Sec. 5-150.5. - Amendments.

The International Fire Code adopted in this article is amended and changed in the following respects: Any reference within this code using the term "NFPA 70" is replaced with "the currently adopted edition of NFPA 70." Any reference within this code using the term "International Existing Building Code" shall be replaced with "Chapter 4 of the International Existing Building Code." Section 106.1 is hereby amended: Construction documents and supporting data shall be submitted in two or more sets with each application for a permit and in such form and detail as required by the fire code official. The construction documents and plans shall be prepared by and shall bear the seal of a professional engineer licensed in the State of Alabama. Exception: The fire code official is authorized to waive the submission of construction documents and supporting data not required to be prepared by a registered design professional if it is found that the nature of the work applied for is such that review of construction documents is not necessary to obtain compliance with this code. Section 307.2.2 is hereby added: Each residential burn permit shall be issued for a period of time not to exceed 60 days. Section 307.2.3 is hereby added: Burn permits issued to contractors shall be issued for a period of time not to exceed 30 days and shall be site specific. Section 307.2.4 is hereby added: Under no circumstances shall heavy oils, asphaltic materials, items containing natural of synthetic rubber, plastics or refuse be burned. Section 307.4 Location, is amended to read as follows: The location for all burning shall meet the minimum requirements as specified by The Alabama Department of Environmental Management. Section 506.1.1, Locks, is hereby amended: All occupancies within the City of Auburn, having an automatic fire alarm system or fire sprinkler system, shall be equipped with an Underwriters Laboratory (U.L) type of key lock box. The key lock box shall be compatible with the master key assigned to the Fire Division. The master key is assigned only to the Auburn Fire Division. The key lock box shall be located at or near the recognized main entrance. The key lock box location shall be approved by the Inspection Services Department prior to installation. The lock box shall be located at a height of not less than six (6) feet and not more than seven (7) feet above final grade. The building owner/manager will install the lock box in the location(s) specified by the Inspection Services Department, and notify the division when it's completed. No steps, displays, signs or other fixtures, or structure protrusions shall be located under the box which would allow intruders to access the box without assistance. The box shall be connected to the N.F.P.A. 72A Fire Alarm Control Panel, when provided. Wiring shall be supervised as required in NFPA 72A. Tampering or opening of the box shall produce a Supervisory Signal on Supervisory Zone 1. The signal will then be transmitted through the NFPA 71 panel as a supervisory signal. Exception: If an NFPA 71 panel only is used, wiring shall be supervised as required in NFPA 71. Tampering or opening of the box shall produce a supervisory signal. The box shall contain the keys for the following. The keys shall be labeled so as to be easily identified in the field: 1. The main entrance door; mixed occupancies and strip shopping center keys shall be provided only for occupancies where system control valves or fire alarm system and or panel exists. Keys to locked points of egress, whether on the interior or exterior of such buildings. 2. Alarm room (if one exists). 3. Mechanical rooms 4. Sprinkler control/fire pump rooms. 5. Fire alarm control panel. 6. Electrical rooms. 7. Special keys to reset pull-stations or other fire protection devices. 8. Elevator keys including elevator room. 9. All other rooms as specified during the plans review process. Inspection Services Department shall be responsible for the administration of this standard and shall indicate specific requirements for new structures. For existing structures, Inspection Services Department shall be responsible for administration of this standard and notify the owner or operator by proper notice for compliance. Exception: Any building or site that has twenty-four-hour, seven day a week guard service shall not need to provide a key lock box. Section 510, Emergency Responder Communication Coverage, is hereby amended: 510.1 Emergency responder radio coverage in new buildings. New buildings shall have approved radio coverage within the building shall be based coverage for emergency responders within the building based on the existing coverage levels of the public safety communication systems utilized by the jurisdiction, measured at the exterior of the building. This section shall not require improvement of the existing public safety communication systems. Emergency responder radio coverage system in new buildings. An emergency responder radio coverage system shall be provided throughout buildings when any of the following apply: 1. New buildings constructed with an area more than 50,000 square feet, 2. New buildings that are more than four (4) stories in height that do not contain a basement or extend one or more levels below grade, 3. Building has a basement or levels/floors below grade, 4. Demonstrates a lack of proper ERRC coverage and the issue has been designated a distinct hazard by the building and fire code official. Exceptions: 1. Where approved by the Building Official and Fire Chief a wired communication system in accordance with Section 907.2.13.2 shall be permitted to be installed or maintained instead of an approved radio coverage system. 2. Where it is determined by the Building and Fire Chief that the radio coverage system is not needed. 3. In facilities where emergency responder radio coverage is required and such systems, components or equipment required could have a negative impact on the normal operations of that facility, the fire code official shall have the authority to accept an automatically activated emergency responder radio coverage system. 4. New buildings that can demonstrate minimum radio coverage signal strength levels of the City of Auburn emergency responder radio system throughout the interior of the building. 5. One and two-family dwellings and townhouses that are built to the International Residential Code (IRC). Table 1004.5 is amended as follows: Maximum floor area allowances per occupant, Table Section 1004.5 Assembly without fixed seats Concentrated (chairs only—not fixed) | 7 net Standing space | 7 net Unconcentrated (tables and chairs) | 15 net Section C103.2. Average spacing. The average spacing between fire hydrants shall not exceed that listed in Table C102.1 and the maximum travel distance between a hydrant and fire department connections for building sprinkler systems and standpipes shall not exceed 125 feet. Exception: The fire chief is authorized to accept existing fire hydrant spacing where they provide all or a portion of the required fire hydrant service.

(Ord. No. 1369, § 2, 10-2-90; Ord. No. 1632, § 1, 4-16-96; Ord. No. 2050, § 1, 4-2-02; Ord. No. 2164, § 12, 10-21-03; Ord. No. 2500, § 7, 8-7-07; Ord. 2534, § 1, 1-22-08; Ord. No. 2646, § 4, 1-19-10; Ord. No. 2790, § 5, 10-2-12; Ord. No. 2919, § 5, 4-21-15; Ord. No. 2990, § 3, 9-6-16; Ord. No. 3164, § 5, 6-18-19; Ord. No. 3325, § 9, 9-7-21)

Ask a question about Auburn law

Corpus searches the Auburn sections it holds and shows the ones that match, with their citations. Free, no sign-in.