Sec. 7-42. - Specific technical standards.
In all special flood hazard areas designated as A, AE, AH (with engineered or estimated BFE), the following provisions are required: (1) Residential and nonresidential structures. Where BFE data is available, new construction, reconstruction or repairs made to a repetitive loss structure, and substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than one foot above the base flood elevation (also referred to as the design flood elevation). Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of division 4, subsection 7-42(3). (2) Nonresidential structures. New construction, reconstruction or repairs made to a repetitive loss structure, and substantial improvement of any nonresidential structure located in AE or AH zones, may be floodproofed (dry) in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to at least one foot above the base flood elevation (hereafter referred to as the design flood elevation), with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. a. A professional engineer, who is licensed to practice in the State of Alabama, or licensed architect, who is registered to practice in the State of Alabama, shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with the standards in ASCE-24 (for dry floodproofing) or other compatible standards of practice for meeting the provisions above, and shall provide such certification to the official as set forth above and in division 3, subsection 7-37(6). b. A record of such certificates, which includes the specific elevation (in relation to mean sea level) to which such structures are floodproofed, shall be maintained with the official permitting records for the structure and kept in-perpetuity. c. Any nonresidential functionally dependent structure (as defined in division 6) that cannot meet the standards stated in subsection 7-42(2)a. shall require a variance to be issued in accordance with division 5, subsections 7-52(3) and 7-53(1). d. Any nonresidential structure, or part thereof, made watertight below the DFE shall be floodproofed in accordance with the applicable standards in ASCE 24. All plans and specifications for such floodproofing shall be accompanied by a statement certified by a professional engineer, who is licensed to practice in the State of Alabama, or licensed architect, who is registered to practice in the State of Alabama, which states that the proposed design and methods of construction are in conformance with the above-referenced standards. There should be a statement submitted with the permit application and a statement submitted with the as-built floodproofing certificate prior to the issuance of the certificate of occupancy. (3) Enclosures for elevated buildings. All new construction, reconstruction or repairs made to a repetitive loss structure, and substantial improvements of existing structures (residential and nonresidential) that include ANY fully enclosed area below the BFE, located below the lowest floor formed by the foundation and other exterior walls shall be designed so as to be an unfinished or flood resistant enclosure. The enclosure shall be designed to equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of flood waters. a. Designs for complying with this requirement must either be certified by a professional engineer, who is licensed to practice in the State of Alabama, or a licensed architect, registered to practice in the State of Alabama, or meet the following minimum criteria: 1. Provide a minimum of two (2) openings for each enclosed area having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding (if a structure has more than one enclosed area below the BFE, each shall have openings on exterior walls); 2. Openings shall be in at least two (2) walls of each enclosed area (includes areas separated by interior walls); 3. The bottom of all openings shall be no higher than one foot above grade; 4. Openings may be equipped with screens, louvers, valves and other coverings or devices provided that they permit the automatic entry and exit of floodwaters in both directions without impeding or blocking flow and shall be accounted for in determination of the net open area; and 5. Openings meeting the requirements of subsections 7-42(3)a.1.—4. that are installed in doors are permitted. b. So as not to violate the "lowest floor" criteria of this article, the unfinished or flood resistant enclosure shall only be used for parking of vehicles, limited storage, or access to the elevated area. c. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. d. All interior walls, ceilings and floors below the BFE shall be unfinished and/or constructed of flood damage-resistant materials. This practice is also referred to as "wet floodproofing." The definitions for "flood damage-resistant materials" and "wet floodproofing" are included in division 6. e. Mechanical, electrical, or plumbing devices shall be installed not less than one foot above the BFE. The interior portion of such enclosed area(s) shall be void of utilities except for essential lighting and power, as required, that are watertight or have otherwise been floodproofed. (4) Standards for manufactured homes and recreational vehicles where base flood elevation data is available. a. Require that all manufactured homes placed or substantially improved: 1. Outside of a manufactured home park or subdivision, 2. In a new or substantially improved manufactured home park or subdivision, 3. In an expansion to an existing manufactured home park or subdivision, or 4. In an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as the result of a flood, be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated one foot or more above the BFE and be securely anchored to an adequately anchored foundation system to resist floatation, collapse, and lateral movement. b. Require that all manufactured homes to be placed or substantially improved on sites in an existing manufactured home park or subdivision that are not subject to the provisions of subsection 7-42(4)a. be elevated so that either: 1. The lowest floor of the manufactured home is one foot or more above the BFE; or 2. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than thirty-six (36) inches in height above the highest adjacent grade and be securely anchored to an adequately anchored foundation system to resist floatation, collapse, and lateral movement. 3. Concrete block piers (and other foundation systems) are to be designed in accordance with the Code of Federal Regulations title 24, part 3285 and with the specifications in FEMA P-85: Protecting Manufactured Homes from Floods and Other Hazards—A Multi-Hazard Foundation and Installation Guide. The § 3285.306 design procedures for concrete block piers and FEMA P-85 (Table SP-1.1), specify that the maximum allowable pier height (measured from top of grade) for concrete piers to be five (5) feet. 4. The chassis and its supporting equipment are to be above the pier or other foundation. The areas below the chassis must be constructed with flood-resistant materials. All utilities and mechanical equipment must be elevated to a minimum of three (3) feet above the highest adjacent grade. Any utility and mechanical components that must be below the BFE must be made watertight to that same elevation to meet the standards in division 4, subsection 7-41(5). c. Require that all recreational vehicles placed on sites must either: 1. Be on the site for fewer than one hundred eighty (180) consecutive days, 2. Be fully licensed and ready for highway use on its wheels or jacking system, 3. Be attached to the site only by quick disconnect type utilities and security devices, and have no permanently attached structures or additions; or 4. Must meet all the requirements for "new construction," including the anchoring and elevation requirements of division 4, section 7-42, subsections (4)a. and b. (5) Standards for manufactured homes where no base flood elevation exists. a. Require that all manufactured homes to be placed within a zone A area on the FIRM shall be installed using methods and practices which minimize flood damage. b. Manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not to be limited to, use of over-the-top or frame ties to ground anchors. c. The manufactured home chassis must be supported by reinforced piers or other foundation elements of at least equivalent strength such that the bottom of the chassis and its supporting equipment be no less than thirty-six (36) inches and up to a maximum sixty (60) inches (five (5) feet) above the highest adjacent grade and be securely anchored to an adequately anchored foundation system. d. The areas below the chassis must be constructed with flood-resistant materials. All utilities and mechanical equipment must be elevated to a minimum of three (3) feet above the highest adjacent grade. Any utility and mechanical components that must be below the BFE must be made watertight to that same elevation to meet the standards in division 4, subsection 7-41(5). (6) Require, until a regulatory floodway is designated, that no new construction, substantial improvements, or other development (including fill) shall be permitted within zones A and AE on the City of Auburn's FIRM, unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one foot at any point within the community. (7) Accessory and agricultural structures. When an accessory structure meets the requirements outlined below, these structures may be wet-floodproofed and do not have to be elevated to one foot above the BFE as required in division 4, subsection 7-42(1). A permit shall be required prior to construction or installation of any accessory structures and any agricultural structures built below the DFE and the following provisions apply: a. Must be adequately anchored to prevent flotation, collapse, or lateral movement; b. Must be designed with an unfinished interior and constructed with flood damage-resistant materials below the DFE as described in division 4, subsection 7-42(3); c. Must have adequate flood openings as described in division 4, subsection 7-42(3); d. Must be constructed and placed on the building site so as to offer the minimum resistance to the flow of floodwaters; e. Must comply with the requirements for development in floodways in accordance with division 4, section 7-43; f. Must elevate any mechanical and other utility equipment in or servicing the structure to or above the DFE or must be floodproofed in accordance with division 4, section 7-41; g. Prohibit storage of any hazardous or toxic materials below the DFE. h. Permits for small accessory structures may be issued to provide wet floodproofing measures in accordance with the standards described in subsections (i) through (iv) below without requiring a variance. Before issuing permits for small accessory structures, the floodplain administrator must verify: 1. Use is limited to parking of vehicles or storage; 2. Size is less than or equal to a one-story, two-car garage for all A zones; 3. Structures are a minimal investment and have a low damage potential with respect to the structure and contents; 4. Structures will not be used for human habitation; 5. Structures comply with the wet floodproofing requirements in division 4, subsection 7-42(3). i. Permits for accessory structures larger than the size allowed for in subsection (7)h. above, shall require a variance to be granted on a case-by-case basis in accordance with division 5, subsection 7-53(3). Variances shall not be granted for entire subdivisions for accessory structures. j. Permits for new construction of all agricultural structures shall require a variance to be granted on a case-by-case basis in accordance with division 5, subsection 7-53(4). (8) Underground and aboveground storage (liquid and gas) tanks. Tanks and tank inlets, fill openings, outlets, and vents that are located below the DFE shall be designed, constructed, installed, and anchored to resist all flood-related loads (flotation, collapse, or lateral movement resulting from hydrostatic and hydrodynamic forces) and any other loads, including the effects of buoyancy, during flooding up to and including the 100-year flood and without release of contents into floodwaters or infiltration of floodwaters into the tanks. a. A permit that includes floodplain development shall be required prior to construction or installation of any underground and aboveground tanks (including their foundation and support systems) located within a special flood hazard area. b. Loads on underground tanks and aboveground tanks exposed to flooding shall be determined assuming at least 1.3 times the potential buoyant and other flood forces acting on the empty tank. c. Tanks and associated piping shall be installed to resist local scour and erosion during the 100-year flood. d. Aboveground tanks located in zone A/AE flood hazard areas shall be either: 1. Elevated to or above the DFE on platforms or structural fill; 2. Elevated to or above the DFE where attached to structures and the foundation system supporting the structures shall be designed to accommodate any increased loads resulting from the attached tanks; 3. Permitted below the DFE where the tank and its foundation are designed to resist all flood-related loads including floating debris; or 4. Permitted below the DFE where the tank and its foundation are designed to resist flood loads and are located inside a barrier designed to protect the tank from floating debris. e. Aboveground tanks located in areas designated as zone V/VE, coastal A-zones, and other high risk flood hazard areas (see ASCE 24-14) shall be elevated to or above the DFE on platforms that conform to the foundation requirements of ASCE 24-14, section 4.5. Aboveground tanks shall not be permitted to be located under elevated structures or attached to structures at elevations below one foot above the DFE in these areas. f. Underground tanks located in areas designated as zone V/VE, coastal A-zones, and other high risk flood hazard areas (see ASCE 24-14) shall have the determination of flood-related loads take into consideration the eroded ground elevation. g. Tank inlets, fill openings, outlets, and vents shall be: 1. At or above the DFE or fitted with covers designed to prevent the inflow of floodwater or outflow of the contents of the tanks during conditions of the 100-year flood. 2. Anchored to prevent lateral movement resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy, during conditions of the 100-year flood. (9) Structures and sites for the storage or production of hazardous substances. Require that all outdoor storage sites, new construction, reconstruction or repairs made to a repetitive loss structure, and substantial improvements to be used for the production or storage of hazard substances (as defined in division 6) which are located in the special flood hazard area shall be built in accordance with all applicable standards in this article in addition to the following requirements: a. No structures containing hazardous substances shall be permitted for construction in a floodway; b. Residential structures shall have the area in which the hazard substances are to be stored elevated or dry floodproofed a minimum of two (2) feet above the BFE; c. Nonresidential structures shall be permitted to be built below the BFE in accordance with division 4, subsection 7-42(2) such that the area where the hazard substance production or storage is located will be: 1. elevated or designed and constructed to remain completely dry to at least two (2) feet above the BFE, and 2. designed to prevent pollution from the storage containers, structure, or activity during the course of the base flood. d. Any solid, liquid, or gas storage containers of hazardous substances and any associated mechanical, electrical, and conveyance equipment shall be watertight and shall be properly anchored and protected from the hydrostatic and hydrodynamic forces of flood waters and debris carried by the base flood. It is prohibited for any outdoor storage sites, new construction and substantial improvements used for the production or storage of hazardous substances (as defined in division 6) to be located within the SFHA. (10) Construction of fences. New and replacement fences may be allowed in flood hazard areas if they do not act as a flow boundary and redirect the direction of flow, collect flood debris and cause blockages, cause localized increases in flood levels, or if damaged, become debris that may cause damage to other structures. (11) Structures elevated on fill. Fill for structures shall be designed to be stable under conditions of flooding, including rapid rise and rapid drawdown of floodwaters, prolonged inundation, and flood-related erosion and scour. The standards from ASCE 24 should be followed for any fill placed in flood hazard areas. All new construction for residential or nonresidential structures may be constructed on permanent structural fill in accordance with the following: a. The lowest floor (including basement) of the structure or addition along with any appurtenant utilities shall be no lower than one foot above the BFE. b. The nearest wall foundation of the structure shall have a minimum setback distance of twenty-five (25) feet from the edge of the floodplain boundary. c. Fill used for structural support or protection shall consist of granular and earthen material that is free of vegetation and foreign or organic materials and suitable for its intended use. d. The fill shall be placed in layers no greater than one foot deep before compacting and should extend at least ten (10) feet beyond the foundation of the structure before sloping below the BFE, said slope being no greater than a 1:1.5 (vertical/horizontal) ratio unless a stability analysis is provided by a registered professional engineer. However, the ten-foot minimum may be waived if a structural engineer certifies an alternative method to protect the structure from damage due to erosion, scour, and other hydrodynamic forces. e. All new structures built on fill must be constructed on properly designed and compacted fill (ASTM D-698 or equivalent) that extends beyond the building walls before dropping below the BFE. f. The top of the fill shall be no lower than one foot above the BFE. g. The fill shall not adversely affect the flow or surface drainage from or onto any neighboring properties. h. Structural fill, including side slopes, shall be protected from scour and erosion under flood conditions up to and including the base flood discharge. When expected velocities during the occurrence of the base flood are greater than five (5) feet per second, armoring with stone or rock protection shall be provided. When expected velocities during the base flood are five (5) feet per second or less, protection shall be provided by covering them with vegetative ground cover. i. The design of the fill or the fill standard must be approved by a licensed professional engineer. j. The applicant shall submit a letter of map revision based on fill (LOMR-F) utilizing FEMA's MT-1 application forms to FEMA requesting a revision to the FIRM for the placement of fill. k. This standard is not applicable for placement of fill in a floodway; fill in a floodway is prohibited. (12) Compensatory storage for filling. Fill within the SFHA shall result in no net loss of natural floodplain storage. Compensatory storage cannot be used within the limits of floodways as depicted on FIRMs. Any development utilizing this approach shall prepare design documentation in accordance with the following: a. Loss of floodwater storage volume due to filling in the special flood hazard area shall be offset by providing an equal volume of flood storage by excavation or other compensatory measures at or adjacent to the development site. b. Provide adequate documentation demonstrating the compensatory storage volume including but not limited to engineering analysis/calculations, site plan and profile drawings of the area to be filled and excavated, and environmental impact assessments for areas filled and excavated. c. Any excavation or other measures taken for compensatory storage shall be properly designed to provide protection against erosion or overgrowth of vegetation in order to preserve the storage volume. d. The compensatory storage approach cannot be utilized in erosion-prone areas. The site being considered must be determined not to be erosion-prone by analyzing available studies, historical data, watershed trends, average annual erosion rates, flood velocities and duration of flow, geotechnical data, and existing protective works. Results of these analyses shall be documented in an engineering report, which defines the data and methodology used to determine whether or not an area is erosion-prone. e. An operations and maintenance plan for maintaining the integrity and intended volume of the compensatory storage area in perpetuity shall be included with the permit. The plan must be approved by the floodplain administrator and shall be legally binding upon the owner whose property that the compensatory storage area is located. (13) Incompatible uses prohibited in SFHAS. a. Lands lying within the 100-year floodplain shall not be used for: 1. dumping of any material or substance including solid waste disposal sites (including manure), 2. on-site soil absorption sanitary sewage system site, 3. petroleum or chemical holding tanks, 4. construction of any wells used to obtain water for ultimate human consumption; or 5. restricted confinement or permanent sheltering of animals. b. Lands lying within the 100-year floodplain shall not be used for the storage of materials that are buoyant, flammable, explosive, or injurious to human, animal, plant, fish, or other aquatic life.
(Ord. No. 3523, § 1, 12-3-24)
Ask a question about Auburn law
Corpus searches the Auburn sections it holds and shows the ones that match, with their citations. Free, no sign-in.