For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.14.010 — International Residential Code

Municipal Code of the City of Bullhead City, Arizona (Codified through Ordinance No. 2026-14, enacted August 17, 2026. (Supp. No. 75)) · Bullhead City Municipal Code § 15.14.010

Corpus is an independent public-information project, not the official City of Bullhead City website. Stable reference: corpuslaw.us/code/d2295e37-af52-46bc-bf3f-f5535070248e

15.14.010 - International Residential Code.

A. The 2018 Edition of the International Residential Code, copyrighted by International Code Council, Inc., shall be adopted including Appendix A, Appendix B, Appendix C, Appendix G, Appendix H, Appendix J, Appendix K, Appendix M, Appendix N, Appendix O and Appendix P, except as revised as follows: Section R101.1 Title. These regulations shall be known as the Residential Code for One- and Two-family Dwellings of The City of Bullhead City and shall be cited as such and will be referred to herein as "this code." Section R105.2 Work exempt from permit. Building: (Remain—items 4, 6, 8 and 9) 1. One-story detached accessory structures, used as tool and storage sheds, gazebos, playhouses and similar uses, provided the floor area does not exceed 120 square feet (11.15 m 2 ) and contains no electrical, mechanical or plumbing systems. 2. Fences not over 6 feet (1829 mm) in height located outside of the Zoning setback areas 3. Retaining walls that are located outside of the Zoning setback areas when not over 4 feet (1219 mm) in height measured from the bottom of the footing to the top of the wall, unless supporting a surcharge. 5. Sidewalks and driveways. (Does not include portions within the City right-of-way.) 7. Prefabricated swimming pools that contain water less than 18 inches (458 mm) in depth and are less than 8 feet (2438 mm) in width at any point, whether below ground or above ground. (Reference A.R.S. § 36-681) 10. Decks that are not more than 30 inches (762 mm) above grade at any point 36 inches (914 mm) horizontal from the outside edge of the deck, are self-supporting and are not supporting a roof. Section R106.1 Submittal documents. (Add) Documents prepared by a registered design professional. Not less than one set shall bear an original seal and signature of the registered design professional. An electronic signature, as an option to a permanently legible signature, in accordance with AZ Board of Technical Registration R4-30-304(G), is acceptable for all professional documents. Section R108.2 Schedule of permit fees. The fee policy is established in City Chapter 15.12.010, Section 109.2 Schedule of permit fees. Section R108.5 Refunds. The refund policy is established in City Chapter 15.12.010, Section 109.6 Refunds. Section R112 Board of appeals. The board of appeals policy is established in Section 113 of the 2018 International Building Code. Section R113 Violations. The violations policy is established in Section 114 of the 2018 International Building Code. Section R114 Stop work orders. The stop work order policy is established in Section 115 of the 2018 International Building Code. Table R301.2(1) Climatic and Geographic Criteria. Ground Snow Load: Table R301.2(6) | 0 Ultimate Design Wind Speed: Basic Design Wind Speed: Tables R301.2(5)A, R301.2(5)B | 115 90 Exposure C Topographic Effects: | No Special Wind Region: | No Windborne Debris Zone: | No Climate Zone: IECC | 3B Hot-Dry Seismic Design Category: NEHRP map | B Weathering: Figure R301.2(4) | Negligible Frost Line: | 0 Termite: | Moderate to heavy Winter Design Temp: IPC Appendix D | 39 Ice Shield Under-layment Required: | No Flood Hazards: | City municipal code Chapter 15.36 Floodplain Regulations Air Freezing Index: NCDC Air Freezing Index-USA | NA Mean Annual Temp: | 70 Manual J Design: | Optional Rainfall,1-Hour (100 year) | 2" per hour (See table footnotes in IRC code book.) Section R301.2.2.6 Irregular buildings. 2. Lateral support of roofs and floors. Exception: (Add) 1. Portions of floors that do not support shear walls, braced wall panels above, or roofs shall be permitted to extend not more than 6 feet (1829 mm) beyond a shear wall or braced wall line. (Add) 2. For open sided patio covers, portions of trussed roofs that extend a maximum of 12' (3658 mm) beyond a shear wall or braced wall line may use the PFH portal frame with hold-downs method per Figure R602.10.6.2 or provide structural design by an Arizona licensed registrant. Table R302.1(1) Exterior Walls. EXTERIOR WALL ELEMENT | MINIMUM FIRE-RESISTANCE RATING | MINIMUM FIRE SEPARATION DISTANCE Walls | Fire-resistance rated | 1 hour assembly with exposure from both sides | 0 feet Not fire-resistance rated | 0 hours | >= 3 feet Projections | Not allowed | NA | < 2 feet Fire-resistance rated | 1 hour on the underside, heavy timber or fire retardant-treated wood. | >= 2 feet to <3 feet Not fire-resistance rated | 0 hours | >= 3 feet Openings in walls | Not allowed | NA | < 3 feet Unlimited | 0 hours | 3 feet Penetrations | All | Comply with Section R302.4 | < 3 feet None required | 3 feet (See table footnotes in IRC code book.) Section R303.4 Mechanical ventilation. A dwelling unit may be provided with whole-house mechanical ventilation in accordance with Section M1505.4. Section R313.2 One-and two-family dwellings automatic fire sprinkler systems. An automatic residential fire sprinkler system may be installed in one- and two-family dwellings. (Reference A.R.S. § 9-807) Section R322.1 General. (Add) 1. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section along with Chapter 15.36 Floodplain Regulations of the City code and Section 1612.3 of the International Building Code as amended. Section R404.4 Retaining walls. Retaining walls shall be constructed per the City of Bullhead City's standard retaining wall details or shall be designed by an Arizona licensed registrant. Section N1101.1 Scope. This chapter regulates the energy efficiency for the design and construction of buildings regulated by this code and all "R" occupancy buildings regulated by the International Building Code. Three options are provided; the option to be used is to be declared when construction documents are submitted for review. (Add) Option 1. Buildings may be designed in accordance with the 2018 International Energy Conservation Code, IECC-Residential Provisions as published; or (Add) Option 2. Buildings may be designed in accordance with Chapter 11 Energy Efficiency of this code as published; or (Add) Option 3. Building may be designed in accordance with Chapter 11 Energy Efficiency of this code as amended. Section N1101.5 (R103.2) Information on construction documents. (Delete—items 3 through 8) Chapter 11 Energy Efficiency. (Replace "Mandatory" with "Optional" in listed sections N1101.14 through N1104.1) Section N1101.14 (R401.3) Energy efficiency certificate (Optional). Section N1102.4 (R402.4) Air leakage (Optional). Section N1103.3.3 (R403.3.3) Duct testing (Optional). Section N1103.5.1 (R403.5.1) Heated water circulation and temperature maintenance systems (Optional). Section N1103.6 (R403.6) Mechanical ventilation (Optional). Section N1103.7 (R403.7) Equipment sizing and efficiency rating (Optional). Section N1103.10 (R403.10) Pools and permanent spa energy consumption (Optional). Section N1103.11 (R403.11) Portable spas (Optional). Section N1103.12 (R403.12) Residential pools and permanent residential spas (Optional). Section N1104.1 (R404.1) Lighting equipment (Optional). Section N1104.1.1 (R404.1.1) Lighting equipment (Optional). Figure N1101.7 Climate Zones. (Add) US States, Arizona, Mohave County, Declared climate zone is 3-Dry(B). Table N1102.1.2 Insulation and Fenestration Requirements by Components. COMPONENT R-values are minimums. U-factors and SHGC are maximums. | VALUE REQ'D Climate Zone | 3 Fenestration, U-factor b | 0.32 Skylight, U-factor b | 0.55 Glazed Fenestration, SHGC b,e | 0.25 Ceiling, R-value | 38 Wood Frame Wall, R-value | 20 or 13+5 Mass Wall, R-value i | 8/13 Floor, R-value | 19 Basement Wall, R-value c | 5/13 Slab, R-value and Depth d | 0 Crawl Space Wall, R-value c | 5/13 Supply and Return Ducts, R-value | 8 Ducts in Floor Trusses, R-value | 6 (See table footnotes in IRC code book.) Table N1102.1.4 Equivalent U-Factors. Declared climate zone is 3. Section M1307.3 Elevation of ignition source. Exemption: (Add) Domestic clothes dryers shall be exempt from this requirement. (Delete) Section M1411.8 Locking access port caps. Section M2003.1 General. (Add) Expansion tanks are required for all new construction water heater installations. Expansion tanks are not required for replacement water heater units when an expansion tank was not part of the original installation. Section G2415.3 (R404.3) Prohibited locations. (Add) Section G2415.3.1 Gas piping in accessory structures. Gas piping systems shall only be installed in structures with permanent foundations. Auger type tie-downs or similar devices shall not be considered permanent foundations. Section P2503.5.1 Rough plumbing. 1. Water test. Each section shall be filled with water to a point not less than 10 feet (3048 mm) above the highest fitting connection in that section, or to the highest point in the completed system. Water shall be held in the section under test for a period of 15 minutes. The system shall prove leak free by visual inspection. Section P2601 General. (Add) Section P2601.4 Plumbing systems in accessory structures. Plumbing systems shall only be installed in structures with permanent foundations. Auger type tie-downs or similar devices shall not be considered permanent foundations. Section P2603.5.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be regulated by the Mohave County Department of Public Health, Environmental Health Division. Building sewers shall be a minimum of 12 inches (304.8 mm) below grade. Section P2906.7 Flexible water connectors. Flexible water connectors, exposed to continuous pressure, shall conform to ASMEA112.18.6. Access shall be provided to all flexible water connectors. Flexible water connectors used must have metallic fittings when used to supply water to water closets, faucets, or ice makers. Section E3401.1 Applicability. (Add) Section E3401.1.1 Services above 400 amperes. Electrical plans submitted for services above 400 amperes shall be submitted and sealed by an Arizona licensed registrant. A qualified AZ Registrar of Contractors licensed contractor is required for services above 400 amperes. Section E3601.1 Scope. (Add) Section E3601.1.1 Electrical systems in accessory structures: Electrical systems shall only be installed in structures with permanent foundations. Auger type tie-downs or similar devices shall not be considered permanent foundations. Section E3604.2.1 Above roofs. (Add) Per the local electric utility provider conductors shall not be located over roofs. If utility provider permission is obtained in writing the installation is to meet the requirements of this section. Section E3608.1 Grounding electrode system. (Add) Two means of grounding are required. The primary grounding electrode shall be an 8 foot (2438 mm) long by 5/8 inch (15.88 mm) diameter driven rod. All supplemental grounding systems are open to any type allowed by the IRC or NEC. Section E3902.2 Garage and accessory building receptacles. (Add) Exception: The required GFCI outlet installed in the ceiling for the garage door opener may be replaced with a single outlet device. Section E3902.9 Laundry areas. (Add) Exception: The washer/dryer electrical outlet may be non-GFCI protected if the outlet is not readily accessible, and the outlet is no higher than 32 inches from the finished floor. Section E3902.10 Kitchen dishwasher branch circuit. (Add) Exception: The kitchen dishwasher electrical outlet may be non-GFCI protected. Section E3902.16 Arc-fault circuit-interrupter protection. Branch circuits that supply 120-volt, single-phase, 15- and 20-ampere outlets installed in bedrooms shall be protected by any of the following: (Remain—items 1 through 6 and Exemption)

(Ord. No. 2024-09, § 1, 4-16-2024; Ord. No. 2012-7, § 1, 6-5-2012; Ord. No. 2009-16, § 2, 6-2-2009; Ord. 2008-17, § 1; Ord. 2006-58, § 5; Ord. 2005-45, § 4.2)

Ask a question about Bullhead City law

Corpus searches the Bullhead City sections it holds and shows the ones that match, with their citations. Free, no sign-in.