§ 8-562 — Duct testing (heating and air)

The Little Rock City Code, Revised 1988 (Supp. No. 83: codified through Ordinance No. 22,703, enacted December 16, 2025) · Little Rock City Code § 8-562

Corpus is an independent public-information project, not the official City of Little Rock website. Stable reference: corpuslaw.us/code/6730b532-8d8f-4b0a-bc70-38e475c9fb65

Sec. 8-562. - Duct testing (heating and air).

(a) New residential construction. Duct testing shall be required for all new single-family residential structures. Single-family residential developments that utilize the exact same floor plan multiple times are required to have duct testing completed on a minimum of twenty (20) percent of new single-family residential units. (b) New multi-family construction. Duct testing shall be required for all new multi-family developments and shall meet the following testing criteria when these developments utilize the exact same floor plan. (1) Two (2) units up to two hundred (200) units shall have a minimum of twenty (20) percent of units tested and certified. This includes individual floors with two hundred (200) units or less per floor. This includes individual buildings where the total number of units are less than two hundred (200) units for the entire building. (2) Two hundred one (201) units and up shall have a minimum of ten (10) percent of units tested and certified. This includes individual floors that exceed two hundred one (201) units or more per floor. This includes individual buildings where the total number of units exceed two hundred one (201) units or more. (3) In cases where the development is a continuous building completely connected, the number of units shall be determined where required fire tenant separation walls are installed. (4) If the development utilizes the same HVACR contractor for the duration of construction the rules for testing ten (10) percent or twenty (20) percent shall be granted. In cases where another HVACR Contractor is hired prior to completion of the project, the project regardless of the number of units shall meet the twenty (20) percent testing criteria up to completion. (c) Addition, alterations and renovations. Additions, alterations and renovations to existing residential structures shall not be required to comply with the duct testing requirements, but shall be required to comply with the 2014 Sr. Energy Code and 2010 AR Mechanical Code duct sealing requirements. (d) Repairs. All repairs to existing residential structures and mechanical systems shall not be required to comply with the duct testing requirements, but shall be required to comply with the 2014 AR Energy Code and 2010 AR Mechanical Code duct sealing requirements. (e) Duct tester qualifications. The duct tester shall be certified by one (1) of the following: (1) Residential Energy Services Network certified rater (RSNET) or equivalent. (2) Building Performance Institute certified rater (BPI). (3) AR HVACR Association certified duct tester.

(Ord. No. 21,577, § 1, 4-3-18)

Ask a question about Little Rock law

Corpus searches the Little Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.