15.12.010 - International Building Code—Adopted—Amendments.
A. The 2018 Edition of the International Building Code, copyrighted by International Code Council, Inc., shall be adopted including Appendix E, Appendix I, Appendix J, and Appendix K except as revised as follows: Section 101.1 Title. These regulations shall be known as the Building Code of The City of Bullhead City, hereinafter referred to as "this code." Section 105.2 Work exempt from permit. Buildings: (Remain—items 3, 5, 7, 8, 10 through 13) 1. One-story detached accessory structures, used as tool and storage sheds, gazebos, playhouses and similar uses, provided the floor area does not exceed 120 square feet (11.15 m 2 ) and contains no electrical, mechanical or plumbing systems. 2. Fences not over 6 feet (1829 mm) in height located outside of the Zoning setback areas. 4. Retaining walls that are located outside of the Zoning setback areas when not over 4 feet (1219 mm) in height measured from the bottom of the footing to the top of the wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids. 6. Sidewalks and driveways not more than 30 inches (762 mm) above adjacent grade, and not over any basement or story below and are not part of an accessible route. (Does not include portions within the City right-of-way.) 9. Prefabricated swimming pools accessory to a Group R-3 occupancy that contain water less than 18 inches (458 mm) in depth and are less than 8 feet (2438 mm) in width at any point, whether below ground or above ground. (Reference A.R.S. § 36-681) Section 107.1 General. (Add) Section 107.1.1 Documents prepared by a registered design professional. Not less than one set shall bear an original seal and signature of the registered design professional. An electronic signature, as an option to a permanently legible signature, in accordance with AZ Board of Technical Registration R4-30-304(G), is acceptable for all professional documents. Section 109.2 Schedule of permit fees. On buildings, structures, electrical, gas, mechanical, and plumbing systems or alterations requiring a permit, a fee for each permit shall be paid as required, in accordance with the most current City of Bullhead City Comprehensive Fee Schedule. Section 109.6 Refunds. The Building Official may authorize refunding of: 1. The full amount of any fee paid hereunder that was erroneously paid or collected. 2. Not more than fifty percent of the permit fee paid when no work has been done under a permit issued in accordance with this code. 3. Not more than fifty percent of the plan review fee paid when an application for a permit for which a plan review fee has been paid is withdrawn or canceled before any plan review is done. 4. Not authorize refunding of any fee paid except on written application filed by the original permittee not later than 180 days after the date of payment. Section 110.3.8 Energy efficiency inspections. Inspections shall be made to determine compliance with the approved plans. Section 502.1 Address identification. (Add) Section 502.1.1 Address identification for commercial buildings and multi-family dwelling buildings. Each character shall be a minimum of 6 inches (102 mm) high with a minimum stroke width of ½ inch (12.7 mm). (Add) Section 502.1.2 Address identification locations. Numbers are to be on the building and by another approved means if the building can not be seen from the public way. Section 903.2.8.1 Group R-3. An automatic residential fire sprinkler system may be installed in one- and two-family dwellings. An automatic sprinkler system installed in accordance with Section 903.3.1.3 shall be permitted in Group R-3 occupancies. (Reference A.R.S. § 9-807) Section 906.1 Where required. Exceptions: 1. In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in list items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 3-A:10-B:C. Section 1102.1 Design. Buildings and facilities shall be designed and constructed to the most restrictive provisions of this chapter, ICC A117.1 or Title 41, Chapter 9, Article 8, of the Arizona Revised Statutes (Arizonans with Disabilities Act). Section 1202.1 General. Buildings shall be provided with natural ventilation in accordance with Section 1202.5, or mechanical ventilation in accordance with the International Mechanical Code. Where the air infiltration rate in a dwelling unit is less than 5 air changes per hour where tested with a blower door at a pressure 0.2 inch w.c. (50 Pa) in accordance with Section R402.4.1.2 of the International Energy Conservation Code—Residential Provisions, the dwelling unit may be ventilated by mechanical means in accordance with Section 403 of the International Mechanical Code. Ambulatory care facilities and Group I-2 occupancies shall be ventilated by mechanical means in accordance with Section 407 of the International Mechanical Code. Section 1301.1.1 Criteria. All occupancy classifications may be designed and constructed in accordance with the 2018 International Energy Conservation Code. Buildings classified as an "R" occupancy shall be designed and constructed in accordance with the 2018 International Energy Conservation Code residential provisions or Chapter 11 of the 2018 International Residential Code for One- and Two-Family Dwellings, as amended in the City code. Figure 1608.2 Ground Snow Loads: (Add) Declared value 0. Figure 1609.3(1) Basic Design Wind Speeds, V, For Risk Category II Buildings and Other Structures: (Add) Declared value 100 mph. Figure 1609.3(2) Basic Design Wind Speeds, V, For Risk Category III Buildings and Other Structures: (Add) Declared value 105 mph. Figure 1609.3(3) Basic Design Wind Speeds, V, For Risk Category IV Buildings and Other Structures: (Add) Declared value 110 mph. Figure 1609.3(4) Basic Design Wind Speeds, V, For Risk Category I Buildings and Other Structures: (Add) Declared value 95 mph. Figure 1611.1 100-Year, 1-Hour Rainfall (inches) Western United States: (Add) Declared value 2 inches (50.8 mm) per hour. Section 1612.3 Establishment of flood hazard areas. To establish flood hazard areas, the governing body shall adopt a flood hazard map and supporting data. The flood hazard map shall include, at a minimum, areas of special flood hazard as identified by the Federal Emergency Management Agency in an engineering report entitled "The Flood Insurance Study of The City of Bullhead City," dated as the most current map available, as amended or revised with the accompanying Flood Insurance Rate Map (FIRM) and Flood Boundary and Floodway Map (FBFM) and related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section along with Chapter 15.36 Floodplain Regulations of the City code. 1613.1 Scope: (Add) Seismic Design Category declared value B (Reference 2018 IRC, Figure R301.2(2)). Section J102 Definitions. (Add) ENGINEERED GRADING. Grading quantities of 3,000 cubic yards or more. Plans shall be prepared by a qualified, licensed Arizona registrant. (Add) REGULAR GRADING. Grading quantities less than 3,000 cubic yards unless the Building Official determines that special conditions or unusual hazards exist, in which case grading shall conform to the requirements for engineered grading. Section J103.2 Exemptions. A grading permit shall not be required for the following: (Remain—items 2 through 7 and Exemption) 1. Grading less than 50 cubic yards and less than 12 inches of fill in a self-contained area, provided there is no danger to the public, and that such grading will not adversely affect adjoining properties. Section J104.1 Submittal requirements. In addition to the provisions of Section 105.3, the applicant shall state the estimated quantities of excavation and fill. The project is to meet the requirements of Chapter 15.40 Grading and Dust Control of the City code.
(Ord. No. 2024-09, § 1, 4-16-2024; Ord. No. 2011-16, § 2, 10-18-2011; Ord. 2008-16, § 1; Ord. 2006-58, §§ 3, 4; Ord. 2005-45, § 4)
Ask a question about Bullhead City law
Corpus searches the Bullhead City sections it holds and shows the ones that match, with their citations. Free, no sign-in.