§ 7 — Building design and material standards
Code of the City of Mobile, Alabama (Supp. No. 67: codified through Ordinance No. 36-017-2026, adopted March 1, 2026) · Mobile City Code, App. A, § 7
Corpus is an independent public-information project, not the official City of Mobile website. Stable reference: corpuslaw.us/code/9e345fb0-00db-45e2-962a-80763bafbfaa
Section 7. - Building design and material standards.
A. General standards. 1. All openings, including but not limited to porches, galleries, doors, and windows, with the exception of shopfronts, shall be square or vertical in proportion. 2. If multiple exterior materials are used on a single building, the materials shall be combined on each facade horizontally, with heavier material below lighter material. 3. A building shall use the following exterior finish materials: (a) Wood or cementitious clapboard; (b) Shingles; (c) Board and batten; (d) Stucco; (e) Brick; or (f) Stone. B. Orientation. A building façade shall be parallel to the primary front property line, except within 20 feet of corners, with the primary building entrance through the façade. C. Foundation standards. 1. Applicability. (a) The standards of this section apply to development in the T-3, T-4, T-5, T-6, and SD-WH sub-districts, except as provided in subsection (b) below. (b) The standards of this section do not apply to: (1) Slab-on-grade construction in the common entry, pedestrian forecourt, vehicular forecourt, gallery, and shopfront frontage types; or (2) Foundations of new additions to existing buildings, which may match the material and design of the foundation of the existing building. 2. Foundation specifications and materials. (a) Raised foundations. In the T-3, T-4, T-5, T-6, and SD-WH sub-districts, raised foundations shall be one of the following: (1) Pier and fill-panel construction; (2) Chain wall construction with panels inset to resemble pier and infill panel construction; or (3) Raised slab foundations with piers faced with brick, stone, or stucco. (b) Lattice foundations. If used in the T-3, T-4, T-5, T-6, and SD-WH sub-districts, lattice shall be hung below the skirt board or siding between the piers and framed with trim and shall not be secured to the face of the foundation. (c) Solid infill. In the T-3, T-4, T-5, T-6, and SD-WH sub-districts, solid infill between the piers shall be recessed. (d) Material standards. A building foundation shall use the materials listed as permitted in table 7.1: Foundation Materials, based on the applicable sub-district. Table 7.1: Foundation Materials Materials | T-6 | T-5 (both) | T-4 | T-3 | Municipal | Open | SD-WH Brick | • | • | • | • | • | • | • Stone | • | • | • | • | • | • | • Stucco | • | • | • | • | • | • | • Metal infill | • | • Plywood panels | • | • Mineral board panels | • | • Plastic or vinyl sheeting | • | • Unfinished concrete block | • | • Wood piers | • | • Imitation brick or stone | • | • Vinyl lattice | • | • • = Permitted D. Transparency standards. 1. Except for buildings located in a SD-WH district fronting Beauregard Street between Saint Joseph Street, North Water Street and North Lawrence Street, all building Facades along public frontages shall have a minimum of twenty (20) percent transparency measured on each floor, except as otherwise provided in this appendix for specific frontage types. 2. Reflective glass may not be used to meet the standards of this subsection D within the first six (6) stories above ground level. 3. Opaque and spandrel glass may not be used to meet the transparency standards of this subsection D. 4. Tinted glass may be used, provided the visible transmittance rating is no less than the minimum required to meet the standards of the building code. In lieu of tinting, the use of awnings to address solar gain is preferred. 5. Security bars on windows or doors shall not be visible from the street. E. Roof standards. A roof shall use the materials listed as permitted in table 7.2: Roof Materials, based on the applicable sub-district. Table 7.2: Roof Materials Materials | T-6 | T-5 (both) | T-4 | T-3 | Municipal | Open | SD-WH Tile | • | • | • | • | • | • | • Standing seam metal | • | • | • | • | • | • | • Metal shingles | • | • | • | • | • | • | • Five v-crimp | • | • | • | • | • | • | • Asphalt, fiberglass, cement fiber, wood, or slate shingles | • | • | • | • | • | • | • Built-up or membrane roofing | 1 | 1 | 1 | 1 | 1 | 1 | 1 Corrugated fiberglass | • | • Asphalt roll roofing | • | • Corrugated metal | • | • Panel and batten | • | • Colored metal | • | • All other materials | • | • • = Permitted [1] Build-up or membrane roofing shall only be used on roofs with slopes less than 3:12 rise:run where hidden from view from the public right-of-way.
(Ord. No. 64-058-2025, 1-20-26)
Ask a question about Mobile law
Corpus searches the Mobile sections it holds and shows the ones that match, with their citations. Free, no sign-in.
