Sec. 96-11. - Type and height of towers.
(a) All new towers shall be of the monopole type. No new towers of a lattice or guyed type shall be permitted, unless relief is otherwise expressly requested and granted based on the provision of clear and convincing technical evidence. (b) The applicant for a new tower shall submit clear and convincing technical evidence by a carrier or wireless service provider justifying the total height of the proposed facility and the need for such to the exclusion of all reasonable alternatives. Evidence in the form of propagation studies must include all modeling data and assumptions used to produce the studies at the requested height and at a height ten feet lower to show that any lower height would have the effect of prohibiting the provision of service. (c) The city reserves the right to require a drive test to be conducted under the supervision of the city or its designee as evidence of the technical need for what is requested. (d) The maximum permitted total height of a new tower or support structure in nonresidential zoned areas shall be 100 feet above pre-construction ground level, unless it can be shown by clear and convincing technical evidence that such height would prohibit or have the effect of prohibiting the provision of service in the intended service area within the city. The maximum permitted total height of a new tower or support structure in districts zoned R-1, R-2, R-3, R-4, R-A, MH-1, MH-2, O-2, O-3 shall be 60 feet above pre-construction ground level, unless it can be shown by clear and convincing technical evidence that such height would prohibit or have the effect of prohibiting the provision of service in the intended service area within the city. The maximum permitted height is expressly not an as-of-right height, but rather the maximum permitted height absent clear and convincing technical evidence of the technological need for a greater height. (e) As the city has made the policy decision that more facilities of a shorter height is in the public interest, as opposed to fewer taller facilities, spacing or the distance between facilities shall be such that the service may be provided without exceeding the maximum permitted height. (f) With respect to the overall designed strength of a tower, but not with respect to height, towers shall be structurally designed to accommodate a minimum of four carriers using substantially similar equipment to that used by the first carrier attaching to a tower and that can be increased in height if needed for technical reasons.
(Ord. No. 2017-1, § 2, 1-3-17)
Ask a question about Dothan law
Corpus searches the Dothan sections it holds and shows the ones that match, with their citations. Free, no sign-in.