§ 172.04 — Parking Lot Design Standards
Code of Ordinances of the City of Fayetteville, Arkansas (Codified through Ordinance No. 7010, enacted June 16, 2026 (Supp. No. 42)) · Fayetteville Code of Ordinances § 172.04
Corpus is an independent public-information project, not the official City of Fayetteville website. Stable reference: corpuslaw.us/code/6757f5a4-72c7-473d-a177-a60561c27e5b
172.04 - Parking Lot Design Standards
(See: Illustration: Parking Dimension Factors) (A) Maneuvering. Parking lots shall be designated, maintained, and regulated so that no parking or maneuvering incidental to parking will encroach into the areas designated for sidewalks, streets, or required landscaping. Parking lots shall be designed so that parking and un-parking can occur without moving other vehicles, unless a valet service has been approved as part of the development plans. Vehicles shall exit the parking lot in a forward motion. (B) Pedestrian Access. (1) Pedestrian access shall be provided from the street to the entrance of the structure by way of designated pathway or sidewalk. (2) Parking lots may be utilized by restaurants, cafes, and similar uses where pedestrian seating, access, or service does not interfere with safe and functional circulation. If a parking lot utilized for outdoor service is determined to represent a hazard to pedestrian or vehicular use, sites may be required to include an implied or physical barrier with landscaping elements, gated fencing, changes in ground surface texture, material or color, or similar treatments. (C) Build-to Zone. A portion of a required parking lot may be located within the build-to zone, subject to the following: (1) A parking lot located within the build-to zone shall be screened with a masonry screen wall between 32 inches and 42 inches in height and 50% opaque minimum. (2) Parking lots that are located within the build-to zone shall comply with Chapter 177: Landscape Regulations, related to landscape setbacks. (3) Off-site parking lots shall be prohibited from being located within the build-to zone. (4) In urban zoning districts that specify urban form (i.e., a build-to zone) the intent is for drive-thru lanes, parking lot drive aisles, and parking spaces to be located to the side or rear of buildings. In urban zoning districts, a drive-thru lane, parking lot drive aisle, or parking spaces are not permitted to be located in the front yard directly between a building and the Master Street Plan right-of-way. (D) Compact Spaces. A maximum of 35% of the total spaces are allowed to be compact spaces for nonresidential uses and a maximum of 20% are allowed to be compact spaces for residential parking. Compact spaces shall be marked either by marking on the pavement or by separate marker. (E) Dimensional Requirements. (See Table 1) TABLE 1 DIMENSIONAL REQUIREMENTS Angle (A) | Type | Width (in ft.) (B) | Curb length (in ft.) (C) | One-way aisle width (in ft.) (D) | Two-way aisle width (in ft.) (D) | Stall depth (in ft.) E) 0° | Standard | 8 | 22.5 | 12 | 24 | 8 Parallel | Compact | 7.5 | 19.5 | 12 | 24 | 7.5 30° | Standard | 9 | 18 | 12 | 24 | 17 Compact | 8 | 15 | 12 | 24 | 14 45° | Standard | 9 | 12.5 | 12 | 24 | 19 Compact | 8 | 10.5 | 12 | 24 | 16 60° | Standard | 9 | 10.5 | 18 | 24 | 20 Compact | 8 | 8.5 | 15 | 24 | 16.5 90° | Standard | 9 | 9 | 24 | 24 | 19 Compact | 8 | 7.5 | 22 | 24 | 15 Motorcycle/Scooter | 3 | 3 | 12-24 | 24 | 7.5—9 DIMENSIONAL FACTORS [image omitted; see the official code] (F) Parking Lot Circulation. (1) Throat Length. The length of driveways or "throat length" shall be designed in accordance with the anticipated storage length for vehicles to prevent them from backing into the flow of traffic on the public street or causing unsafe conflicts with on-site circulation. General standards appear below, but these requirements may vary according to the project volume of the individual driveway. These measures generally are acceptable for the principal access to a property and are not intended for minor driveways. Variation from these standards may be permitted for good cause upon approval of the Zoning and Development Administrator and City Engineer. TABLE 2 GENERALLY ADEQUATE DRIVEWAY THROAT LENGTHS Shopping Centers (Signalized) | >200,000 GLA* (800) spaces | 200 ft. Smaller Developments (Signalized) | <200,000 GLA* | 75—95 ft. Unsignalized Driveways | — | 40—60 ft. *GLA-Gross leaseable area [image omitted; see the official code] Commentary: The throat lengths in Table 2 are provided to assure adequate stacking space within parking lot driveways for general land use intensities. This helps prevent vehicles from stacking into the thoroughfare as they attempt to enter the parking lot. High traffic generators, such as large shopping plazas, need much greater throat length than smaller developments or those with unsignalized driveways. The guidelines here for larger developments refer to the primary access drive. Reduced throat lengths may be permitted for secondary access drives serving large developments. (2) Drive-Through Facilities. All uses that include a drive-up window or are characterized by patrons remaining in their vehicles to receive service shall meet the following on-site stacking requirements in order to alleviate traffic congestions: (a) Restaurant, fast food: a minimum of four (4) spaces as measured from the drive-thru window (b) Vehicular washes: a minimum of two (2) spaces per car wash bay as measured from the bay. (c) Pharmacies and financial institutions: a minimum of four (4) spaces for one (1) drive-thru window, plus three (3) spaces for each additional drive-thru lane or automated teller machine (ATM), as measured from each drive-thru window. (d) Dry cleaning and laundry services: a minimum of two (2) spaces as measured from the drive-thru window. (3) Entrances and Internal Aisle Design for Parking Lots Containing 8 Parking Spaces or Less. The driveway width into parking lots shall meet the following requirements: (a) Entrances. (i) One-Way Access to Parking Lots. If the driveway is a one-way in or one-way out, then the driveway width shall be a minimum of 12 feet and a maximum of 16 feet. Parking lots shall not be located more than 100 feet from the street right-of-way. Commercial solid waste service is required. (ii) Two-Way Access to Parking Lots. For two way access, the driveway width shall be a minimum of 12 feet and a maximum of 24 feet. Parking lots shall not be located more than 100 feet from the street right-of-way. This standard shall only apply when a 2-yard dumpster is allowed. (iii) Driveway Width Requirements for Parking Lots Located 100 Feet or More from the Street Right-of-Way. Two (2) drive lanes a minimum width of 10 feet each, up to a maximum combined width of 24 feet, shall be required for adequate parking lot access. (iv) Effective Curb Radius. All driveway entrances serving 8 or less parking spaces shall have a minimum effective curb radius of 10 feet and a maximum of 20 feet. (b) Internal aisle design. (i) Aisles shall be designed so that they intersect at 90 degrees with other aisles and driveways where practical. (ii) Aisles shall be designed to discourage cut-through traffic by use of landscape islands, and shall meet the requirements of Chapter 177: Landscape Regulations. (iii) Aisles shall conform to the dimensional requirements of §172.04(C). (c) Variances. Development proposals which do not meet these standards may apply for a variance from these requirements subject to Planning Commission approval. Parking Lots With Eight (8) Spaces or Less Driveway Dimensional Requirement One Way Access <100 feet | 12 feet Minimum - 16 feet Maximum Two Way Access <100 feet | 12 feet Minimum - 24 feet Maximum >100 feet Driveway Length | 2 Drive Lanes 10 feet Minimum Each - 24 feet Maximum Total Driveway Width Effective Curb Radius | 10 feet Minimum - 20 feet Maximum (4) Entrances and Internal Aisle Design for Parking Lots Containing Nine (9) or More Parking Spaces. The driveway width into parking lots shall meet the following requirements: (a) Entrances. (i) One-Way Access to Parking Lots. If the driveway is a one-way in or one-way out, then the driveway width shall be a minimum of 12 feet and a maximum of 16 feet. (ii) Two-Way Access to Parking Lots. For two (2) way access, the driveway width shall be a minimum 20 feet and a maximum width of 24 feet, unless otherwise required by the Fire Department. (iii) Neighborhood and Regional Links. Driveways that enter neighborhood and regional link streets may be required to have two (2) outbound lanes (one (1) for each turning direction) and one (1) inbound lane for a maximum total driveway width of 39 feet. (iv) Effective Curb Radius. All driveways serving nine (9) or more parking spaces shall have an effective curb radius of 15 feet for curb cuts on residential link streets and an effective curb cut radius of 20 feet for neighborhood and regional link streets. (b) Internal Aisle Design. (i) Aisles shall be designed so that they intersect at 90 degrees with other aisles and driveways where practical. (ii) Aisles shall be designed to discourage cut-through traffic by use of landscape islands, and shall meet the requirements of Chapter 177: Landscape Regulations. (iii) Aisles shall conform to the dimensional requirements of §172.04(C). Parking Lots With Nine (9) Spaces or More Driveway Dimensional Requirement One Way Access | 12 feet Minimum - 16 feet Maximum Two Way Access | 2 Drive Lanes 10 feet Minimum Each - 24 feet Maximum Total Driveway Width Neighborhood/Regional Link | 3 Drive Lanes - Maximum of 39 feet Effective Curb Radius - Residential Link | 15 feet Effective Curb Radius - Neighborhood/Regional Link | 20 feet (G) Hillside/Hilltop Overlay District. (1) Separation of Parking Pads in Multi-Family, and Non-Residential Development. Parking pads shall be separated by a minimum undisturbed area of 15 feet between parking pads. Streets and access drives are permitted to cross this undisturbed area. (2) Cut and Fill Slopes. Parking pads should be encouraged to utilize cut slopes with retaining walls to minimize disturbance. (3) Maximum Number of Spaces per Parking Lot for Multi-Family and Non-Residential Uses. Parking pads shall have a maximum of thirty (30) spaces per pad. (4) Parking Lot Location. Parking lots shall be setback with a minimum of 35 feet of undisturbed area required adjacent to the street right-of-way. (5) Multi-Family and Non-Residential Uses. Developers of multi-family and non-residential uses in the Hillside Overlay District are encouraged to refer to the Hillside Best Management Practices Manual for guidance and direction in the design of their project.
(Ord. No. 4725, 7-19-05; Ord. No. 4855, 4-18-06; Ord. No. 4917, 9-05-06; Ord. No. 5044, 8-07-07; Ord. No. 5079, 11-20-07; Ord. No. 5297, 12-15-09; Ord. No. 5592, 06-18-13; Ord. No. 5680, 4-15-14; Ord. No. 5841, §§1—3, 1-5-16; Ord. No. 5859, §2, 3-15-16; Ord. No. 6325, §1, 6-16-20; Ord. No. 6350, § 9(Exh. G), 8-18-20; Ord. No. 6864, §1, 5-6-25)
Ask a question about Fayetteville law
Corpus searches the Fayetteville sections it holds and shows the ones that match, with their citations. Free, no sign-in.