Sec. 25-168. - Requirements.

(a) All affected users of the city's water system shall adhere to the provisions of the program. All affected users shall: (1) Eliminate all cross-connections or install an approved backflow prevention assembly, at a location acceptable to the approving authority, after the service connection and prior to the first branch or connection to the user's system. (2) Retrofit unapproved existing backflow preventer that: a. Cannot be made testable; b. Are relocated; c. Require repair parts costing more than $50.00; d. That do not meet the test standards as established by the state department of health; or e. When the approving authority determines the operation or maintenance of the device/assembly constitutes such a potential hazard as to require retrofitting within a specified time. (3) Correct malfunctions of backflow prevention devices or assemblies. (4) Inform the approving authority of any existing, proposed or modified cross-connection. (5) Not install a bypass around any backflow prevention assembly unless there is an approved backflow prevention assembly in the bypass. (6) Ensure the type of backflow prevention assembly and manner of installation, existing and proposed is approved by the approving authority. (7) Inform the approving authority of any auxiliary water supply on or available to the subject property. (8) Inform the approving authority of any plumbing installed prior to the inlet side of the backflow prevention assembly. (9) Pay all fees for permits, inspections, and testing. (10) Have any backflow prevention device and backflow prevention assembly tested by a certified assembly testing technician at least once a year. In those instances where the approving authority deems necessary, inspections and testing may be required at more frequent intervals. The user shall cause the certified assembly testing technician to provide to the approving authority a copy of the certified test and inspection, on a form approved by the approving authority, within three working days after the completion of the test and inspection. (11) Where a backflow prevention assembly is required by this division, install two backflow prevention assemblies in parallel if uninterrupted water service is desired during testing or repair. (12) Upon verification from the approving authority that a requirement for the installation of a backflow prevention assembly exists, submit, within a reasonable time specified by the approving authority, installation plans for review and approval; and upon approval, install an approved backflow prevention assembly. Plan submission shall include detailed information as required by the approving authority. After approval of installation plans, the approving authority will issue a construction permit for installation of the backflow prevention assembly. When the installation of the backflow prevention assembly has passed a final inspection, an assembly permit will be issued by the approving authority. (13) Unless installer is a certified tester who provides a testing report, have tested all newly installed backflow prevention assemblies within ten days of the final approved inspection date. Assembly permits shall not be issued without this satisfactory testing. (14) Obtain an assembly permit from the approving authority for all service connection backflow prevention assemblies or devices existing at the time of adoption of this division. An assembly permit authorizes the use of the backflow prevention assembly and is necessary for establishing or continuing water service. Assembly permits, whether issued pursuant to this section or subsection (a)(12) of this section, are issued for one year periods, but may be revoked if the user fails to comply with the provisions of this division. (15) Ensure only individuals licensed by the state as certified assembly repairman technicians accomplish repairs, installation and maintenance on backflow prevention assemblies. (16) Be responsible for installing any thermal expansion control or release device within user's plumbing system to control or release pressures that, prior to the installation of a backflow prevention assembly, may have dissipated into the public water system. (b) Any backflow prevention assembly which fails during a periodic test shall be repaired or replaced. When repairs are necessary, upon completion of the repair the assembly will be retested at user's expense to ensure correct operation. Other than water required for testing, water service will be discontinued until the assembly has been repaired or replaced and satisfactorily tested. (c) No water service connection shall be installed or maintained by the public water system unless the water supply is protected as required by state laws, regulations and this division. Service to any customer shall be discontinued by the public water system if a backflow prevention assembly required by the approving authority is not installed, tested and maintained; or if it is found that a backflow prevention assembly has been removed or bypassed; or if an unprotected cross-connection exists within the user's water system. (d) In the case of premises having an auxiliary water supply which is not, or may not be, of safe bacteriological or chemical quality and which is not acceptable as an additional source by the approving authority, the public water system shall be protected against backflow by installing an approved backflow prevention assembly in the service line, unless the user obtains a variance pursuant to section 25-174. (e) In cases where industrial fluids are handled in such a fashion as to create an actual or potential hazard to the public water system, the public water system shall be protected against backflow from the user by installing an approved backflow prevention assembly in the service line, unless the user obtains a variance pursuant to section 25-174. (f) In cases of intricate plumbing and piping arrangements, or where entry to all portions of the premises is not readily accessible for inspection purposes making it impracticable or impossible to ascertain whether or not cross-connections exist, the public water system shall be protected against backflow from the user's service connection by installing an approved backflow prevention assembly in the service connection, unless the user obtains a variance pursuant to section 25-174.

(Code 1992, § 25-168; Ord. No. 50-01, § 3, 8-22-2001)

Ask a question about Fort Smith law

Corpus searches the Fort Smith sections it holds and shows the ones that match, with their citations. Free, no sign-in.