For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6 — Frontage standards

Code of the City of Mobile, Alabama (Supp. No. 67: codified through Ordinance No. 36-017-2026, adopted March 1, 2026) · Mobile City Code, App. A, § 6

Corpus is an independent public-information project, not the official City of Mobile website. Stable reference: corpuslaw.us/code/837150e3-12de-4415-b62c-6e749b68e098

Section 6. - Frontage standards.

A. Frontage types established. The frontage in table 6.1: Frontage Types, is established: Table 6.1: Frontage Types Frontage Type | Section 6.___ Lawn frontage type | F Terrace frontage type | G Stoop frontage type | H Common entry frontage type | I Pedestrian forecourt frontage type | J Vehicular forecourt frontage type | K Gallery frontage type | L Shopfront frontage type | M B. Allowed and required frontage types. 1. When new development or substantial improvements to existing buildings are proposed, or when the primary frontage of the property is designated to another abutting street, a property owner shall designate the frontage type that applies to the building in accordance with the requirements in table 6.2: Building Frontage Types Allowed, based on the applicable sub-district. 2. No frontage designation is required for work involving new additions to existing buildings that do not constitute substantial improvements. 3. If buildings have multiple frontage or multiple buildings are located on one property, the same frontage type shall be selected for all frontages. 4. A shopfront frontage is required for all ground-floor commercial uses that front the A-Street portions of Dauphin, Conti, and St. Joseph's Streets. Table 6.2: Building Frontage Types Allowed Frontage Types | T-6 | T-5 (both) | T-4 | T-3 | Municipal | Open | SD-WH Lawn | • | • | • | • | • Terrace | • | • | • | • | • | • Stoop | • | • | • | • | • | • Common Entry | • | • | • | • | • Pedestrian forecourt | • | • | • | • | • Vehicular forecourt | • | • | • | • Gallery | • | • | • | • Shopfront [1] | • | • | • | • | • | • • = Permitted C. General frontage standards. 1. At least 80 percent of the frontage in the T-5.1 sub-district and one hundred (100) percent of the T-5.2 and T-6 sub-districts shall be built out to the zone between the minimum setback and maximum setback for both the primary and secondary frontages, or shall contain a streetscreen that: (a) Is between four (4) and eight (8) feet in height; (b) Contains openings for vehicular access that are no more than thirty (30) feet in width; (c) Is made of brick, stone, stucco over masonry, iron, steel, or aluminum that appears to be iron; and (d) If not opaque, includes landscape plantings, such as a hedge, evergreen fines, or other evergreen planting materials, that increase the opacity of the streetscreen. 2. Except in the Municipal and Open sub-districts, each frontage shall contain no more than one (1) walkway a maximum of five (5) feet in width that provides access to primary and secondary entrances. In the Municipal and Open sub-districts, there are no restrictions on walkway width or the number of walkways. 3. The first floor may be elevated above the maximum established in this section where the one hundred-year flood plain (AE) and five hundred-year flood plain (X-shaded) standards require additional elevation. D. Encroachments. Encroachments into the right-of-way are provided in accordance with the following: 1. A balcony may project three (3) feet from the façade and may extend into the right-of-way, subject to a permit and right-of-way use agreement from the city engineer. 2. Other encroachments or permanent structures greater than three (3) feet in height constructed in the right of way may be permitted, subject to a permit and right-of-way use agreement from the city engineer who may require that the property owner procure and maintain general liability insurance that names the city as an additional insured. 3. Awnings, marquees, or canopies may extend into the right-of-way, except that a canopy supported by a pole or column in the right of way shall require a permit and a right-of-way use agreement from the city engineer and shall not extend within two (2) feet of a curb. E. Additions to existing buildings. Additions to existing buildings shall comply with the following frontage standards: 1. General standards. (a) Existing buildings that are nonconforming with respect to the frontage standards of the DDD code are not required to meet frontage type requirements unless the frontage is reoriented so that the principal entrance to the façade faces a different primary frontage street. (b) Additions to existing buildings may match the foundations, porch depth, and finished floor elevations of the existing building. (c) Porches, stairs, stoops, and ramps that are added to existing buildings may encroach into the front setback in accordance with the following: (1) All such features may encroach up to fifty (50) percent of the front setback depth in the T-3 sub-district, and one hundred (100) percent in all other sub-districts. (2) Porches shall be at least eight (8) feet deep in the T-3 sub-district, and five (5) feet deep in the T-4 sub-district. (d) Alterations to existing facades facing a frontage shall not reduce the percentage of the façade that is transparent below the percentage transparency of the existing façade or the percentage transparency required for the applicable frontage type, whichever is less. 2. Specific standards. (a) Additions to existing buildings in T-3 sub-district. Additions to existing buildings in the T-3 sub-district shall comply with the standards in table 6.3: Additions to Existing Buildings in T-3 Sub-District. Table 6.3: Additions to Existing Buildings in T-3 Sub-District Standard | Value Finished floor elevation | Match existing structure, or between 16 and 48 inches above average grade along the front property line Front yard terrace | Raised up to 36 inches above sidewalk grade, to form a terrace Fence or wall | Permitted along front property line and side lot lines to facade of building, with maximum height of four feet Shopfront | Prohibited Gallery | Prohibited (b) Additions to existing buildings in T-4 sub-district. Additions to existing buildings in the T-4 sub-district shall comply with the standards in table 6.4: Additions to Existing Buildings in T-4 Sub-District. Table 6.4: Additions to Existing Buildings in T-4 Sub-District Standard | Value Finished floor elevation | Match existing structure, or between 16 and 48 inches above average grade along the front property line. If shopfront is incorporated, may be at sidewalk level Front yard terrace | Raised up to 36 inches above sidewalk grade, to form a terrace Fence or wall | Permitted along front property line and side lot lines to facade of building, with maximum height of four feet and with or without masonry piers Paving | Frontage may be paved up to 100 percent of area, using unit masonry or concrete Shopfront | Permitted Gallery | Prohibited (c) Additions to existing buildings in T-5 sub-district. Additions to existing buildings in the T-5 sub-district shall comply with the standards in table 6.5: Additions to Existing Buildings in T-5 Sub-District. Table 6.5: Additions to Existing Buildings in T-5 Sub-District Standard | Value Finished floor elevation | Match existing structure, or up to 30 inches above average grade along the front property line. Front yard terrace | Raised up to 20 inches above sidewalk grade, to form a terrace Fence or wall | Permitted along front property line and side lot lines to façade of building, with maximum height of four feet and with or without masonry piers. Wood fences prohibited in T-5.2 sub-district Walkways | One per building entrance with a maximum width of five feet Paving | Frontage may be paved up to 100 percent of area, using unit masonry or concrete Courtyard | May be incorporated into frontage with a portion of the façade recessed beyond the maximum front setback, and a maximum area of 600 square feet. Shopfront | Permitted Gallery | Permitted (d) Additions to existing buildings in T-6 sub-district. Additions to existing buildings in the T-6 sub-district shall comply with the standards in table 6.6: Additions to Existing Buildings in T-6 Sub-District. Table 6.6: Additions to Existing Buildings in T-6 Sub-District Standard | Value Finished floor elevation | Match existing structure, or up to 30 inches above average grade along the front property line. Front yard terrace | Raised up to 20 inches above sidewalk grade, to form a terrace Fence or wall | Permitted along front property line and side lot lines to façade of building, with maximum height of four feet and with or without masonry piers. Wood fences prohibited Paving | Frontage may be paved up to 100 percent of area, using unit masonry or concrete Courtyard | May be incorporated into frontage with a portion of the façade recessed beyond the maximum front setback, and a maximum area of 1,600 square feet. Shopfront | Permitted Gallery | Permitted (e) Additions to existing buildings in Municipal and Open sub-districts. Additions to existing buildings in the Municipal and Open sub-districts shall comply with the standards in table 6.7: Additions to Existing Buildings in Municipal and Open Sub-Districts. Table 6.7: Additions to Existing Buildings in Municipal and Open Sub-Districts Standard | Value Finished floor elevation | Match existing structure, up to 30 inches above average grade along the front property line, or as required to meet minimum flood elevation requirements. Front yard terrace | Raised up to 20 inches above sidewalk grade, to form a terrace Fence or wall | Permitted along front property line and side lot lines to facade of building, with maximum height of ten feet and with or without masonry piers. Paving | Frontage may be paved up to 100 percent of area, using unit masonry, concrete, asphalt, or aggregate Courtyard | May be incorporated into frontage with a portion of the façade recessed beyond the maximum front setback, and a maximum area of 1,600 square feet. Shopfront | Permitted Gallery | Prohibited (f) Additions to existing buildings in SD-WH sub-district. Additions to existing buildings in the SD-WH sub-district shall comply with the standards in table 6.8: Additions to Existing Buildings in SD-WH Sub-District. Table 6.8: Additions to Existing Buildings in SD-WH Sub-District Standard | Value Finished floor elevation | Match existing structure, or up to 30 inches above average grade along the front property line. Front yard terrace | Raised up to 20 inches above sidewalk grade, to form a terrace Fence or wall | Iron fence permitted along front property line and side lot lines to façade of building, with maximum height of six feet and with or without masonry piers. Paving | Frontage may be paved up to 100 percent of area, using unit masonry or concrete Courtyard | May be incorporated into frontage with a portion of the facade recessed beyond the maximum front setback, and a maximum area of 1,600 square feet. Shopfront | Permitted Gallery | Prohibited F. Lawn frontage type. 1. General characteristics. In the lawn frontage type, the façade is set back from the front property line with the first story elevated from the sidewalk for privacy and principal entry accessed by a porch or stoop. 2. Standards. Development using a lawn frontage type shall comply with the standards in table 6.9: Lawn Frontage Type Standards. Table 6.9: Lawn Frontage Type Standards Site features | Applicable Sub-districts | [image omitted; see the official code] T-6 | T-5 (both) | T-4 | T-3 | Municipal | Open | SD-WH Finished floor elevation, first floor (min/max) | [image omitted; see the official code] | • | • | • | 16 in/48 in (measured from average grade at property line) • | • | As required to comply with flood elevation requirements Encroachment depth (max) Porches, stairs, ramps | [image omitted; see the official code] | • | 50 percent of front setback depth, min porch depth of 8 ft • | 100 percent of front setback depth, min porch depth of 4 ft Bay windows, roof overhangs, cornices, windows and door surrounds, other façade decorations | [image omitted; see the official code] | • | • | • | • | • | 2 ft Stoops | [image omitted; see the official code] | • | • | • | • | • | 4 ft (may be covered by a roof structure supported by columns or wall brackets) Fences Front property line and side lot lines to façade of building, max height | • | • | • | • | • | 4 ft Along side and rear property lines behind front façade, max height | • | • | 8 ft • | • | • | 10 ft Permitted materials | • | • | • | Wood picket, wood slat, wood lattice, iron or steel, brick, stone, stucco over masonry, aluminum that appears to be iron • | • | All materials permitted Building foundations | • | • | • | Brick stone, or stucco pier and inset fill-panel construction, or chain wall construction with panels inset to resemble pier and infill panel construction. Infill between piers shall be brick, stone, stucco, wood lattice, or vertical wood picket and shall be recessed so that piers protrude from the infill • | • | No limitations G. Terrace frontage type. 1. General characteristics. In the terrace frontage type, the façade is set back from the front property line by an elevated patio. A terrace frontage may include all elements of a shopfront frontage (see subsection L below) at the level of the terrace. 2. Standards. Development using a terrace frontage type shall comply with the standards in table 6.10: Terrace Frontage Type Standards. Table 6.10: Terrace Frontage Type Standards Site features | Applicable Sub-districts | [image omitted; see the official code] T-6 | T-5 (both) | T-4 | T-3 | Municipal | Open | SD-WH Finished floor elevation, first floor (min/max) | [image omitted; see the official code] | • | • | • | • | 20 in/36 in (measured from average grade at property line) • | • | As required to comply with flood elevation requirements Terrace standards Elevation (min/max) | [image omitted; see the official code] | • | • | • | • | • | • | 20 in/36 in Required encroachment | • | • | • | • | • | • | 100 percent of width of facade, at primary frontage, except where driveways are permitted Depth (max) | [image omitted; see the official code] | • | • | • | • | • | • | 8 ft (may extend to front property line) Surfacing | • | • | • | • | Paved or unpaved, with unit masonry or concrete • | • | Paved or landscaped Fences and Walls Fences allowed | • | • | • | • | • | • | Only where necessary as part of terrace structure or to provide a safety railing Fence and wall materials | • | • | • | • | Fences: Iron, steel, or aluminum that appears to be iron Walls: Brick, stone, or stucco • | • | All materials permitted Awnings Material and type | • | • | • | • | • | • | Fabric, fixed or movable Primary frontage, span | Ground floor | • | • | • | • | • | • | Min 80 percent of frontage without gaps except between separate businesses. If awning covers only the principal entrance, shall be the width of the principal entrance Other floors | • | • | • | • | • | • | Shall cover only a window/door and match width of window/door Primary frontage, projection | • | • | • | • | • | • | Min 6 ft projection but not beyond a terrace; an awning covering only principal entrance may extend min 3 ft Secondary frontages | • | • | • | • | • | • | Permitted only over doors, max 6 feet projection Clearance | • | • | • | • | • | • | Min 8 ft over sidewalk or terrace, set back at least 2 ft from curb Fences and Walls Walkways | • | One per secondary entrance, max width 5 ft Building foundations | • | • | • | • | Brick stone, or stucco pier and inset fill-panel construction, or chain wall construction with panels inset to resemble pier and infill panel construction. Infill between piers shall be brick, stone, stucco, wood lattice, or vertical wood picket and shall be recessed so that piers protrude from the infill • | • | No limitations H. Stoop frontage type. 1. General characteristics. In the stoop frontage type, the building façade is aligned close to the front property line with the first story elevated from the sidewalk for privacy, and an exterior stair and landing at the building entrance. 2. Standards. Development using a stoop frontage type shall comply with the standards in table 6.11: Stoop Frontage Type Standards. Table 6.11: Stoop Frontage Type Standards Site features | Applicable Sub-districts | [image omitted; see the official code] T-6 | T-5 (both) | T-4 | T-3 | Municipal | Open | SD-WH Finished floor elevation, first floor (min/max) | [image omitted; see the official code] | • | • | • | • | 20 in/36 in (measured from average grade at property line) • | • | As required to comply with flood elevation requirements Stoop standards Stoop required | • | • | • | • | • | • | Stoop is required to be provided Elevation (min/max) | [image omitted; see the official code] | • | • | • | • | • | • | 20 in/36 in above sidewalk grade Depth (min/max) | [image omitted; see the official code] | • | • | • | • | • | • | 4 ft/6 ft Encroachment, Stoop | • | • | • | • | • | • | Stoop encroach into front setback at principal entrance or be recessed into the building façade Encroachment, Steps | Steps that provide access to porch or stoop may encroach up to property line Coverage | • | • | • | • | • | • | Optional roof structure supported by columns or wall brackets Fences and Walls General Standards | • | Iron fence with or without masonry piers at front property line is permitted Walkways Walkways | • | One permitted per entrance, with a maximum width of 5 ft Frontage Surfacing | • | Frontage may be paved up to 100 percent of area, using unit masonry or concrete I. Common entry frontage type. 1. General characteristics. In the common entry frontage type, a single point of entry is provided for multiple units or uses in a single building. A common entry frontage may include all elements of a shopfront frontage (see subsection L below) at the level of the sidewalk. 2. Standards. Development using a common entry frontage type shall comply with the standards in table 6.12: Common Entry Frontage Type Standards. Table 6.12: Common Entry Frontage Type Standards Site features | Applicable Sub-districts | [image omitted; see the official code] T-6 | T-5 (both) | T-4 | T-3 | Municipal | Open | SD-WH Finished floor elevation, first floor (min/max) | [image omitted; see the official code] | • | • | • | n/a/36 in (measured from average grade along the facade) • | • | As required to comply with flood elevation requirements Encroachment depth (max) Stairs | [image omitted; see the official code] | • | • | • | • | • | May encroach up to property line Fences and Walls General standards | • | Fence made of iron, steel, or aluminum that appears to be iron, with or without masonry piers, at front property line is permitted Awnings Material and type | • | • | • | • | • | Fabric, fixed or movable Primary frontage, span | Ground floor | • | • | • | • | • | Min 80 percent of frontage without gaps except between separate businesses. If awning covers only the principal entrance, shall be the width of the principal entrance Other floors | • | • | • | • | • | Shall cover only a window/door and match width of window/door Primary frontage, projection | [image omitted; see the official code] | • | • | • | • | • | Min 6 ft projection but not beyond a terrace; an awning covering only principal entrance may extend min 3 ft Secondary frontages | • | • | • | • | • | Permitted only over doors, max 6 feet projection Clearance | • | • | • | • | • | Min 8 ft over sidewalk or terrace, set back at least 2 ft from curb Walkways | • | One permitted per entrance, with a maximum width of 5 ft Frontage Surfacing | • | Frontage may be paved up to 100 percent of area, using unit masonry or concrete J. Pedestrian forecourt frontage type. 1. General characteristics. In the pedestrian forecourt frontage type, a portion of the facade is close to the front property line and remaining facade is set back from the front property line to create an entry courtyard. A pedestrian forecourt frontage may include all elements of: (a) A gallery frontage (see subsection L below), except within the entry courtyard; and (b) A shopfront frontage (see subsection L below) along front property lines and within the entry courtyard. 2. Standards. Development using a pedestrian forecourt frontage type shall comply with the standards in table 6.13: Pedestrian Forecourt Frontage Type Standards. Table 6.13: Pedestrian Forecourt Frontage Type Standards Site features | Applicable Sub-districts | [image omitted; see the official code] T-6 | T-5 (both) | T-4 | T-3 | Municipal | Open | SD-WH Finished floor elevation, first floor (min/max) | [image omitted; see the official code] | • | • | • | 18 in (except o in at entry) (measured from average grade along the facade) • | • | As required to comply with flood elevation requirements Entry courtyard Location | • | • | • | • | • | Principal entrance Area, max | • | • | • | 600 sq ft • | • | 1,600 sq ft Design | • | • | • | • | • | Bound by building facades on at least two sides Build out | • | • | • | • | • | The width of the entry courtyard shall count towards frontage build out (see Section 6.C.1 above) Awnings and canopies Material and type | Awning | • | • | • | • | • | Fabric, fixed or movable Canopy | • | • | • | • | • | Fixed, metal or wood Awnings and canopies, primary frontage, span | Ground floor | • | • | • | • | • | Min 80 percent of frontage without gaps except between separate businesses. If awning covers only the principal entrance, shall be the width of the principal entrance Other floors | • | • | • | • | • | Shall cover only a window/door and match width of window/door Awnings and canopies, primary frontage, projection | • | • | • | • | • | Min 6 ft projection but not beyond a terrace; an awning covering only principal entrance may extend min 3 ft May extend 12 feet across vehicular forecourt frontages or 30 feet when installed as a porte-cochere Awnings and canopies, secondary frontages | • | • | • | • | • | Permitted only over doors, max 6 feet projection Awnings and canopies, setback | • | • | • | • | • | Set back at least 2 ft from curb Clearance | • | • | • | • | • | Min 8 ft over sidewalk Frontage Surfacing | • | • | • | • | • | Frontage maybe paved up to 100 percent of area, using unit masonry or concrete ;adv=6;K. Vehicular forecourt frontage type. 1. General characteristics. In the vehicular forecourt frontage type, portion of the facade is close to the front property line and remaining facade is set back from the front property line to create an entry courtyard for vehicular access. 2. Standards. Development using a vehicular forecourt frontage type shall comply with the standards in table 6.14: Vehicular Forecourt Frontage Type Standards. Table 6.14: Vehicular Forecourt Frontage Type Standards Site features | Applicable Sub-districts | [image omitted; see the official code] T-6 | T-5 (both) | T-4 | T-3 | Municipal | Open | SD-WH Finished floor elevation, first floor (max) | [image omitted; see the official code] | • | • | 18 in (except 0 in at entry) (measured from average grade along the facade) • | • | As required to comply with flood elevation requirements Entry courtyard Location | • | • | • | • | Principal entrance Area, max | • | • | • | • | 1,600 sq ft Width, max | [image omitted; see the official code] | • | • | • | • | 50% of width of facade Design | • | • | • | • | Bound by building facades on at least two sides Surfacing | • | • | • | • | Paved or unpaved, with unit masonry or concrete Paved or landscaped • | • | All materials permitted Build out | The width of the entry courtyard shall count towards frontage build out (see Section 6.C.1 above) Awnings and canopies Material and type | Awning | • | • | • | • | Fabric, fixed or movable Canopy | Fixed, metal or wood Awnings, primary frontage, span | Ground floor | • | • | • | • | Min 80 percent of frontage without gaps except between separate businesses. If awning covers only the principal entrance, shall be the width of the principal entrance Other floors | • | • | • | • | Shall cover only a window/door and match width of window/door Awnings, primary frontage, projection | • | • | • | • | Min 6 ft projection but not beyond a terrace; an awning covering only principal entrance may extend min 3 ft Awnings, secondary frontages | • | • | • | • | Permitted only over doors, max 6 feet projection Awnings, setback | • | • | • | • | Set back at least 2 ft from curb Clearance | • | • | • | • | Min 8 ft over sidewalk L. Gallery frontage type. 1. General characteristics. In the gallery frontage type, the façade is aligned close to the front property line with an attached lightweight colonnade overlapping the sidewalk. 2. Standards. Development using a gallery frontage type shall comply with the standards in table 6.15: Gallery Frontage Type Standards. Table 6.15: Gallery Frontage Type Standards Site features | Applicable Sub-districts | [image omitted; see the official code] T-6 | T-5 (both) | T-4 | T-3 | Municipal | Open | SD-WH Finished floor elevation, first floor (max) | [image omitted; see the official code] | • | • | 18 in (except 0 in at entry) (measured from average grade along the facade) • | • | As required to comply with flood elevation requirements Gallery, general Depth, min. | [image omitted; see the official code] | • | • | • | • | 7 ft Height, min. | [image omitted; see the official code] | • | • | • | • | 12 ft Encroachment | [image omitted; see the official code] | • | • | • | • | May encroach within public right-of-way with a right-of-way permit, provided a minimum 5-ft-wide clear pedestrian path is maintained along the public sidewalk Span, min. | • | • | 80% of façade without gaps Columns | • | • | Required, centered on spandrel beam, constructed of round metal, diameter of between 3 and 6 in, with a base, shaft, and capital Column, location | [image omitted; see the official code] [image omitted; see the official code] | • | • | Min. 7 ft from façade, Min. 2 ft from curb Gallery deck, configuration | • | • | Max 9 inches thick (including all structures and surface) and exposed Gallery deck, location | • | • | Located above top of transom windows Gallery, materials | • | • | Upper story railings shall be painted metal Lighting | • | • | • | • | Where a gallery interrupts street lighting, a minimum of one-half (1/2) foot candle of lighting shall be provided within the gallery Fences and Walls Walkways | One per secondary entrance, max width 5 ft Building foundations | • | • | Brick stone, or stucco pier and inset fill-panel construction, or chain wall construction with panels inset to resemble pier and infill panel construction. Infill between piers shall be brick, stone, stucco, wood lattice, or vertical wood picket and shall be recessed so that piers protrude from the infill • | • | No limitations M. Shopfront frontage type. 1. General characteristics. (a) In the shopfront frontage type, the building facade at the ground floor is substantially glazed to provide visibility into interior spaces. Shopfronts may include display cases that project forward and recessed entries. (b) Shopfront frontages may be used alone as a frontage type or in combination with other frontage types. 2. Standards. Development using a shopfront frontage type shall comply with the standards in table 6.16: Shopfront Frontage Type Standards. In addition, ground-floor movable commercial uses may utilize the public sidewalk for seating, serving, displays of merchandise, and other business-related activities as long as a five-foot minimum clear sidewalk passage is maintained. Table 6.16: Shopfront Frontage Type Standards Site features | Applicable Sub-districts | [image omitted; see the official code] T-6 | T-5 (both) | T-4 | T-3 | Municipal | Open | SD-WH Finished floor elevation, first floor (max) | • | • | • | • | 18 in (except 0 in at entry) (measured from average grade along the facade) • | • | As required to comply with flood elevation requirements Shopfront, design Configuration | • | • | • | • | Shall be designed with a bulkhead, display window, and transom[GG1](see FIGURE A-10.a) Height (min) | [image omitted; see the official code] | • | • | • | • | 16 ft (measured from grade to top of base cornice) Bulkhead, height (min/max) | [image omitted; see the official code] | • | • | • | • | 18 in/30 in Transom windows, configuration | • | • | • | • | Include dividing muntins and no signage Signs | • | • | • | • | Individual storefront signs that are mounted onto the facade shall be installed above transom window Recessed entry | • | • | • | • | • | • | May be recessed up to 8 ft from façade Shopfront, Transparency, and coverage Transparency of shopfront area, min. | • | • | • | • | • | • | Min 50% along each frontage, calculated by the width of the frontage and the area between the sidewalk grade and bottom of the second floor or roof structure Coverage, min | Primary frontage | • | • | • | • | • | • | 80 percent of frontage length Secondary frontage | • | • | • | • | • | • | 30 percent of frontage length Gallery, materials | • | • | Upper story railings shall be painted metal Awnings and canopies [1] Material and type | Awning | • | • | • | • | • | Fabric, fixed or movable Canopy | Fixed, metal or wood Awnings, primary frontage, span | Ground floor | • | • | • | • | • | Min 80 percent of frontage without gaps except between separate businesses. If awning covers only the principal entrance, shall be the width of the principal entrance Other floors | • | • | • | • | • | Shall cover only a window/door and match width of window/door Awnings, primary frontage, projection | [image omitted; see the official code] | • | • | • | • | • | Min 6 ft projection but not beyond a terrace; an awning covering only principal entrance may extend min 3 ft Awnings, secondary frontages | • | • | • | • | • | Permitted only over doors, max 6 feet projection Awnings, setback | • | • | • | • | • | Set back at least 2 ft from curb Clearance | [image omitted; see the official code] | • | • | • | • | • | Min 8 ft over sidewalk Frontage Surfacing | • | • | • | • | Frontage may be paved up to 100 percent of area, using unit masonry or concrete [1] Awnings and canopies are only permitted on shopfront frontages that are not combined with other frontage types. 2. Standards. Development using a shopfront frontage type shall comply with the standards in Table 6.16: Shopfront Frontage Type Standards. In addition, ground-floor movable commercial uses may utilize the public sidewalk for seating, serving, displays of merchandise, and other business-related activities as long as a five-foot minimum clear sidewalk passage is maintained.

(Ord. No. 64-058-2025, 1-20-26)

Ask a question about Mobile law

Corpus searches the Mobile sections it holds and shows the ones that match, with their citations. Free, no sign-in.