§ 7-44 — Building standards for streams without established base flood elevations (approximate A-zones)
Code of Ordinances of the City of Auburn, Alabama (Codified through Ordinance No. 3567, enacted January 20, 2026. (Supp. No. 91)) · Auburn Code of Ordinances § 7-44
Corpus is an independent public-information project, not the official City of Auburn website. Stable reference: corpuslaw.us/code/c4162ab9-ca4d-432c-ad6f-8a268a4eda86
Sec. 7-44. - Building standards for streams without established base flood elevations (approximate A-zones).
Located within the SFHAs established in division 2, section 7-21, where streams exist but no base flood data have been provided (approximate A-zones), the following provisions apply: (1) BFE data shall be provided for new subdivision proposals and other proposed development (including manufactured home parks and subdivisions) greater than fifty (50) lots or five (5) acres, whichever is the lesser. (2) When BFE data or floodway data have not been provided in accordance with division 2, section 7-21 then the floodplain administrator shall obtain, review, and reasonably utilize any scientific or historic BFE and floodway data available from a federal, state, or other source, in order to administer the provisions of division 4. Only if data are not available from these sources, then division 4, section 7-44, subsections (4) and (5) shall apply. (3) All development in zone A must meet the requirements of division 4, section 7-41 and subsections 7-42(1)—(3), (5)—(10). (4) In SFHAs without BFE data, new construction and substantial improvements of existing structures shall have the lowest floor (for the lowest enclosed area; including basement) elevated no less than three (3) feet above the highest adjacent grade. As the requirements set forth in division 4, subsection 7-42(1) and (2) stipulate the lowest floor to be elevated no less than one foot about the BFE, then the structure for this condition shall be elevated no less than four (4) feet about the highest adjacent grade. (5) In the absence of a BFE, a manufactured home must also meet the elevation requirements of division 4, subsections 7-42(4)b.2.—4. in that the structure cannot be elevated above a maximum of sixty (60) inches (five (5) feet) and all utilities and mechanical equipment must be elevated a minimum of three (3) feet above the highest adjacent grade. (6) Enclosures for elevated buildings in zone A areas shall comply with the standards of division 4, subsection 7-42(3)a. The floodplain administrator shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file.
(Ord. No. 3523, § 1, 12-3-24)
Ask a question about Auburn law
Corpus searches the Auburn sections it holds and shows the ones that match, with their citations. Free, no sign-in.