§ 5-43 — Amendments
Code of Ordinances of the City of Auburn, Alabama (Codified through Ordinance No. 3567, enacted January 20, 2026. (Supp. No. 91)) · Auburn Code of Ordinances § 5-43
Corpus is an independent public-information project, not the official City of Auburn website. Stable reference: corpuslaw.us/code/9f0336db-0790-4aa5-834f-a83912b7c1ea
Sec. 5-43. - Amendments.
The International Building Code adopted in this article is amended and changed in the following respects: Any reference within this code using the term "International Energy Efficiency Code" is replaced with "applicable sections of the Alabama Commercial or Residential Energy Code". Any reference within this code using the term "NFPA 70" is replaced with "the currently adopted edition of NFPA 70". Section 903.3.1.2 NFPA 13R sprinkler systems is hereby to be amended: Automatic sprinkler systems in Group R occupancies shall be permitted to be installed throughout in accordance with NFPA 13R where the Group R occupancy meets all of the following conditions: 1. Four stories or fewer above grade plane. 2. The floor level of the highest story is 30 feet (9144 mm) or less above the lowest level of fire department vehicle access. 3. The floor level of the lowest story is 30 feet (9144 mm) or less below the lowest level of fire department vehicle access. 4. All attic spaces must be sprinkled. The number of stories of Group R occupancies constructed in accordance with Sections 510.2 and 510.4 shall be measured from grade plane. Exception: Any University recognized primary structures containing dwelling or sleeping units for any Auburn University officially recognized fraternity and/or sorority organizations, must meet Section 903.3.1.1 NFPA 13 Sprinkler System requirements. Table 1004.5 Maximum floor area allowances per occupant is hereby to be amended: Table 1004.5 Maximum floor area allowances per occupant. Table section-Assembly without fixed seats. Concentrated (chairs only-not fixed) | 7 net Standing space | 7 net Unconcentrated (tables and chairs) | 15 net Section 1015.2 Where required is hereby to be amended: Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stair, ramps and landings that are located more than 30 inches measured vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. Guards shall also be located on retaining walls over 6 feet in height. Guards shall be adequate in strength and attachment in accordance with section 1607.9. Exceptions: Guards are not required for the following locations: 1. On the loading side of loading docks or piers. 2. On the audience side of stages and raised platforms including stairs leading to the stage and raised platforms. 3. On raised stage and platform floor areas, such as runways, ramps, and side stages used for entertainment or presentations. 4. At vertical openings in the performance area of stages and platforms. 5. At elevated walking surfaces appurtenant to stages and platforms for access to and utilization of special lighting or equipment. 6. Along vehicle service pits not accessible to the public. 7. In assembly seating where guards in accordance with Section 1029.16.2 are permitted and provided. 8. On the loading side of station platforms on fixed guideway transit or passenger rail system. Section 1028.3 Exit discharge components. Exit discharge components shall be sufficiently open to the exterior so as to minimize the accumulation of smoke and toxic gases. Constructed exterior walkways shall meet a maximum 2% cross-slope. Section 1110.4.13 Swimming pools, wading pools, cold baths, hot tubs and spas to be amended: Swimming pools, wading pools, cold baths, hot tubs and spas shall be accessible and be on an accessible route(s). Exceptions: 1. Catch pools or a designated section of a pool used as a terminus for a water slide flume shall not be required to provide an accessible means of entry, provided that a portion of the catch pool edge is on an accessible route. 2. Where spas or hot tubs are provided in a cluster, at least 5 percent, but not less than one spa or hot tub in each cluster shall be accessible and be on an accessible route. 3. Swimming pools, wading pools, spas, cold baths and hot tubs that are required to be accessible by Sections 1111.2.2 and 1111.2.3 are not required to provide accessible means of entry into the water. Section 2902.6 Small occupancies shall be amended to read: Drinking fountains shall not be required for an occupant load of 50 or less.
(Ord. No. 1090, § 2, 9-7-82; Ord. No. 1122, § 1, 5-3-83; Ord. No. 1367, § 2, 10-2-90; Ord. No. 1548, § 2, 10-4-94; Ord. No. 1751, § 2, 3-17-98; Ord. No. 2164, § 2, 10-21-03; Ord. No. 2500, § 2, 8-7-07; Ord. No. 2646, § 2, 1-19-10; Ord. No. 2790, § 2, 10-2-12; Ord. No. 2919, § 2, 4-21-15; Ord. No. 2990, § 1, 9-6-16; Ord. No. 3325, § 4, 9-7-21)
Ask a question about Auburn law
Corpus searches the Auburn sections it holds and shows the ones that match, with their citations. Free, no sign-in.
