | #3 @ 7½" E.F. hor. | #5 @ 18" E.F. hor. #4 @ 18" E.F. vert. | #3 @ 12" E.F. vert. | #5 @ 18" E.F. vert. (E.F. -Each Face-double row of bars) (39) Chapter 4, Figure 404-31, TYPICAL FOUNDATION AND FOOTING DEPTH, is added as shown: [image omitted; see the official code] (40) Chapter 4, Figure 404-31, TYPICAL PONY WALL FOR SPLIT LEVEL, is added as shown: [image omitted; see the official code] (41) Chapter 4, Figure 404-37, TYPICAL BASEMENT FOUNDATION WALL, is added as shown: [image omitted; see the official code] (42) Chapter 4, Section R406.3.2, (Below grade moisture barrier), delete the existing paragraph and substitute the following: "Foundation walls located below grade shall be damp proofed with either 2-ply of 15 lb. hot-mopped felt, or 1-ply of 30 lb hot-mopped felt, Bituthane or other approved materials." (43) A new section, Chapter 6, Section R601.3 (Moisture control), is added, "In all framed walls, floors and roof/ceiling comprising elements of the building thermal envelope, a vapor retarder shall be installed on the warm-in-winter side of the insulation." (44) Chapter 6, Section R602.3.2, (Top plate), is amended by deleting the exceptions. (45) Chapter 7, Section R702.7 (Vapor retarders), is amended by deleting the words "interior side of frame walls" and replacing it with "warm in the winter side of the insulation," and by adding the following at the end of the first paragraph, "In all framed walls, floors and roof/ceiling comprising elements of the building thermal envelope, a vapor retarder shall be installed on the warm-in-winter side of the insulation." (46) Chapter 8, Section R802.10.3, (Bracing), is amended by adding the following details and verbiage to the section: [image omitted; see the official code] [image omitted; see the official code] Other configurations may be deemed acceptable when supported by calculations. (47) Chapter 8, R807.1, (Attic access), is amended by adding the following to the end of the first paragraph: "Attic access shall not be located in a room containing bathing facilities. (48) Chapter 9, R903.4, (Roof drainage), is amended by adding the following sentence after the first sentence: Roofs and gutter downspouts shall not create a water flow that damages neighboring properties. (49) Chapter 9, Section R905.1 (Roof covering application), is amended by adding a new sentence at the end of the paragraph: "All roof coverings shall be fastened to ⅝" minimum solidly sheathed decks". (50) Chapter 9, Section R905.2.2 SLOPE, is amended by deleting the entire section and replacing it with the following: "Asphalt shingles shall only be used on roof slopes of three units vertical in 12 units horizontal or greater. Underlayment shall be in accordance with Section R905.2.7 and ice protection shall be in accordance with R905.2.7.1." (51) Chapter 9, Section 905.1.1 (Underlayment), Table R905.1.1(2) UNDERLAYMENT APPLICATION is amended by deleting the words, in each place it is found, " Underlayment shall be a minimum of two layers applied in the following manner: apply 19-inch strip of underlayment felt parallel to and starting at the eave. Starting at the eave, apply 36-inch wide sheets of underlayment, overlapping successive sheets 19 inches. Distortions in the underlayment shall not interfere with the ability of the shingles to seal. End laps shall be 4 inches and shall be offset by 6 feet." and replace with: "......underlayment shall be ice and water shield adhesive type of membrane covering the entire roof." (52) Chapter 9, Section R905. 1.1 (Underlayment), Table R905.1.1(2) UNDERLAYMENT APPLICATION is amended by deleting the paragraphs under the column "Areas where wind design is not required in accordance with Figure R301.2.1" and in the "Asphalt Shingles," "Clay and concrete tile" and Photovoltaic Shingles" rows, the Table cell text will be deleted and replaced with the following: "For roof slopes from 2 units vertical in 12 units horizontal (2:12), underlayment shall be two layers applied in the following manner: apply a 19-inch strip of underlayment felt parallel to and starting at the eaves. Starting at the eave, apply 36-inch-wide sheets of underlayment, overlapping successive sheets 19 inches. Distortions in the underlayment shall not interfere with the ability of the shingles to seal. End laps shall be 4 inches and shall be offset by 6 feet. For roof slopes of 4 units vertical in 12 units horizontal (4:12) or greater, underlayment shall be one layer applied in the following manner: underlayment shall be applied shingle fashion, lapped 4 inches over ice protection. Lap subsequent layers 2 inches horizontally and 4 inches vertically to shed water continuing to the ridge, fastened sufficiently in place. Ice protection shall be in accordance with R905.2.7"(54) Chapter 9, Section R905.4, (Metal roof shingles), is amended by deleting subsections R905.4.1 through R905.4.3 and replacing 905.4.1 with, "Refer to R905.1, R905.2.2, and R905.2.7". (53) Chapter 9, Section R905.4, (Metal roof shingles), is amended by deleting subsections R905.4.1 through R905.4.3 and replacing 905.4.1 with, "Refer to R905.1, R905.2.2, and R905.2.7" . (54) Chapter 9, Section R905.5, (Mineral-surfaced roll roofing), is amended by deleting subsections R905.5.1 through R905.5.3 and replacing 905.5.1 with "Refer to R905.1; R905.2.2; and R905.2.7." . (55) Chapter 9, Section R905.6, (Slate shingles), is amended by deleting subsections R905.6.1 through R905.6.3 and replacing 905.6.1 with "Refer to R905.1; R 905.2.2 and R905.2.7." . (56) Chapter 9, Section R905.7, (Wood shingles), is amended by deleting subsections R905.7.1 through R905.7.7 and replacing it with "Refer to R905.1; R905.2.2; and R905.2.7." . (57) Chapter 9, Section R905.8, (Wood shakes), is amended by deleting subsections R905.8.1 through R905.8.8 and replacing it with "Refer to R905.1; R905.2.2; and R9052.7." (58) Chapter 9, Section R905.9.1, (Slope), is amended by deleting the words: "…except for coal-tar built-up roofs, which shall have a design slope of a minimum one-eighth unit vertical in 12 units horizontal (1-percent slop")." (59) Chapter 9, Section R905.10, (Metal roof panels), is amended by deleting subsections R905.10.1 through R905.10.2 and replacing it with "Refer to R905.1; R905.2.2; and R905.2.7." (60) Chapter 9, Section R905.10.2, (Slope) is amended by adding the following as the fourth paragraph: "4. Install underlayment under all metal roof panels. Underlayment shall be one layer of Type 15 felt. Underlayment shall be installed, starting with 4-inch lap-over ice protection. Each subsequent layer shall be lapped 2 inches horizontally, and 4-inch vertically to shed water continuing to the ridge. Fasten sufficiently to hold in place. Ice protection shall be in accordance with R905.2.7.1". (61) Chapter 11, ([Re] Energy efficiency), is amended by deleting the chapter in its entirety and replace it with the following: "Chapter 11, Energy Efficiency. All one- and two-family dwellings and townhouses shall comply with the following insulation standards." Minimum Insulation R-Value [(hrft2degF)/Btu] Minimum Glazing U-Factor | Ceilings | Walls | Basement Walls | Crawlspace Walls | Exposed Floors Above Grade (Cantilevered Floors) Minimum R-Value | 0.35 | R-38 | R-19 | R-19 | R-19 | R-30 (62) Chapter 13, Section M1301.1 (Scope) is amended by deleting the last sentence that begins with "Installations of mechanical appliances..." (63) Chapter 13, Section M1307.2 (Anchorage of appliances) is amended by adding the sentence in between the first and second sentences, "Boilers shall be secured to resist earthquake motion by anchoring boiler and stand to wall or floor."

(Ord. 2008-012, § 1, 2008; Ord. No. 2013-007, § 1, 9-9-2013; Ord. No. 2023-020, § 1, 9-11-2023)

Ask a question about Seward law

Corpus searches the Seward sections it holds and shows the ones that match, with their citations. Free, no sign-in.