§ 6-2.8 — Amendments to the energy conservation code

Code of Ordinances of the City of Hoover, Alabama (Supplement 23, published 2025-05-19 (Municode online 2026-03-30).) · Hoover Municipal Code § 6-2.8

Corpus is an independent public-information project, not the official City of Hoover website. Stable reference: corpuslaw.us/code/218a9782-5f4a-437e-92b7-cdaa6b4d3a7e

Sec. 6-2.8. - Amendments to the energy conservation code.

The following sections are hereby amended as follows. Where a conflict exists between the provisions of the International Energy Conservation Code and the following amendments, the amendments shall prevail. Section C101.1 Delete section in its entirety and replace with the following: C101.1 Title. These regulations shall be known as the Energy Conservation Code of the City of Hoover, hereinafter referred to as "this code. Section C109.4 Delete subsection in its entirety and replace with the following: Section C109.4 Failure to comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be guilty of a violation against the City of Hoover punishable as provided in Section 1-5 of the Municipal Code of the City of Hoover. Each day that a violation continues shall be deemed a separate offense. Section C110 Delete Section C110 in its entirety (including sections C110.1 through C110.4 thereunder) and replace with the following: SECTION C110 APPEALS C110.1 General. Appeals of orders, decisions, and determinations made by the building official related to the application and interpretation of this code shall be heard by the Hoover Code Appeals Board pursuant to Chapter 6, Article I, Section 6-7 of the Municipal Code of the City of Hoover and according to the appeal procedures set forth therein. Appeals shall be filed with the Hoover Code Appeals Board within twenty (20) days following the date of the decision of the code official for which appeal is sought. C110.2 Limitations on authority. An application for appeal shall be based on a claim that the true intent of this code or the rules legally adopted thereunder have been incorrectly interpreted, the provisions of this code do not fully apply or an equally good or better form of construction is proposed. C110.3 Administration. The code official shall take immediate action in accordance with the decision of the Hoover Code Appeals Board. R402.4.1.2 Testing. The building or dwelling unit shall be tested for air leakage. The maximum air leakage rate for any building or dwelling unit under any compliance path shall not exceed 5.0 air changes per hour or 0.28 cubic feet per minute (CFM) per square foot [0.0079 m3/ (s x m2)] of dwelling unit enclosure area. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380, ASTM E779 or ASTM E1827 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope have been sealed. Table R405.4.2(1) "Specifications for the Standard Reference and Proposed Designs" - Delete table row relating to "Air exchange rate" as written and replace it with the following: BUILDING COMPONENT | STANDARD REFERENCE DESIGN | PROPOSED DESIGN Air Exchange Rate | The air leakage rate shall be at a pressure of 0.2-inch w.g. (50 Pa.) | The measured air exchange rate a The mechanical ventilation rate b shall be in addition to the air leakage rate and shall be as proposed. The mechanical ventilation rate shall be in addition to the air leakage rate and shall be the same as in the proposed design, but not greater than 0.01 x CFA + 7.5 x (Nbr + 1) where: CFA = conditioned floor area, ft 2 Nbr = number of bedrooms The mechanical ventilation system type shall be the same as in the proposed design. Energy recovery shall not be assumed for mechanical ventilation.

(Ord. No. 22-2556, § 8.B, 3-21-22; Ord. No. 23-2620, §§ 1, 2, 9-18-23)

Ask a question about Hoover law

Corpus searches the Hoover sections it holds and shows the ones that match, with their citations. Free, no sign-in.