For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 64-3-6 — Building design and height

Code of the City of Mobile, Alabama (Supp. No. 67: codified through Ordinance No. 36-017-2026, adopted March 1, 2026) · Mobile City Code § 64-3-6

Corpus is an independent public-information project, not the official City of Mobile website. Stable reference: corpuslaw.us/code/8f038eb9-4d7d-48f1-b2a7-d062761b1fc2

Sec. 64-3-6. - Building design and height.

A. Applicability. 1. Every new multi-family, commercial, maritime and mixed use building must include at least one feature from each of the following categories: (a) Site frontage; (b) Building form—Height; (c) Building form—Wall; and (d) Architectural feature. B. Site frontage. 1. This section establishes how the primary facade of a building relates to an abutting street or parking lot. 2. The site frontage must extend across the entire building frontage. (a) Pedestrian courtyard. Figure 64-3-6.1 Pedestrian Courtyard Frontage Type [image omitted; see the official code] (1) Requirements: a. The entry courtyard shall be located at the primary entrance. b. The width of the entry courtyard counts toward frontage build out. c. Courtyards shall recess no more than fifty (50) percent of the building facade. d. Courtyards shall be enclosed on three sides by the building facade. e. Courtyards shall be a minimum depth of eight (8) feet. (b) Vehicular courtyard. Figure 64-3-6.2 Vehicular Courtyard Frontage Type [image omitted; see the official code] (1) Requirements: a. Courtyards shall recess no more than fifty (50) percent of the building facade. b. Courtyards shall be a minimum depth of eight (8) feet. c. Courtyards shall be enclosed on three (3) sides by the building facade. (c) Landscape area. (1) Requirements: a. The landscape area shall be a minimum depth of any required setback or five (5) feet, whichever is greater, and may extend to the front property line. (2) Lawn. (3) Mixed vegetation. (d) Patio area. (1) Requirements: a. The patio area shall be a minimum depth of any required setback or five (5) feet, whichever is greater, and may extend to the front property line. (e) Sidewalk frontage. (f) Terrace. Figure 64-3-6.3 Terrace Frontage Type [image omitted; see the official code] (1) Requirements: a. The terrace shall be a minimum of eight (8) feet deep and may extend to the front property line. C. Building form. 1. The building form section establishes the criteria for building articulation as it relates to height or shape. Every new building must include a minimum of one (1) height variation, and one (1) wall variation. 2. Height variation. (a) Height elements: (1) Pitched roof element. (2) Raised parapet. (3) Tower. (b) Requirements: (1) A variation in building or parapet height of at least two (2) feet or four (4) feet for Buildings greater than twenty-four (24) feet in height. (2) Use of more than one (1) roof form to divide the building into different building modules. Figure 64-3-6.4 Tower/Raised Parapet/Pitch Roof Element Frontage Type [image omitted; see the official code] (c) Height exceptions: (1) The height limits for the zoning districts do not apply to: a. Spires, belfries, cupolas, penthouses or domes not used for human habitation; chimneys, ventilators, skylights, water tanks, parapet walls, cornices, radio and television receiving antennas or necessary mechanical appurtenances usually carried above the roof level; these features are limited to that height necessary for their proper functioning. 3. Wall variation. (a) Wall elements and requirements: (1) Notch. (2) Offset. (3) Projection. D. Architectural feature. 1. Arcade/colonnade/gallery. (a) Requirements. Arcades, colonnades and galleries shall conform to the following minimum specifications: (1) Minimum clear width from the interior face of the support columns to the building's primary facade is ten (10) feet; (2) Minimum clear height of at least ten (10) feet above the sidewalk; (3) Maximum spacing: no further than column's height (measured from finished surface to the top of the column); and (4) Minimum horizontal extension over the facade width (measured from the edge of the furthest columns) is seventy-five (75) percent. (b) Options: (1) Arcades, colonnades and galleries may include all elements of a storefront frontage. Figure 64-3-6.5 Arcade/Colonnade/Gallery Frontage Type [image omitted; see the official code] 2. Awning/canopy/marquee. (a) Over ground-story doors or windows a depth of at least five (5) feet, and a clear height of at least eight (8) feet above the sidewalk are required. 3. Balcony. Figure 64-3-6.6 Balcony Frontage Type [image omitted; see the official code] (a) Requirements: (1) Balconies shall have a minimum depth of three (3) feet and a maximum depth of six (6) feet from the facade; (2) Balconies shall have a clear height of at least ten (10) feet above the sidewalk; and (3) Balconies must be open toward the street or primary frontage. (b) Options: (1) Balconies may have roofs. (2) Balconies may extend into the right-of-way; however a right-of-way non-utility use agreement and right-of-way permit are required. 4. Porch. (a) Requirements: (1) Front porches shall be a minimum eight (8) feet deep; (2) Front porches are required to be open and un-air-conditioned; (3) Partial walls and railings on porches shall comply with the current building code adopted by the city; and (4) Porches may not extend into the right-of-way. 5. Projected or recessed entry. Figure 64-3-6.7 Recessed or Projected Entry Frontage Type [image omitted; see the official code] [image omitted; see the official code] (a) Requirements: (1) The entry shall extend vertically at least fifteen (15) feet or to the top of the front elevation and with a continuous width of at least twelve (12) feet at all points along the required vertical dimension. 6. Stoop. Figure 64-3-6.8 Stoop Frontage Type [image omitted; see the official code] (a) Requirements: (1) Stoops shall be between four (4) and six (6) feet deep; and (2) Partial walls and railings on stoops shall comply with the current building code adopted by the city. 7. Storefront. (a) Requirements: (1) The storefront area is calculated by multiplying the width of the building frontage by the ground floor height; and (2) Storefronts shall provide transparent windows for at least fifty (50) percent of the storefront facade, calculated separately for each building frontage.

(Ord. No. 64-017-2022, 7-12-22)

Ask a question about Mobile law

Corpus searches the Mobile sections it holds and shows the ones that match, with their citations. Free, no sign-in.