§ 25-167 — Definitions
Municipal Code of the City of Fort Smith, Arkansas (Codified through Ordinance No. 126-24, enacted December 3, 2024. (Supp. No. 4)) · Fort Smith Municipal Code § 25-167
Corpus is an independent public-information project, not the official City of Fort Smith website. Stable reference: corpuslaw.us/code/d80534e7-bd4f-480a-a693-8cf06e2b0940
Sec. 25-167. - Definitions.
The following words, terms and phrases, when used in this division, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: Approving authority means the city administrator or his designated agent. Auxiliary water supply means any water supply, on or available, to the property other than the public water system. Backflow means the flow of water or other liquids, mixtures or substances, under positive or reduced pressure in the distribution pipes of a potable water supply from any source other than its intended source. Backflow prevention assembly means the mechanical check valve assembly with shut-off valves, and provided as a complete assembly by a single manufacturer, used to prevent the backflow of contaminants or pollutants into the public water system. The assembly must have the approval of the state department of health and the city. Typical backflow prevention assemblies are detector double check valve assembly, detector reduced check valve assembly, double check valve assembly and reduced pressure zone assembly. Backflow prevention device means the mechanical backflow preventer without the shut-off valves. It does not have shut-off valve on either side of the backflow prevention mechanism. Any backflow prevention assembly without the shut-off valves is called a device. Bypass means any arrangement of pipes, plumbing, or hoses designed to divert the flow around an installed device or assembly through which the flow normally passes. Certified assembly testing technician means a person certified by the state department of health as an assembly testing technician. Certified assembly repair person technician means a person certified by the state department of health as an assembly repairman technician. Cross-connection means any actual or potential connection between the public water system and a source of contamination or pollution. Cross-connection control means the use of backflow prevention assemblies, methods and procedures to prevent contamination or pollution of a potable water supply through cross-connections. Detector double check valve assembly (DDCVA) means a DCVA with an additional smaller DCVA assembly and flow detector meter in parallel, used to detect system leaks and unauthorized use. Detector reduced pressure zone assembly (DRPZA) means an RPZA with an additional smaller RPZA assembly and flow detector meter in parallel, used to detect system leaks and unauthorized use. Double check valve assembly (DCVA) means a backflow prevention assembly consisting of two independently operating check valves, four test cocks, and two shut-off valves. Hazard means any contaminant or pollutant which if it enters the potable water system causes a risk to public health or has an adverse effect on the public potable water system. Industrial fluid means a fluid or solution which may be chemically, biologically or otherwise constituted so as to constitute a health hazard or to cause an adverse effect if introduced into the public water system. Inspector means a person authorized by the approving authority to perform inspections of user's facilities for the purpose to determining compliance with the city cross-connection program. Permit means a document issued by the city which allows the use of a backflow prevention assembly at the user's service connection. Person means any individual, partnership, company, public or private corporation, political subdivision or agency of the United States or any other legal entity. Potable water means any water which, according to recognized standards, is safe for human consumption. Program means the city cross-connection program. Public water supply means the network of piping, appurtenances, pumps, storage and treatment facilities owned, operated or controlled by the city for the purpose of conveying, treating or controlling the delivery of potable water. Reduced pressure zone assembly (RPZA) means the backflow prevention assembly consisting of four test cocks, two shut-off valves, two independently operating, spring loaded check valves with a reduced pressure zone between the checks. The zone contains a relief port which will open at atmosphere if the pressure in the zone falls within two psi of the supply pressure. The assembly provides protection against both backpressure and backsiphonage. Retrofit means the replacement of an existing device or backflow prevention assembly with an approved backflow prevention assembly. Service connection means the piping connection between the public water system and a user's system. Thermal expansion means the condition which causes water, by its being heated, to expand its volume and backflow into the public water system to dissipate the increasing pressure created by said expansion. User means that person, whether an owner, tenant or otherwise possessing an interest in the subject property, who makes the arrangement with the city for water service to the subject property, and any contract user, which includes all persons and entities who purchase water from the city, whether on a full-time or an emergency basis, for individual use, resale and/or redistribution outside the corporate limits of the city. The provisions of this division shall apply to all affected users who are those users who use the water service for a commercial, industrial, or governmental (as classified by type of utility account) activity and all contract users who purchase water for resale or redistribution.
(Code 1992, § 25-167; Ord. No. 50-01, § 2, 8-22-2001)
Ask a question about Fort Smith law
Corpus searches the Fort Smith sections it holds and shows the ones that match, with their citations. Free, no sign-in.
