Sec. 4-7-18. - Design and performance standards.

(a) All applications for a permit, except those related to the construction of individual single-family residences, must contain, or be accompanied by a soil erosion and sediment control plan ("control plan"). The control plan shall be prepared by a qualified credentialed professional and shall include the following: (1) The control plan shall be accompanied by a map or plot of the property upon which land-disturbing activities are to be conducted, prepared by a registered land surveyor, showing the present contour lines of such property, and the present contour lines of at least the nearest 25 feet of the properties immediately adjacent to such property and the existing grades and elevations of all streets which abut such property. Such map or plot shall show all existing drainage facilities and all natural drainage on such property and on such adjacent property. (2) All proposed contours, the proposed temporary and permanent disposition of surface water and the proposed drainage structures; provided, however, the control plans for utility projects, except sewer projects, shall not be required to show the proposed contours. (3) The proposed contours in the map or plot shall be depicted in contour intervals of two or fewer feet; provided, however, the control plans for utility projects, except sewer projects, shall not be required to show the proposed contours. All maps, plots and plans submitted shall be on a sheet of paper at least 24 inches by 36 inches and drawn to a scale of not less than one inch equals 100 feet. Contour intervals of more than two feet and maps, plots or plans which are smaller than the required size may be approved by the city engineer, upon written request and for good cause shown. (b) The control plan shall contain a description of the existing site conditions, a description of adjacent topographical features, the information necessary to determine the erosion qualities of the soil on the site, potential problem areas of soil erosion and sedimentation, soil stabilization specifications, provision for saving topsoil for later revegetation, provision for saving trees and other vegetation and any retention of a buffer, intended means of revegetation and any provision of a buffer, proposed protective measures for controlling erosion and sediment, both temporary and permanent, storm water management considerations, a projected time schedule for the commencement and completion of the land-disturbing activity, specifications for BMP plan maintenance during the project and after the completion of the project, clearing and grading limits, and all other information needed to depict accurately the solutions to potential soil erosion and sedimentation problems

(Ord. No. 99-131, § 1(207), 7-15-1999)

Ask a question about Birmingham law

Corpus searches the Birmingham sections it holds and shows the ones that match, with their citations. Free, no sign-in.