Sec. 30-176. - Subdrain tile.

The owner's engineer shall determine areas where subdrain tile will be required. All trench excavation for the installation of subdrain tile shall be carried to the depth and width deemed necessary by the owner's engineer. Trenches shall be inspected and approved by the engineer prior to placing any filter stone or subdrain tile. The uniform layer of filter stone at least four (4) inches deep shall be placed in the bottom of the approved trench prior to installing subdrain tile. The subdrain tile shall be laid to the lines and grades established by the engineer. The joints between successive tiles shall be opened approximately one-fourth inch, and the upper half of the joint shall be covered with building felt or other approved material. The tile shall then be covered with filter stone to the required elevation.

(Code 1961, § 36-16(B)(4))