§ 6 — Design Standards for New Construction and Alterations to Non-Historic Structures
Municipal Code of the City of Fort Smith, Arkansas (Codified through Ordinance No. 126-24, enacted December 3, 2024. (Supp. No. 4)) · Fort Smith Municipal Code § 6
Corpus is an independent public-information project, not the official City of Fort Smith website. Stable reference: corpuslaw.us/code/20323755-545e-4cd5-9b75-4382a0f3d60c
Section 6. - Design Standards for New Construction and Alterations to Non-Historic Structures
6.1 Applicability. The Design Standards for the DT FBC District shall establish a coherent urban environment, protect the historic character and encourage enduring, attractive and sustainable development. Development plans shall be reviewed by the Director or designee for compliance with the standards below. 6.2 Intent. The key design principles establish essential goals for development in the DT FBC Area to ensure the preservation, sustainability and visual quality of this unique environment. Buildings shall be located and designed so that they provide visual interest and create enjoyable, human-scaled spaces. The key design principles are: 6.2.1 New buildings shall utilize building elements and details to achieve a pedestrian-oriented public realm with transitions into human-scale private places, and connectivity to adjacent neighborhoods; 6.2.2 Compatibility is not meant to be achieved through uniformity, but through the use of variations in building elements to achieve individual building identity; 6.2.3 Building façades shall include appropriate architectural details and be ornamental in such a way that creates variety and interest; and 6.2.4 Open space(s) shall be incorporated to provide public areas integral to the urban environment. 6.3 Building Orientation 6.3.1 Buildings shall be oriented towards the highest priority classified street. 6.3.2 When a property has frontage along two identically classified streets (two Type A, two Type B, or two General Street classification), the primary frontage shall be the street that has the highest calculated existing façade buildout and/or the least percentage of surface parking along the street frontage of all the adjoining blocks of the subject property. When a clear primary frontage cannot be determined by evaluating the adjacent block façade buildout, then the applicant can choose either street as the primary street. 6.3.3 The primary entrance to buildings shall be located on the street along which the building is oriented. At intersections, corner buildings may have their primary entrances oriented at an angle to the intersection. 6.3.4 All primary entrances shall be oriented to the public sidewalk or within a forecourt adjacent to a public sidewalk for ease of pedestrian access. Secondary and service entrances may be located from internal parking areas or alleys. 6.3.5 Where a building is set back at the ground floor along a Type A Frontage, the setback area shall be paved flush with the sidewalk up to the front entrance. [image omitted; see the official code] Illustration Depicting the Required Building Orientation and Primary Entrance 6.4 Design of Parking and Service Areas 6.4.1 Any surface parking in the setback area with frontage along all streets (except alleys) shall be defined by a minimum 3-foot high Street Screen. Required Street Screens shall be of one of the following: a. The same building material as the principal structure on the lot or b. A vegetative screen composed of shrubs planted to be opaque at maturity, or c. A combination of the two. [image omitted; see the official code] Illustration of Required Street Screen 6.4.2 Species shall be planted per best practices and based on urban tree species or applicable planting species from the list in Section 27-602-3 of the UDO. 6.4.3 The required Street Screen shall be located between the ROW and the minimum setback frontage. 6.4.4 Street Screens cannot block any required sight triangles along a cross street or driveway. 6.4.5 Street Screens may include breaks to provide pedestrian access from any surface parking or service area to the public sidewalk. 6.5 Design of Parking Structures. 6.5.1 All frontages of parking structures located on Type A frontage shall not have parking uses on the ground floor to a minimum depth of 30 feet along that frontage. 6.5.2 The amount of Type A frontage devoted to a parking structure shall be minimized by placing the shortest dimension(s) along the Type A frontage. 6.5.3 Parking structure façades on all Type A Frontage shall be designed with both vertical and horizontal articulation. 6.5.4 Where above ground structured parking is located at the perimeter of a building with frontage along a Type A Frontage, it shall be screened in such a way that cars on all parking levels are screened from view of the Type A Frontage. Architectural screens shall be used to articulate the façade, hide vehicles and shield lighting. 6.5.5 Parking structures and adjacent sidewalks shall be designed so pedestrians are clearly visible to entering and exiting automobiles. [image omitted; see the official code] Images showing Parking Garage Design Examples 6.6 Driveways, Alleys and Service Access. 6.6.1 Unless otherwise specified in the Character Area standards, driveways and off-street loading and unloading may be located along the lowest classified street or mutual access easement to an adjoining property with direct driveway access to any other street. Porte-cocheres entrances may be allowed for hospitality and entertainment uses along all streets as long as they are designed to ensure pedestrian safety and walkability. 6.6.2 Shared driveways, mutual access easements shall be required for adjoining properties when driveway and service access is off a Type A Frontage. 6.6.3 Service and loading/unloading areas shall be screened per standards in Section 6.7. 6.6.4 Unless required to meet minimum fire access or service access standards all commercial and mixed-use driveways/alleys shall be a minimum of 20 feet in width. Service driveways/alleys shall be a maximum of 32 feet in width garage to garage. Driveways wider than 24 feet in width shall only be located off Type B Frontages. Driveways/alleys along state roadways shall meet state standards or the City's adopted ordinances or design specifications. 6.7 Design of Automobile-Related Building Site Elements. 6.7.1 Drive-through lanes for commercial uses shall not be located on any Type A or primary street Frontage. Drive-through lanes shall be hidden behind a street screen along any non-primary street. 6.7.2 All off-street loading, unloading and trash pick-up areas shall be located along the lowest priority classified street or alleys unless permitted in the specific building form and development standards in Section 6. Any off-street loading, unloading or trash pick-up areas shall be screened using a street screen that is at least as tall as the trash containers and/or service equipment it is screening. The street screen shall be made up of: a. The same material as the principal building or; b. A living screen or; c. A combination of the two. 6.7.3 Design of Auto Service Bays: a. If permitted under Table 4.2 auto service bays for commercial uses shall not be located with frontage along any Type A Street. All views of auto service bays shall be hidden behind a three foot high street screen along both Type A and Type B frontages (see illustrations below). The street screen shall be made up of (i) the same material as the principal building or (ii) a living screen of (ii) a combination of the two; b. Any automobile service use of a site or property with Type A or B Frontage shall have a primary building entrance from a public sidewalk along its highest designated street frontage. 6.8 Mechanical and Service Screening. 6.8.1 All buildings shall be designed such that no mechanical equipment (HVAC, etc.) is visible from the public right-of-way or open space, whether the equipment is located on the ground, exterior walls or roof. 6.8.2 The screening material used shall be the same as the primary exterior building material used and raised at least one (1) foot above the top of the mechanical equipment. [image omitted; see the official code] Illustration of Mechanical Equipment Screening 6.9 Façade Composition. 6.9.1 Buildings shall maintain a façade rhythm of 20 feet to 30 feet along all Type A Frontages. 6.9.2 This rhythm shall be expressed by changing materials, or color, or by using design elements such as fenestration, columns and pilasters, integrated colors, or by varying the setback of portions of the façade. 6.9.3 Storefronts on façades that span multiple tenants shall use architecturally compatible materials, colors, details, awnings, signage and lighting fixtures. 6.9.4 Building entrances shall be defined and articulated by architectural elements such as lintels, pediments pilasters, columns, porticos, overhangs, railings, balustrades and others, as appropriate. All building elements shall be compatible with the architectural style, materials, colors and details of the building as a whole. Entrances to upper level uses shall be defined and integrated into the design. 6.9.5 Specific to Civic/Medical Area: a. Buildings under 10,000 sq.ft. shall meet the design standards in this section of the DT-FBC. b. Buildings over 10,000 sq.ft. shall either meet the design standards in this Section of the DT-FBC or UDO Section 27-602-Architectural Design of Structures. 6.9.6 Multi-Family buildings shall incorporate a minimum of four (4) of the following elements on each Type A or Type B façade: a. Balconies, a minimum of 25 square feet in area; b. Bay or box windows; c. Porches or covered entries; d. Dormers; e. Awnings or canopies; f. Structural offsets a minimum of four feet from the principal plane of the façade; g. Accent materials such as brick, stone, or stucco with banding highlights; h. Ornamental or decorative window grills and shutters; i. Vertical elements such as towers or building end-caps that demarcate building modules; j. Other comparable feature as approved by the Director. [image omitted; see the official code] Image showing a building with accent materials (stone and stucco with banding highlights) 6.10 Windows and Doors. 6.10.1 Windows and doors on street (except alleys) fronting façades shall be designed to be proportional and appropriate to the specific architectural style of the building. First floor windows shall not be opaque or mirrored glass. Tinted windows shall have a minimum visual transmittance of 0.6. [image omitted; see the official code] Images Showing Storefront Window Transparency 6.10.2 All ground floor front façades along Type A Frontages or Civic/Open Spaces shall have transparent storefront windows covering no less than 40% of the ground floor façade area. Each upper floor of the same building façades facing a Type A Frontage or Civic/Open Space shall contain windows covering at least 25% of the façade area. All other street facing façades (except alleys) shall have windows covering at least 15% of the façade area for all floors. 6.11 Building Materials. 6.11.1 Table 5.1 Development Standards shall establish the required minimum percentages of building materials permitted for each building façade based on the Character Area. 6.11.2 Table 6.1 shall establish the three categories of building materials with Primary and Accent materials permitted in each of the categories. These standards shall apply to all external building material with the exclusion of doors and windows. TABLE 6.1 BUILDING MATERIAL CATEGORIES Exterior Materials | Category 1 | Category 2 | Category 3 ■ = Permitted as Primary* □ = Permitted as Accent "blank cell" = Not Permitted as Either Masonry (natural stone, brick, rock, marble, or granite) or other historically used exterior materials | ■ | ■ | ■ Stucco using 3-step process | ■ | ■ | ■ Cast stone or synthetic stone or split face | □ | ■ | ■ Concrete masonry units, glass block, glass curtain wall, tilt wall | □ | □ | ■ Wood (siding or panels), board and batten | □ | ■ Residential only □ All other uses | ■ Residential only □ All other uses Metal | □ | ■ Fiber cement siding | □ | ■ Residential only □ All other uses | ■ Residential uses only □ All other uses Exterior Insulation and Finish System (EIFS) (upper floors only) | □ | □ Vinyl siding (for multifamily residential uses only) | □ | □ Other materials similar to the ones listed above | Permitted as Primary or Accent based on the Director's evaluation of how best the material fits into the above categories 6.12 Additions to Existing Buildings. 6.12.1 Relationship to Main Building. Additions to existing buildings should be compatible in size, scale, color, materials and character of the main building and its environment. 6.12.2 Original Design Character. Wherever possible, new additions or alterations to buildings should not obscure or confuse the essential form and character of the original building. Avoid new additions or alterations that would hinder the ability to interpret the design character of the historic period of the district. Alterations that seek to imply an earlier period than that of the building are inappropriate. Alterations that seek to imply an inaccurate variation on the historic style are also inappropriate. 6.12.3 Materials. Unless the original building façade materials are used for the building addition, standards in Section 6.11 shall apply.
(Ord. No. 121-21, § 2(att.), 12-2-2021; Ord. No. 53-22, § 1, 7-12-2022)
Ask a question about Fort Smith law
Corpus searches the Fort Smith sections it holds and shows the ones that match, with their citations. Free, no sign-in.
