For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.25.050 — Provisions for flood hazard reduction

City Code of the City of Seward, Alaska (Codified through Ordinance No. 2026-006, enacted July 27, 2026. (Supp. No. 33-1, Update 1)) · Seward City Code § 15.25.050

Corpus is an independent public-information project, not the official City of Seward website. Stable reference: corpuslaw.us/code/3134baa8-712e-4714-bc33-3b335e773bcd

15.25.050 - Provisions for flood hazard reduction.

A. Standards of construction. In all special flood hazard areas, the following standards are required: 1. Alteration of watercourses. a. The flood carrying capacity within the altered or relocated portion of said watercourse must be maintained; and b. Maintenance must be provided within the altered or relocated portion of said watercourse to ensure that the flood carrying capacity is not diminished; and c. Conditions as stated in 15.25.040(B)(3)(b) and 15.25.040(B)(3)(c) must be met. 2. Anchoring. All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. 3. Construction materials and methods. a. All new construction and substantial improvements shall be constructed with materials resistant to flood damage; b. All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage; and c. All new construction and substantial improvement shall be constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. d. Within Zones AH or AO, adequate drainage paths shall be constructed around structures on slopes to guide floodwaters around and away from proposed structures. 4. Elevation and floodproofing. a. Residential construction. 1. For A Zones (A, AE, A1-30, AH, AO). Residential construction, new or substantial improvement, shall have the lowest floor, including basement, elevated to or above the Base Flood Elevation. i. In a Zone AO, the Base Flood Elevation is determined from the FIRM panel as the depth number specified. If no depth is specified, the required elevation is at minimum two feet above highest adjacent grade. ii. In a Zone A where the base flood elevation has not been determined, the base flood elevation is determined locally by the criteria set out in Section 15.25.040(B)(2). A minimum of two feet above highest adjacent grade may result in a lower insurance premium. iii. In Zones AE, A1-30, and AH, the base flood elevation is determined from the FIS and/or FIRM. iv. A garage attached to a residential structure, constructed with the garage floor slab below the base flood elevation, must be designed to allow for the automatic entry and exit of flood waters. See section 15.25.050(A)(3)(d). Upon completion of the structure, certification by a registered professional engineer or surveyor that the elevation requirements of the lowest floor, including basement, of this section have been satisfied shall be provided to the floodplain administrator for verification. 2. For V Zones (VE, V1-30 and V). Residential construction, new or substantial improvement, shall: i. Be located landward of the reach of mean high tide; ii. Have the bottom of the lowest structural member of the lowest floor (excluding pilings and columns), elevated to or above the base flood elevation; iii. Have the pile or column foundation and structure attached thereto be anchored to resist flotation, collapse and lateral movement due to the effects of wind and water loads acting simultaneously on all building components. Water loading values used shall be those associated with the base flood. Wind loading values used shall be those required by applicable State or local building standards. Construction of structures with timber piling, posts, or piers as the sole structural support, is prohibited except for docks, wharves, and other engineered stand-alone structures expressly approved by the building official in accordance with the International Building Code as adopted by the city. iv. Have the space below the lowest floor, usable solely for parking of vehicles, building access, or storage, either free of obstruction or constructed with non-supporting breakaway walls, open wood lattice-work, or insect screening intended to collapse under wind and water loads without causing collapse, displacement, or other structural damage to the elevated portion of the building or supporting foundation system. For the purposes of this section, a breakaway wall shall have a design safe loading resistance of not less than ten and no more than 20 pounds per square foot; v. Prohibit the use of fill for structural support of buildings; and vi. Prohibit human-made alteration of sand dunes and mangrove stands. A registered professional engineer or architect shall develop or review the structural design, specifications and plans for the construction, and shall certify that the design and methods of construction to be used are in accordance with accepted standards of practice for meeting the provisions of this section. Upon completion of construction, certification by a registered professional engineer or architect that these design standards have been satisfied, and certification by a registered professional engineer or surveyor that the elevation requirements of the bottom of the lowest structural member of the lowest floor, excluding pilings and columns, of this section have been satisfied shall be provided to the floodplain administrator for verification. b. Non-residential construction. For A Zones (A, AE, A1-30, AH, AO): Non-residential construction, new or substantial improvement, shall have the lowest floor either elevated to conform with section 15.25.050(A)(3)(a) subsections (i), (ii) or (iii) as appropriate, or, together with attendant utility and sanitary facilities, i. Be floodproofed below the elevation recommended under section 15.25.050(A)(3)(a) subsections (i), (ii) or (iii) as appropriate so that the structure is watertight with walls substantially impermeable to the passage of water; and ii. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. iii. A registered professional engineer or architect shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice meeting the provisions listed above. Upon completion of the structure, certification by a registered professional engineer or surveyor that the elevation requirements of the lowest floor, including basement, of this section have been satisfied shall be provided to the floodplain administrator for verification; or certification by a registered professional engineer or architect that the floodproofing design of this section is satisfied, including the specific elevation in relation to mean sea level to which such structures are floodproofed, shall be provided to the floodplain administrator for verification. For V Zones (VE, V1-30, V). Floodproofing of non-residential structures is prohibited. All structures must be elevated and constructed according to the requirements set forth in section 15.25.050(A)(3)(a). c. Appurtenant structures (detached garages and storage structures). 1. For A Zones (A, AE, A1-30, AH, AO). a. Appurtenant structures used solely for parking of vehicles or storage may be constructed such that the floor is below the base flood elevation, provided the structure is designed and constructed in accordance with the following requirements: i. Use of the appurtenant structure must be limited to parking of vehicles or storage; ii. The portions of the appurtenant structure located below the base flood elevation must be built using flood resistant materials; iii. The appurtenant structure must be adequately anchored to prevent flotation, collapse and lateral movement; iv. Any machinery or equipment servicing the appurtenant structure must be elevated or floodproofed to or above the base flood elevation; v. The appurtenant structure must comply with floodway encroachment provisions in 15.25.050(F); and vi. The appurtenant structure must be designed to allow for the automatic entry and exit of flood waters in accordance with section 15.25.050(A)(3)(d). b. Detached garages, storage structures and other appurtenant structures not meeting the above standards must be constructed in accordance with all applicable standards in section 15.25.050(A)(3)(a) subsections (i), (ii) or (iii) as appropriate. c. Upon completion of the structure, certification that the requirements of this section have been satisfied shall be provided to the floodplain administrator for verification. 2. For V Zones (VE, V1-30 and V): Floodproofing of non-residential structures is prohibited. All structures must be elevated and constructed according to the requirements set forth in section 15.25.050(A)(3)(a). d. Flood openings. All new construction and substantial improvement with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwater. Designs for meeting this requirement must meet or exceed the following criteria: For non-engineered openings: i. Have a minimum of two openings with a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; ii. The bottom of all openings shall be no higher than one foot above grade; iii. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwater. Alternatively, a registered engineer or architect may design and certify engineered openings. Upon completion of the structure, certification that the requirements of this section have been satisfied shall be provided to the Floodplain Administrator for verification. B. Standards for storage of materials and equipment. 1. The storage or processing of materials that could be injurious to human, animal or plant life if released due to damage from flooding is prohibited in special flood hazard areas. 2. Storage of other material or equipment may be allowed if not subject to damage by floods and if firmly anchored to prevent flotation, or if readily removable from the area within the time available after flood warning. C. Standards for water supply and waste disposal systems. 1. All new or replacement water supply and sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the system and discharge from systems into flood waters. 2. On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. D. Development proposals. All new development proposals, including subdivisions and manufactured home parks, shall: 1. Be consistent with the need to minimize flood damage; 2. Have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage; and 3. Provide adequate drainage to reduce exposure to flood hazards. 4. Include base flood elevation data for all proposals greater than 50 lots or five acres, whichever is the lesser. E. Standards for recreational vehicles. All recreational vehicles placed on site shall: 1. Be on site for fewer than 180 consecutive days, 2. Be fully licensed and ready for highway use. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions; or 3. Meet the permit requirements of section 15.25.040 of this ordinance and the applicable elevation and anchoring requirements. Methods of anchoring may include, but are not to be limited to, use of over-the-top or frame ties to ground anchors. The recreational vehicle must also be elevated on a permanent foundation such that the lowest floor of the vehicle is elevated to or above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist floatation collapse and lateral movement. These requirements are in addition to applicable State and local anchoring requirements for resisting wind forces. F. Floodways. Located within the special flood hazard areas established in section 15.25.030(B) are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles and erosion potential, the following provisions apply: 1. Prohibit encroachments, including fill, new construction, substantial improvements, and other development within the adopted regulatory floodway unless it has been demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachment would not result in any increase in flood levels within the community during the occurrence of the base flood discharge; 2. If section 15.25.050(F)(1) is satisfied, all new construction and substantial improvements shall comply with all other applicable flood hazard reduction provisions of section 15.25.050. 3. Encroachments within the adopted regulatory floodway that would result in an increase in base flood elevations may be permitted, provided that the applicant first applies for and fulfills the requirements for a Conditional Letter of Map Revision (CLOMR), and receives approval from the Federal Insurance Administrator to revise the FIRM and FIS in accordance with Section 15.25.040(B)(4)(b).

(Ord. 98-11; Ord. No. 2013-010, § 1, 7-8-2013; Ord. No. 2023-009, § 5, 4-10-2023; Ord. No. 2026-001, 1, 1-26-2026)

Ask a question about Seward law

Corpus searches the Seward sections it holds and shows the ones that match, with their citations. Free, no sign-in.