§ 7 — Garrison Avenue Historic District Architectural and Design Standards
Municipal Code of the City of Fort Smith, Arkansas (Codified through Ordinance No. 126-24, enacted December 3, 2024. (Supp. No. 4)) · Fort Smith Municipal Code § 7
Corpus is an independent public-information project, not the official City of Fort Smith website. Stable reference: corpuslaw.us/code/777754bf-ce4b-4750-9fba-9caf3be60c02
Section 7. - Garrison Avenue Historic District Architectural and Design Standards
7.1 Applicability. This section applies to all contributing buildings and individually listed buildings in any local, state, or National Register in the Garrison Avenue Historic District (GAHD) boundary and also located in the Garrison Area, Cisterna Area, Civic/Medical Area or the Riverfront Area as identified in the FBC Boundary Map (Appendix A). Other buildings shall be regulated by the standards in Section 6 of this Code. Streetscape, parking design standards and any other urban design standard not covered in this section shall be regulated by Section 8 and Section 6 of this Code. All renovation and restoration projects shall be approved by the Director. Any projects that seek a variance to these design standards shall first consult the Director and if necessary, follow the variance process as described in the UDO 27-337. For reference, information on historic building design and style has been included in Appendix D. 7.2 Intent. The Architectural and Design Standards for the GAHD shall establish a coherent urban character, protect the historic character and encourage enduring, attractive and sustainable development. 7.3 It is the intent of this subsection to provide design standards that achieve the following: 7.3.1 To accommodate change in a manner that is compatible with the historic character of Garrison Avenue without imitating it. 7.3.2 To preserve and enhance the historic, architectural and cultural features of the GAHD area. 7.3.3 To protect the integrity of the historic district. 7.3.4 To protect the sense of time and place conveyed by the historic buildings as a collection. 7.3.5 To promote a sense of identity and consistency for the district. 7.3.6 To minimize negative impact on adjacent properties by inappropriate developments. 7.3.7 To preserve the integrity of each individual historic structure. 7.3.8 To preserve character-defining features. 7.3.9 To avoid alterations that would remove or obscure historic character. 7.3.10 To enhance the perception of the historic character of the historic structure. 7.3.11 To restore damaged historic features and reconstruct missing ones (where adequate documentation exists of what was there historically) and to remove non-contributing alterations. 7.3.12 To preserve and enhance the sense of time and place in the historic Garrison Avenue Commercial District. 7.4 Interpretation. The most significant elements taken into the design of new buildings will be the basic building volume, street alignment, and material uniformity. The importance of context, including the relationship of a proposed project to abutting buildings and side streets should be part of the design decisions for new buildings. The Garrison Avenue commercial district contains buildings that have evolved since the 1870s. Since characteristics differ within the district itself, particular attention to each block should be given in planning new structures. Emphasizing context and design elements, rather than styles, the broadest and most flexible interpretation for new construction is encouraged. 7.5 Design and Architectural Standards: 7.5.1 Accessibility. The Americans with Disabilities Act (ADA) mandates that places of public accommodation be accessible to all users. These standards should not prevent or inhibit compliance with accessibility laws. All new construction shall comply completely with ADA. Owners of historic properties also should comply to the fullest extent possible, while also preserving the integrity of the character-defining features of their buildings. For example, historic door thresholds often made of stone or cast metal should be preserved when feasible. Original archway widths should be preserved as well, where feasible. Special provisions for historical buildings exist in the laws that allow some alternative solutions in meeting the ADA standards. 7.5.2 Additions. Because most lots already have structures on them, any additions are likely to occur as roof-top, side, or rear additions. An addition shall be compatible in scale, materials, and character with the main building. Using similar material is appropriate. In some cases, a simpler, less noticeable material also may be appropriate. The materials shall be in proportion to the historic building. Materials, finish and details on any addition shall not call attention to the new space. See section on Additions to Existing Buildings, Section 7.6. 7.5.3 Traditional Façade & Storefront Design. a. The basic traditional commercial façade consists of three parts: the storefront with an entrance and large display windows, an upper masonry façade and a decorative cornice. The basic storefront design includes large windows with thin framing members, a storefront cornice, transom, bulkheads and often a recessed entrance. b. If planning improvements to a storefront, the original proportions shall be carefully considered and respected. On occasion, one business utilizes more than one historic storefront. The individual identities of the original buildings should be retained, and the use of awnings, colors and signage should be used to unify the storefronts, rather than removing original materials and creating one new, modern storefront out of several buildings. 7.5.4 Storefront Features. Existing historic storefronts date from the late 19th and early 20th centuries and are designs typical of commercial architecture of the period. Storefronts had five main characteristics: a. Lower panels or bulkhead: The large plate glass windows for the display of goods rested on lower panels called bulkheads. These were primarily rectangular in design, of frame or brick construction and often had raised patterns. b. Display windows: Merchants in the early 20th century relied on extensive window displays to advertise their goods. High visibility was a priority for these merchants and the installation of large sheets of plate glass provided maximum exposure of wares. c. Cast iron pilasters: To support the weight of the brick masonry above the storefront, cast iron columns or brick piers were often added. The cast iron was shaped into decorative forms that supported the load of the brick upper façade allowing large display areas. Brick piers were also used to support the weight of the upper façade brick. d. Large central or corner entrances: Many commercial buildings originally had large central or corner entrances of single or double doors. e. Transoms: Over the display windows and entrances were usually transom bars and transoms. Transoms allowed light into the building and were used for additional areas of signage and display. Transoms utilized clear, textured, leaded or stained glass. 7.5.5 Storefront Guidelines. a. Original storefronts or historic storefronts that date from the late 19 th and early 20 th centuries should not be altered but repaired and retained. b. Future storefront remodeling or renovation shall follow historic guidelines such as retaining historic features, reconstruction based on historic photos or illustrations, or renovation based on typical storefront designs of the period. c. All decorative metals or glass on historic storefronts shall be retained and maintained. d. If an original storefront has been removed, a new storefront design shall take the original proportions and materials into account. Modern materials are acceptable so long as they are in proportion to traditional design. Shiny, brushed aluminum is not appropriate. Original materials or aluminum with a baked enamel finish are more appropriate. e. A storefront should be composed almost entirely of clear glass. Tinted or reflective glass is in-appropriate. Should privacy be desired, interior window treatments or movable barriers should be considered. f. Transoms over doors or display areas should not be enclosed or painted out. g. Designs and materials such as sloping mansard roofs, metal siding, vertical siding, EIFS, wood shingles, imitation brick, imitation stone, vinyl and aluminum siding are not appropriate and should not be added to storefronts or upper stories. Stucco shall not be used over other masonry materials. h. Avoid concealing original façade materials. If original material is to be replaced, duplicate the element utilizing a material similar to the original material. Avoid the use of shiny, reflective materials such as mirror, glass and plastic panels as façade materials. New materials should be similar in texture and pattern to those found historically. i. Cast iron should be painted to prevent rust and corrosion. Rust or paint build-up may be re-moved by chemical treatment or low-pressure dry grit blasting (80-100 psi), taking care to protect any adjacent building materials that might be damaged. 7.5.6 Storefront Entries. Traditionally, entrance doors were made of wood with a large pane of glass. Standard aluminum and glass commercial doors have replaced many original doors. Aluminum can be made more compatible by being finished in or made of a dark color and by selecting a design in the proportions of the original. The rhythm of entries is important in the downtown area. Historic entry systems, whether recessed or flush with the public walk, shall be retained. 7.5.7 Storefront Entry Guidelines. a. Original entry doors should be retained and restored in their original location and configuration when appropriate. If modifications have been made, a new entry should be designed based upon the traditional design elements. b. Use doors with large areas of glass and a painted or baked enamel frame. c. Avoid unfinished bright aluminum or stainless-steel frames. d. Avoid residential style doors, including those from historic residences. e. Finished frames may be varnished or painted wood or metal with anodized or painted finish. Wider metal frames are generally encouraged over narrow frames. 7.5.8 Storefront Windows. For most downtown buildings, large windowpanes at the first-floor level are advisable for both retail and office use. Avoid multi-pane designs that divide the storefront window into small components. This look is not typical of most downtown buildings, and is therefore inappropriate. Tinted glass shall have a minimum visible transmittance of 0.6 and is generally accepted in decorative transoms. Awnings and interior window treatments can protect from the sun, but allow its warmth to enter in colder seasons while retaining the traditional appearance. 7.5.9 Storefront Window Guidelines a. Original storefront window configuration should be maintained. b. Tinted and/or reflective glass is inappropriate. c. Avoid multi-pane designs. d. Preserve existing transoms. Leaded and prismatic decorative transoms should be preserved in place. For other transoms, clear glass is generally preferable. e. Use the transom as a place for a sign or decorative plane if the use of glass is not feasible, but retain the original proportions of the opening. 7.5.10 Bulkhead Guidelines a. Existing storefront bulkheads should be retained and repaired as needed. If bulkheads have been removed, appropriate bulkheads should be installed, based upon the historic elements. b. If the original design is missing, use historic documentation to duplicate an appropriate design. If original information is not available, develop a new simplified design that retains the original character. c. For renovations where there is no physical or documentary evidence, appropriate bulkhead materials are painted wood, brick, stone or painted metal. Plywood may also be acceptable when no original material exists. Artificial siding, plywood and EIFS shall not be appropriate if replacing original material. 7.5.11 Awnings & Canopies a. The canvas awning or horizontal, fixed canopy was an important design element in the traditional storefront. It provided cover, added color and served as a transition between the storefront and the upper façade. Most buildings that face the sun had awnings. Look at old pictures of your building to see how awnings were used. b. For canopies, appropriate supporting mechanisms shall be wall-mounted brackets, chains and posts. Wall-supported canopies also may be considered for new construction. c. Fabric awnings are appropriate and encouraged for historic buildings and new construction. d. Operable awnings also may be considered. e. Rigid frame awnings also may be considered. f. Rigid canopies are encouraged to provide recessed lights and illuminate the sidewalk. g. Use colors that are compatible with the overall color scheme of the façade. Solid colors or simple muted striped patterns are appropriate. h. Simple shed shapes are appropriate for rectangular openings. Semi-circle shapes are appropriate for arches. Odd shaped awnings are inappropriate. i. Awnings and canopies should be mounted to accentuate character-defining features. They should be mounted to highlight moldings that may be found above the storefront. Their mounting should not damage significant features and historic details. An awning can be attached above the display windows and below the cornice sign panel. Sometimes it is mounted between the transom and the display windows, allowing light into the store while shading the merchandise and pedestrians from the sun. j. When awnings are used on buildings, canopies shall be in good condition and comply with the City of Fort Smith's Property Maintenance Code. Colors of canopies shall be approved by the Director or designee. If a change of ownership occurs with the business occupying the space and a canopy is used for identification of the business the current business shall be identified on the canopy or modified to remove the old business name and left blank. k. A standard street-level awning should be mounted so that the valance is about 7 feet above the sidewalk and projects out between 4 and 7 feet from the building. A 12-inch valance flap is usually attached at the awning bar and can serve as a sign panel. l. An awning should reinforce the frame of the storefront and should not cover the piers or the space between the second-story window sills and the storefront cornice. m. Inappropriate storefront alterations can be effectively disguised by mounting an awning over the alterations while maintaining the proportions of a traditional storefront. n. Aluminum awnings or canopies generally detract from the historic character and should not be erected. If a flat canopy exists, it can be dressed up with a 12-to 24-inch awning valance. o. Various awning materials offer different colors and patterns. There are several to choose from: canvas, vinyl coated canvas and acrilan, a synthetic material. Each varies in cost and relative durability. 7.5.12 Brick and Masonry a. Materials original to the building shall be preserved. b. Brick and masonry shall never be sandblasted or subjected to any kind of abrasive cleaning. Do not clean with high pressure water which exceeds 450 pounds per square inch. These processes damage brick surfaces and erode mortar joints. c. To avoid needlessly introducing moisture or chemicals into the building, brick and masonry should be cleaned only when necessary to remove heavy soiling and to stop deterioration. d. Paint removal should not be done if the paint is firmly adhered to and therefore protecting the masonry surface. e. Water-repellent coating should not be added unless masonry repairs have failed to stop water penetration problems. f. As a general rule, brick and masonry shall not be painted unless in the case of brick, if the brick is extremely mismatched from earlier alterations or cannot withstand weather. g. Brick and masonry shall not be covered with Exterior Insulation Finish System (EIFS), stucco or any similar material. h. Repointing shall match original width, depth, color, raking profile, composition and texture. i. Repoint should never be done with Portland cement or other hard mortar but with original compounds, if it can be determined, or with a historic compound such as one-part lime and two parts sand. Original type mortar compounds allows for expansion and contraction while hard mortar or cement prevents the expansion and contraction process. 7.5.13 Codes. All standard construction projects shall comply with the City of Fort Smith, Arkansas building, fire, plumbing, mechanical, property maintenance, and electrical codes in the most recent adopted edition. 7.5.14 Color. Use colors to create a coordinated color scheme for the building. The façade should "read" as a single composition. a. Base or background colors should be muted. Use the natural colors of the building materials, such as the buff color of limestone, as the base for developing the overall color scheme. b. Matte finishes are preferred to high glossy ones. c. Reserve the use of bright colors for accents only. Bright colors may highlight entries, for instance. d. Using the historic color scheme of the building is preferred. When historic colors are to be used, provide evidence of their historic application. Brickwork was usually unpainted. 7.5.15 Cornices a. Most historic commercial buildings have cornices to cap their façades. Their repetition along the street continues to the visual continuity on the block. They may be a straight or stepped parapet. b. Cornice that is intact shall be preserved. Reconstruct a missing cornice when historic evidence of its character is available. Use historic photographs, if available, to determine design details of the original cornice. c. Substitution of another old cornice for the original may be considered, provided that the substitute is similar to the original. d. If it is not possible to find photographs or evidence of the original cornice, a simplified interpretation is appropriate. Materials for reconstructed cornices include stone, brick and stamped metal. 7.5.16 Fences and Walls. Fences and/or walls are not likely to have existed historically in the Garrison Avenue commercial district. If historic documentation of fences or walls exist, it may be appropriate to reconstruct a similar type fence or wall. All fencing shall be approved by the Director. 7.5.17 Entries a. Maintain existing recessed entries. The repetition of recessed entries provides a rhythm of shadows along the street, which helps establish a sense of scale. These recessed entries were designed to provide protection from the weather, and the repeated rhythm of these shaded areas along the street helps to identify business entrances. b. The original doorway should be preserved on all historic buildings. Some may be double-leaf, panel doors with glass in the upper one-half. Doors with metal frames and large areas of glass are appropriate on Art Deco and Art Modern style buildings. c. If the original door design is unknown, replace with a single light (glass area) door design, not solid paneled door, decorative doors, or any kind of door based upon a different historical period or style. d. Preserve, maintain, or repair original display windows. If a storefront is missing display windows, new windows should match the original in location, design, size, and materials. Glass used in windows shall appear similar to that used historically. Transparent, clear glass is appropriate. Opaque and mirrored glass shall be prohibited and tinted glass shall have visual transmittance 0.6 or higher. Retaining extant historic glass is important and should be encouraged in all cases except where safety glass or wire glass is required by code. 7.5.18 Kickplates a. The kickplate, or bulkhead, located below the display window, adds interesting detail to the streetscape and should be preserved. b. If the original kick plate is missing, develop a compatible replacement design. Wood and masonry are appropriate materials for replacements. c. Coordinate the color of the kickplate with other trim elements on the buildings. 7.5.19 Entry Way Name Plates. Some of the buildings within the GAHD have name plates generally made out of tile or granite that give recognition to the original or previous owner. These shall be preserved when possible. 7.5.20 Landscaping. Shall meet the standards in Section 6.5. 7.5.21 Building Lighting a. Lighting designs should enhance the ability to interpret the historic character of the street, as seen at night, and should not overwhelm it. b. Use lighting to: i. Accent architectural details ii. Accent building entries iii. Accent signs iv. Illuminate sidewalks c. All light sources shall be shielded. Lighting should not dominate a façade or the street. Washing the entire façade of a building with light is inappropriate. Lights focused upward to light the façade also are inappropriate. d. Permanent animated lighting (such as chase lights) is prohibited. 7.5.22 Mechanical Equipment & Utilities. Shall meet the standards in Section 6. 7.5.23 Parking. Shall meet the standards for parking setbacks in Section 5, parking lot screening in Section 6 and Section 8. 7.5.24 Roofs a. Preserve the historic character of the building's roof line. b. Altering an existing historic parapet line is inappropriate. c. Set any new roof terraces back from the building front. 7.5.25 Walls a. Preserve original façade materials. Historically, brick and limestone have been the dominant building materials in the Garrison Avenue historic district. Historic building materials and the craftsmanship they exhibit add textural qualities, as well as visual continuity and character to the streetscape. b. When replacement of façade wall materials is necessary, the new materials should match the original in scale, color, texture and finish. c. Do not cover or obscure original façade materials. Covering of an original façade not only conceals interesting details, but also interrupts the visual continuity along the street. If the original material has been covered, uncover it, if feasible. d. Do not use harsh cleaning methods that could damage the finish of historic materials. Sandblasting, for example, is prohibited. e. Saving deteriorated parts which shall be replaced may later assist in matching reconstructed features. Wood sash windows, cornices and doors can often be restored or duplicated. 7.5.26 Windows & Doors a. Maintain historically significant storefront openings. The size and shape of original doors and windows are important characteristics that contribute to the integrity of historic commercial buildings. Avoid altering the shape of these features. b. Retain the original shape of the transom glass in historic storefronts. The upper glass band of traditional storefronts introduced light into the depths of the building, saving on lighting costs. These bands are found on many historic storefronts, and they often align at the same height. The shape of the transom is important to the proportion of the store front, and it should be preserved in its historic configuration. If the original glass is missing, installing new glass is preferred. How-ever, if the transom shall be blocked out, use it as a sign panel or a decorative band, but retain the original proportions. c. Preserve historic upper story windows. Historically, upper story windows had a vertical emphasis. The proportions of these windows contribute to the character of each commercial storefront. Do not block windows or alter their size. Consider re-opening windows that are currently blocked. Replace missing glass. Maintain the historic window sash when possible. 7.5.27 Rehabilitation to Existing Historic Building Standards. The standards that follow were originally published in 1977 and revised in 1990 as part of Department of the Interior regulations (36CFR Part 67, Historic Preservation Certifications). They pertain to historic buildings of all materials, construction types, sizes and occupancy and encompass the exterior and the interior of historic buildings. The Standards are to be applied to specific rehabilitation projects in a reasonable manner, taking into consideration economic and technical feasibility. a. A property shall be used for its historic purpose or be placed in a new use that requires minimal change to the defining characteristics of the building and its site and environment. b. The historic character of a property shall be retained and preserved. The removal of historic materials or alteration of features and spaces that characterize a property shall be avoided. c. Each property shall be recognized as a physical record of its time, place and use. Changes that create a false sense of historical development, such as adding conjectural features or architectural elements from another building, shall not be undertaken. d. Most properties change over time; those changes that have acquired historic significance in their own right shall be retained and preserved. e. Distinctive features, finishes, and construction techniques or examples of craftsmanship that characterize a property shall be preserved. f. Deteriorated historic features shall be repaired rather than replaced. Where the severity of deterioration requires replacement of a distinctive feature, the new feature shall match the old in design, color texture, and other visual qualities and, where possible, materials. Replacement of missing features shall be substantiated by documentary, physical, or pictorial evidence. g. Chemical or physical treatments, such as sandblasting, that cause damage to historic materials shall not be used. The surface cleaning of structures, if appropriate, shall be undertaken in the gentlest means possible. h. Significant archaeological resources affected by a project shall be protected and preserved. If such resources shall be disturbed, mitigation measures shall be undertaken. i. New additions, exterior alterations, or related new construction shall not destroy historic materials that characterize the property. The new work shall be differentiated from the old and shall be compatible with the massing, size, and architectural features to protect the historic integrity of the property and its environment. j. New additions and adjacent or related new construction shall be undertaken in such a manner that if removed in the future, the essential form and integrity of the historic property and its environment would be unimpaired. 7.6 Additions to Existing Historic Buildings. 7.6.1 Relationship to Main Building. Additions to existing buildings should be compatible in size, scale, color, materials and character of the main building and its environment. 7.6.2 Original Design Character. Wherever possible, new additions or alterations to buildings should not obscure or confuse the essential form and character of the original building. Avoid new additions or alterations that would hinder the ability to interpret the design character of the historic period of the district. Alterations that seek to imply an earlier period than that of the building are inappropriate. Alterations that seek to imply an inaccurate variation on the historic style are also inappropriate. 7.6.3 Location. When locating additions to historic buildings, maintain the pattern created by the repetition of building fronts in the area. Avoid impacts to special moldings, or decorative windows. 7.6.4 Materials. Shall meet standards in Section 6. 7.6.5 All other standards shall meet Section 5, 6, and 9 of this Code. 7.7 Demolition. 7.7.1 The demolition of an original feature or part of a historic building should be avoided whenever possible. 7.7.2 Any demolition request for a Contributing Structure to the Garrison Avenue Historic District shall be approved by both the CBID Commission and the Director after consideration of the provisions of this section. 7.7.3 Demolition of a building which contributes to the historic or architectural integrity of the historic district shall not occur, unless one or more of the following conditions are met: a. Public safety and welfare requires the removal of a building or structure as determined by the building or code inspector along with concurring reports commissioned by and acceptable to the Fort Smith Planning Department from a structural engineer or architect. b. Where economic hardship (the fact that no reasonable return on or use of the building exists) has been demonstrated and proven. c. Where rehabilitation is undesirable due to severe structural instability or deterioration of a building. d. The building has lost its original architectural integrity and no longer contributes to the district. e. No other reasonable alternative is feasible, including relocation of the building.
Ask a question about Fort Smith law
Corpus searches the Fort Smith sections it holds and shows the ones that match, with their citations. Free, no sign-in.
