For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 172.05 — Standards For The Number Of Spaces By Use

Code of Ordinances of the City of Fayetteville, Arkansas (Codified through Ordinance No. 7010, enacted June 16, 2026 (Supp. No. 42)) · Fayetteville Code of Ordinances § 172.05

Corpus is an independent public-information project, not the official City of Fayetteville website. Stable reference: corpuslaw.us/code/5bff64e1-4e0a-4374-bff7-c9e29b907292

172.05 - Standards For The Number Of Spaces By Use

(A) Non-Residential Parking Requirements. There shall be no minimum number of spaces required for non-residential use. The maximum number of spaces provided shall be limited to the ratios in Table 3 and the allowable increases over the baseline ratio as described in §172.05(3). The applicant shall provide a statement or parking analysis indicating how they will provide adequate parking for the proposed non-residential use to succeed without negatively impacting adjacent properties or creating or compounding a dangerous traffic condition. (B) Residential Parking Requirements. The minimum and maximum number of spaces required for residential use shall conform to the parking ratios listed in Table 3. The minimum and maximum number of spaces required for a use not specifically included in this section shall be as required for the most similar use listed or as otherwise determined by the Planning Division utilizing reference standards. (1) Reductions for Residential Use. Residential uses may utilize the following reductions to the minimum number required off-street parking ratios listed in Table 3. If the applicant does not provide the number of parking spaces allowed by Table 3, the applicant shall provide for approval by the Zoning and Development Administrator relevant parking utilization data or a parking analysis demonstrating how they will provide adequate parking for the proposed residential use to succeed without negatively impacting adjacent properties or creating or compounding a dangerous traffic condition. The statement or analysis shall address factors such as abutting street widths, existing parking conditions, parking reductions already claimed by nearby residential and commercial developments, potential and compounding impacts on surrounding neighborhoods and commercial districts, existing use of on-street parking, capacity for additional on-street parking, density of existing buildings, emergency vehicle access, fire safety, and whether existing properties have off-street parking available. (a) Developments with 1—50 bedrooms may be allowed a maximum reduction of 35% of the total required spaces without being required to apply for consideration and approval by the Planning Commission. (b) Developments with 51—100 bedrooms may be allowed a maximum reduction of 20% of the total required spaces without being required to apply for consideration and approval by the Planning Commission. (c) Developments with 101—250 bedrooms may be allowed a maximum reduction of 15% of the total required spaces without being required to apply for consideration and approval by the Planning Commission. (d) Developments with two hundred fifty-one (251) or more bedrooms may be allowed a maximum reduction of 10% of the total required spaces without being required to apply for consideration and approval by the Planning Commission. (e) Multi-family and mixed-use developments that include multi-family along N. College Ave. and S. School Ave. within the Urban Corridor (UC) zoning district may be allowed an additional reduction of 10% of the total spaces required without being required to apply for consideration and approval by the Planning Commission. (2) Criteria for Consideration of Additional Reductions for Residential Use by the Planning Commission. Applicants may request parking space reductions for residential use in addition to those listed in §172.05(B)(1) subject to the requirements in §156.03(C)(5). In reviewing the requested parking variance, the Planning Commission shall utilize the criteria in §172.05(B)(1) to evaluate the request, and may consider factors such as proximity to transit stops, provision of covered and secured storage for bicycles, and other means of alternative transportation. The Planning Commission shall be limited to granting a maximum reduction of 35% total or four (4) spaces, whichever is greater, for developments described in §172.05(B)(1). (C) Review of Parking Plan. If an application for a residential use was approved for a reduction in required parking and the project is being considered by the Planning Commission, a Planning Commissioner may move that the Planning Commission review the decision by the Zoning and Development Administrator concerning the adequacy and correctness of the applicant's proposed parking plan pursuant to the factors in §172.05(B)(1). If this motion passes, the Planning Commission may review and amend the Zoning and Development Administrator's decision. However, the Planning Commission may not reduce the mandatory minimum parking reductions granted by the Zoning and Development Administrator for a development of fifty (50) or fewer bedrooms. (D) Shared Parking. Parking requirements may be shared where it can be determined that the peak parking demand of the existing or proposed occupancy occur at different times (either daily or seasonally). Such arrangements may be approved by the Zoning and Development Administrator if they meet the conditions below: (1) Shared Parking Between Developments. Formal arrangements that share parking between intermittent uses with non-conflicting parking demands (e.g., a church and a bank) are allowed as a means to reduce the amount of parking required. (2) Shared Parking Agreements. If a privately owned parking facility is to serve two (2) or more separate properties, then a "Shared Parking Agreement" is to be filed with the city for consideration by the Zoning and Development Administrator. (3) Shared Spaces. Individual spaces identified on a site plan for shared users shall not be shared by more than one (1) user at the same time. (E) Maximum Number of Parking Spaces Allowed for Residential and Non-Residential Uses. Residential and non-residential developments may utilize the following increases to the maximum number of allowed spaces listed in Table 3 when the following standards are met: (1) Developments may increase the number of off-street parking spaces by up to 15% above the parking ratios listed in Table 3. (2) Developments may increase the number of off-street parking spaces by up to an additional 10% when alternative stormwater treatment techniques are utilized, such as: (a) Bioswales; (b) Constructed wetlands; (c) Pervious pavement; and (d) Other such techniques that aid in improving water quality and quantity as approved by the City Engineer. (3) Developments may increase the number of off-street parking spaces by up to an additional 5% when one (1), 2-inch caliper tree for every ten (10) additional parking spaces is planted on-site in addition to all other landscaping requirements. (F) Parking Ratio Calculation. The number of spaces required for a use not specifically included in Table 3 shall be as required for the most similar use listed or as otherwise determined by the City Planning Division utilizing industry standards. For all parking space requirements resulting in a fraction, the fraction shall be: (1) Rounded to the next higher whole number when the fraction is 0.5 or higher. (2) Rounded to the next lower whole number when the fraction is less than 0.5. (G) On-Street Parking. Each on-street parking space adjacent to a project frontage that complies with adopted fire code may count toward the parking requirements for all development. The approval of on-street parking is subject to approval by the Zoning and Development Administrator. (H) Increases or reductions in excess of those identified herein shall be allowed only by the Planning Commission as a variance and shall be granted in accordance with Chapter 156.03. TABLE 3 PARKING RATIOS (Use and Required Minimum and Maximum Spaces) Residential Residential Use Type | Minimum Parking Spaces Required | Maximum Parking Spaces Allowed Single-family | 2 per dwelling unit | None Duplex, triplex, or quadplex | 2 per dwelling unit | 4 per dwelling unit Townhouse | 2 per dwelling unit or 1 per bedroom, whichever is greater | 1 per bedroom Multi-family | 1 per bedroom | 1 per bedroom TABLE 3 PARKING RATIOS (Use and Allowed Minimum and Maximum Spaces) Non-Residential Commercial Agricultural supply | 1 per 500 sq. ft. of GFA Amusement | 1 per 200 sq. ft. of GFA Auditorium | 1 per 4 seats Auto/motorcycle service stations | 4 per each enclosed service bay Bank | 1 per 200 sq. ft. of GFA Barber or beauty shop | 2 per chair Building/home improvement supply | 1 per 500 sq. ft. of GFA Coin-operated laundry | 1 per 3 machines Dry cleaning | 1 per 300 sq. ft. of retail area and 1 per employee Hotels and motels | 1 per guest room, plus 75% of spaces required for accessory uses. Furniture and carpet store | 1 per 500 sq. ft. of GFA Plant nursery | 1 per 1,000 sq. ft of indoor/outdoor retail area Restaurants | 1 per 100 sq. ft. GFA plus 4 stacking spaces per drive-thru window. Retail | 1 per 250 sq. ft. of GFA Retail fuel sales with convenience stores | 1 per 250 sq. ft. of retail floor area. Owner may count spaces at pump islands as parking spaces. Retail fuel sales only | 1 per employee. Owner may count spaces at pump islands as parking spaces. Office Medical/Dental office | 1 per 250 sq. ft. of GFA Professional office | 1 per 300 sq. ft. of GFA Sales office | 1 per 200 sq. ft. of GFA Public and Institutional Uses Nonprofit Commercial Art gallery, library, museum | 1 per 1,000 sq. ft. of GFA Auditorium | 1 per 4 seats, provided only auditorium space is counted in determining parking Child care center, nursery school | 1 per employee plus on-site loading and unloading spaces at a rate of 1 per 10 children accommodated Church/religious institution | 1 per 4 seats in the main auditorium or 1 per 40 sq. ft. of assembly area, whichever provides more spaces College auditorium | 1 per 4 seats College dormitory | 1 per sleeping room College or university | 1 per 500 sq. ft. of classroom area Community center | 1 per 250 sq. ft. of GFA Cooperative housing | 1 per 2 occupants Convalescent home, assisted living, nursing home | 1 per 2 beds Detention home | 1 per 1,500 sq. ft. of GFA Elderly Housing | 1 per 2 units Funeral homes | 1 per 4 seats in main chapel plus 1 per 2 employees plus 1 reserved for each vehicle used in connection with the business Government facilities | 1 per 500 square feet of floor area Hospital | 1 per bed Convalescent home | 1 per bed School—elementary and junior high | 1 per employee plus 1 space per classroom School—senior high | 1 per employee plus 1 per 3 students based on design capacity, or 1 per 6 seats in auditorium or other places of assembly, whichever is greater Zoo | 1 per 2,000 sq. ft. of land area All other public and institutional uses (only auditorium space shall be counted for churches, auditoriums, or group occupancy space) | 1 per 4 occupants Manufacturing/Industrial Manufacturing | 1 per 1,200 sq. ft. of GFA or one per employee, whichever is greater Heavy industrial | 1 per 1,200 sq. ft. of GFA Extractive uses | Adequate for all employees, trucks, and equipment Recreational Uses Amusement park, miniature golf | 1 per 1,000 sq. ft. of site area Bowling alley | 6 per lane Commercial recreation | 1 per 200 sq. ft. of GFA Commercial recreation-large sites | 1 per 1,000 sq. ft. of site area Dance hall, bar or tavern | 1 per 50 sq. ft. of GFA, excluding kitchen Golf course | 3 per hole Golf driving range | 1 per tee box Health club, gym | 1 per 150 sq. ft. of GFA Regional or community park | 2 per acre of accessible active and passive space Neighborhood park | None Private club or lodge | 1 per 500 sq. ft. of GFA or 1 per 3 occupants based on the current adopted Standard Building Code whichever is greater Riding stable | 1 per acre; not required to be paved Tennis court | 2 per court Theater | 1 per 4 seats All other recreational uses | 1 per 4 occupants Warehousing and Wholesale Warehousing | 1 per 2,000 sq. ft. of GFA Wholesale | 1 per 1,000 sq. ft. of GFA Center for collecting recycled materials | 1 per 1,000 sq. ft. of GFA

(Ord. No. 4567, 05-04-04; Ord. No. 4930, 10-03-06; Ord. No. 5118, 3-18-08; Ord. No. 5297, 12-15-09; Ord. No. 5435, 8-16-11; Ord. No. 5801, §1(Exh. A), 10-6-15; Ord. No. 6864, §2(Exh. A), 5-6-25; Ord. No. 6879, §6, 5-20-25; Ord. No. 6956, §1(Exh. A), 1-6-26)

Ask a question about Fayetteville law

Corpus searches the Fayetteville sections it holds and shows the ones that match, with their citations. Free, no sign-in.