§ 173.02 — Fire Prevention Code/Building Code

Code of Ordinances of the City of Fayetteville, Arkansas (Codified through Ordinance No. 7010, enacted June 16, 2026 (Supp. No. 42)) · Fayetteville Code of Ordinances § 173.02

Corpus is an independent public-information project, not the official City of Fayetteville website. Stable reference: corpuslaw.us/code/1bb266e1-735b-4154-a0f8-ff9c9ad71615

173.02 - Fire Prevention Code/Building Code

(A) Adoption by Reference. There is hereby adopted by the City Council, by reference thereto, the provisions set forth in the Arkansas Fire Prevention Code, with state adopted appendices, as may from time to time hereafter be amended and adopted by the State of Arkansas, save and except such portions of said code as may be deleted, modified, or amended herein. (B) Amendments, Additions, and deletions to the Building Code. The Building Code shall be amended as follows: (1) Construction Documents. Plans reviewed for code compliance with permits issued shall be destroyed after construction is complete and as allowed by law after being copied for permanent record and maintained by the city. Plans retained on file for one (1) through four (4) family residential dwelling units will be destroyed when construction is complete and may not be permanently copied. (a) Plans. Plans submitted to be reviewed for code compliance and permitting shall note the following: (i) Construction type; (ii) Occupancy classification(s); (iii) Occupant load; (iv) Design live loads; (v) Design dead loads; (vi) Occupancy and tenant separations; (vii) Design snow load; and (viii) Design wind load. (b) Plan Review. A plan review by an independent entity may be required by a building official for plans of unusual, special, and/or hazardous use of buildings submitted for permit or review. (2) Footings and Foundations. Building, structures, and parts thereof shall be designed and constructed in accordance with strength design, load and resistance factor design, allowable stress design, empirical design, or conventional construction methods, as permitted by the applicable material chapters of the Arkansas Fire Prevention Code and this section. (a) Design Requirements. (i) The footing bottoms shall be a minimum of 24 inches below finish grade; and (ii) The minimum width of a concrete footing for one (1) story building with 1,400 or less square feet shall be 18 inches. The minimum width of a concrete footing for two (2) story buildings and buildings greater than 1,400 square feet shall be 24 inches. All footings shall be reinforced with horizontal steel rebar; and (iii) Minimum footing rebar size shall be two #4's in an 18-inch footing and three #4's in a 24-inch footing each tied perpendicular to the #4 rebar spaced no more than 24 inches on center, and supported three inches from the bottom of the footing spaced no more than six feet or approved by the building official; and (iv) The thickness of the concrete footing shall be a minimum of 12 inches with a minimum of 3,000 PSI concrete; and (v) Minimum concrete footing for concentrated load shall be 24 inches × 24 inches × 12 inches in depth of 3,000 PSI concrete, 24 inches to bottom below finish grade with a rebar mat of four #4's supported three inches from the bottom with support as approved by the building official; or (vi) Designed by an Arkansas registered professional architect or engineer. (b) Design Requirements for Buildings Located in the Hillside/Hilltop Overlay District. A builder of a single-family residence, duplex or other residential, commercial or institutional structure not within a preliminary plat or large scale development shall have the foundation plans designed, approved and sealed by a professional engineer or architect. Accessory structures that do not serve as dwelling units are exempt from this foundation requirement. (3) Concrete Floors. (Slabs on grade). (a) Minimum Requirement. Minimum requirement for concrete slab-on-grade floors shall be constructed in accordance with the Arkansas Fire Prevention Code, and shall be at least eight inches above the finish grade surrounding the building; and (b) Minimum Compressive Strength. Concrete used in the construction of floors shall have a minimum compressive strength of three thousand (3,000) pounds per square inch; or (c) Design. Designed by an Arkansas registered professional architect or engineer. (4) Crawl Space. Crawl space grade shall not be lower than finish grade outside of a building without construction of a drainage remedy approved by the Building Official. (5) Signs. The City of Fayetteville adopted sign ordinance shall take precedence over conflicts with the Building Code outdoor display and signs requirements. (6) Portable Buildings. Requirements for building permits shall not apply to small one (1) story portable buildings with an area of 80 square feet or less, but shall be subject to other applicable city requirements. (7) Reroofing. Reroofing of existing residential dwelling units including detached garages and portable buildings shall not require a permit. However, the project is not exempt from meeting all code requirements. (8) Issuance of New Building Permit for Unfinished Project. No new building permits may be issued for property for which a building permit has expired unless approved by the Building Official for good cause shown by the applicant and adequate assurance that the project will be completed within the time frame authorized by the Building Official. (C) Amendments, Additions, and Deletions to the Fire Prevention Code. The Fire Prevention Code shall be amended as follows: (1) Sprinklers. In addition to the requirements of the Fire Prevention Code and the Building Code, any new building or alteration, addition or change of occupancy of existing buildings which exceeds three (3) stories including the basement, or 50 feet or greater in height at the highest point of said building shall be protected by a complete automatic sprinkler system designed and installed with compliance to applicable NFIPA Standards. The following, as defined by Fire Prevention and Building Codes, shall be exempt from this provision: (a) Airport control tower; (b) Open parking decks; (c) F-2 occupancy. (2) 912.2.3 Proximity to Hydrant. Fire Department connections for each sprinkler or standpipe system shall be located not more than 100 feet from the nearest fire hydrant connected to an approved water supply, measured along the path of vehicle travel unless otherwise approved by the fire code official. (3) 907.2.8.4 Occupant Notification for R-1 Occupancies which Include Hotels, Motels and Boarding Houses with More than Ten (10) Occupants. Notification devices are required in all sleeping units/bedrooms in accordance with 907.5 when a sprinkler and/or fire alarm system is required by other sections of this code and shall activate throughout the notification zones upon waterflow switch or detector activation. Sleeping units shall include bedrooms. (4) 907.2.9.4 Occupant Notification for R-2 Occupancies which Include Apartments, College Housing (Fraternities and Sororities) and Dormitories. Notification devices are required in all sleeping units/bedrooms in accordance with 907.5 when a sprinkler and/or fire alarm system is required by other sections of this Code and shall activate throughout the notification zones upon waterflow switch or detector activation. Sleeping units shall include bedrooms.

(Ord. No. 4100, §2 (Ex. A), 6-16-98; Ord. No. 4855, 4-18-06; Ord. No. 5019, 5-15-07; Ord. No. 5308, 3-16-10; Ord. No. 6206, §§3, 4, 7-16-19; Ord. No. 6471, §1, 9-7-21; Ord. No. 6927, §§1, 2, 11-4-25; Ord. No. 6928, §§1, 2, 11-4-25)

Ask a question about Fayetteville law

Corpus searches the Fayetteville sections it holds and shows the ones that match, with their citations. Free, no sign-in.