For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.34.130 — Violations and penalties

Municipal Code of the City of Bullhead City, Arizona (Codified through Ordinance No. 2026-14, enacted August 17, 2026. (Supp. No. 75)) · Bullhead City Municipal Code § 17.34.130

Corpus is an independent public-information project, not the official City of Bullhead City website. Stable reference: corpuslaw.us/code/076c0625-52fa-4404-8193-0cb6ef77f8e2

17.34.130 - Violations and penalties.

A. Any person, firm or corporation violating any regulation or provision of this chapter is guilty of a Class 1 misdemeanor. Each and every day during such violation continues is a separate offense. B. A violation of any regulation or provision of this chapter shall be punishable by a fine of not more than two thousand five hundred dollars or by imprisonment in the county jail for a term not exceeding six months or by both such fine and imprisonment for each conviction. C. All such remedies provided in this section shall be cumulative and not exclusive. The conviction of any person, firm or corporation hereunder shall not relieve such person from the responsibility to correct such violation, nor prevent the enforcement, correction or removal thereof. Table 17.34.050 NOISE ATTENUATION MATRIX CODE RESTRICTIONS NOZ-0 | NOZ-1 | NOZ-2 | NOZ-3 | CZO Residential Single-family, multifamily, manufactured or modular housing, and mobile homes | 1, 2 | N. P. | N. P. | N. P. Recreational vehicle parks | N. P. | N. P. | N. P. Other residential | 1, 2 | N. P. | N. P. | N. P. Public Facilities Educational facilities | 1, 2 | N. P. | N. P. | N. P. Religious facilities, libraries, museums, galleries, clubs and lodges | 1, 2 | N. P. | N. P. | N. P. Outdoor sports events, entertainment and public assembly, except amphitheaters | 1, 2 | N. P. | N. P. | N. P. Indoor recreation, amusement, athletic clubs, gyms and spectator events | 1, 3 | N. P. | N. P. Community and regional parks | N. P. | N. P. Outdoor recreation: tennis courts, golf courses, riding trails, etc. | N. P. Cemeteries | N. P. Commercial Hotels/motels | 1, 2 | N. P. | N. P. | N. P. Hospitals and other health care services | 1, 2 | N. P. | N. P. | N. P. Services: finance, real estate, insurance, professional and government offices | 1, 2 | N. P. | N. P. | N. P. Retail sales: building materials, automotive, marine, mobile homes, recreational vehicles and accessories | 1, 3 | N. P. | N. P. Retail sales: general merchandise, food, drugs, apparel, etc. | 1, 3 | N. P. | N. P. Restaurants, eating and drinking establishments | 1, 3 | N. P. | N. P. Personal services: barber and beauty shops, laundry and dry cleaning, etc. | 1, 3 | N. P. | N. P. Automotive service stations Repair services | 4 | N. P. Industrial Processing of food, wood and paper products; printing and publishing, warehouses, wholesale and storage activities | 4 | N. P. Refining, manufacturing and storage of chemicals, petroleum and related products, manufacturing and assembly of electronic components, etc. | 4 | N. P. Manufacturing of stone, clay, glass, leather, gravel and metal products; construction and salvage yards; natural and resource extraction and processing, mills and gins | 5 | 5 | N. P. Miscellaneous Transportation terminals, utility and communication facilities | N. P. Vehicle parking | 7 | N. P. Signs NOISE ATTENUATION MATRIX CODE RESTRICTIONS Table 17.34.060A TWENTY-FIVE DECIBEL NOISE LEVEL REDUCTION STANDARD Compliance with the following standards shall be deemed to meet requirements for a minimum noise level reduction (NLR) of twenty-five decibels. A. General: 1. Brick veneer, masonry blocks, or stucco exterior walls shall be constructed airtight. All joints shall be grouted or caulked airtight. 2. At the penetration of exterior walls by pipes, ducts or conduits, the space between the wall and pipes, ducts or conduits shall be caulked or filled with mortar. 3. Window and/or through-the-wall ventilation units shall not be used. 4. Through-the-wall/door mailboxes shall not be used. B. Exterior Walls: 1. Exterior walls, other than as described in this section, shall have a laboratory sound transmission class rating of at least STC-30. 2. Masonry walls have a surface weight of at least twenty-five pounds per square foot do not require a furred (stud) interior wall. At least one surface of concrete block walls shall be plastered. 3. Stud walls shall be at least 4 inches in nominal depth and shall be finished on the outside with siding-on-sheathing, stucco or brick veneer. a. Interior surface of the exterior walls shall be of gypsum board or plaster at least one-half-inch thick, installed on the studs. b. Continuous composition board, plywood or gypsum board sheathing at least one-half-inch thick shall cover the exterior side of the wall studs behind wood or metal siding. Asphaltic or wood shake shingles or plaster (stucco) are acceptable in lieu of siding. c. Sheathing panels shall be covered on the exterior with overlapping building paper. d. Insulation material at least R-11 shall be installed continuously throughout the cavity space behind the exterior sheathing and between wall studs. Insulation shall be glass fiber or mineral wool. C. Windows: 1. Windows other than as described in this section shall have a laboratory sound transmission class rating of at least STC-28. 2. Glass shall be at least three-sixteenths-inch thick. 3. All operable windows shall be weather stripped and airtight when closed so as to conform to an air infiltration test not to exceed 0.5 cubic foot per minute per foot of crack length in accordance with ASTM E-283-65-T. 4. Glass of fixed-sash windows shall be sealed in an airtight manner with a nonhardening sealant or a soft elastomer gasket or gasket tape. 5. The perimeter of window frames shall be sealed airtight to the exterior wall construction with a sealant conforming to one of the following federal specifications: TT-S-0027, TT-S-00230 or TT-S- 00153. 6. Total area of glass shall not exceed twenty percent of total exterior wall area. D. Doors: 1. Doors other than as described in this section shall have a laboratory sound transmission class rating of at least STC-26. 2. All exterior sidehinged doors shall be solidcore wood or insulated hollow metal at least one and three-fourth inches thick and shall be fully weather stripped. 3. Exterior sliding doors shall be weather stripped with an efficient airtight gasket system with performance as specified in subsection (C)3. The glass in the sliding doors shall be at least three-sixteenth inch thick. 4. Glass in doors shall be sealed in an airtight nonhardening sealant or in a soft elastomer gasket or glazing tape. 5. The perimeter of door frames shall be sealed airtight to the exterior wall construction as described in subsection (C) 5. E. Roofs: 1. Combined roof and ceiling construction other than described in this subsection and subsection F shall have a laboratory sound transmission class rating of at least STC-39. This requires an acoustical analysis or test. 2. With an attic or rafter space at least six inches deep, and with a ceiling below, the roof shall consist of one-third inch composition board, plywood or gypsum board sheathing topped by roofing as required. 3. Open beam roof construction shall follow the energy insulation standard method for batt insulation. 4. Skylights shall conform to a STC rating of 28. F. Ceilings: 1. Gypsum board or plaster ceilings at least one-half-inch thick shall be provided where required by subsection (E)2, above. Ceilings shall be substantially airtight with a minimum of penetrations. 2. Glass fiber or mineral wood insulation at least R-19 shall be provided above the ceiling between joist. G. Floors: 1. Openings to any crawl spaces below the floor of the lowest occupied room shall not exceed two percent of the floor area of the occupied rooms. H. Ventilation: 1. A mechanical ventilation system shall be installed that will provide the minimum air circulation and fresh air supply requirements for various uses in occupied rooms without the need to open any windows, doors or other openings to the exterior. The attic inlet and discharge openings shall be fitted with sheet metal transfer ducts of at least 20-gauge steel, which shall be lined with one-inch thick coated glass fiber, and shall be at least five feet long with one ninety degree bend. 2. Gravity vent openings in attics shall not exceed code minimum in number and size. 3. All vent ducts (except kitchen and sewer gas ducts) connecting the interior space to the outdoors, excepting domestic range exhaust ducts, shall contain at least a five-foot length of internal sound-absorbing duct lining. Each duct shall be provided with a bend in the duct such that there is no direct line-of-sight through the duct from the venting cross-section to the room opening cross-section. Duct lining shall be coasted glass fiber duct liner at least one inch thick. 4. Fireplaces shall be provided with well-fitted dampers. Table 17.34.060B THIRTY DECIBEL NOISE LEVEL REDUCTION STANDARDS Compliance with the following standards shall be deemed to meet requirements for a minimum noise level reduction of thirty decibels. A. General: 1. Brick veneer, masonry blocks, or stucco exterior walls shall be constructed airtight. All joints shall be grouted or caulked airtight. 2. At the penetration of exterior walls by pipes, ducts or conduits, the space between the wall and pipes, ducts or conduits shall be caulked or filled with mortar. 3. Window and/or through-the-wall ventilation units shall not be used. 4. Operational-vented fireplaces shall not be used. 5. All sleeping spaces shall be provided with a carpeted floor. 6. Through-the-wall/door mailboxes shall not be used. B. Exterior Walls: 1. Exterior walls, other than as described in this section, shall have a laboratory sound transmission class rating of at least STC-35. 2. Masonry walls have a surface weight of at least forty pounds per square foot do not require a furred (stud) interior wall. At least one surface of concrete block walls shall be plastered. 3. Stud walls shall be at least four inches in nominal depth and shall be finished on the outside with siding-on-sheathing, stucco or brick veneer. a. Interior surface of the exterior walls shall be of gypsum board or plaster at least one-half-inch thick, installed on the studs. The gypsum board or plaster may be fastened rigidly to the studs if the exterior is brick veneer or stucco. If the exterior is siding-on-sheathing, the interior gypsum board or plaster must be fastened resiliently to the studs. b. Continuous composition board, plywood, plaster (stucco), or gypsum board sheathing at least three-fourths inch thick shall cover the exterior side of the wall studs behind wood or metal siding. c. Sheathing panels shall be covered on the exterior with overlapping building paper. d. Insulation material at least R-11 shall be installed continuously throughout the cavity space behind the exterior sheathing and between wall studs. Insulation shall be glass fiber or mineral wool. C. Windows: 1. Windows other than as described in this section, shall have a laboratory sound transmission class rating of at least STC-33. 2. Glass of double-glazed windows shall be at least one-eighth inch thick. Panes of glass shall be separated by a minimum one-half-inch airspace. 3. Double-glazed windows shall employ fixed sash or efficiently weather stripped, operable sash. The sash shall be rigid and weather stripped with material that is compressed airtight when the window is closed so as to conform to an infiltration test not to exceed 0.5 cubic foot per minute per foot of crack length in accordance with ASTM E-283-65-T. 4. Glass of fixed-sash windows shall be sealed in an airtight manner with a nonhardening sealant or a soft elastomer gasket or glazing tape. 5. The perimeter of window frames shall be sealed airtight to the exterior wall construction with a sealant conforming to one of the following federal specifications: TT-S-00227, TT-S-00230 or TT-S- 00153. 6. Total area of glass shall not exceed twenty percent of total exterior wall area. D. Doors: 1. Doors, other than as described in this section, shall have a laboratory sound transmission class rating of at least STC-33. 2. Double-door construction is required for all door openings to the exterior. Openings fitted with sidehinged doors shall have one solid core wood or insulated hollow metal core door at least one and three-fourths inch thick separated by an airspace of at three inches from another door, which can be a storm door. Both doors shall be tightly fitted and weather stripped. 3. The glass of doubleglazed sliding doors shall be separated by a minimum one-half-inch airspace. Each sliding frame shall be provided with an efficiently airtight weather stripping material as specified in subsection (C)3. 4. Glass of all doors shall be at least three-sixteenths-inch thick. Glass of double sliding doors shall not be equal in thickness. 5. The perimeter of door frames shall be sealed airtight to the exterior wall construction as indicated in subsection (C) 5. 6. Glass of doors shall be set and sealed in an airtight nonhardening sealant or a soft elastomer gasket or glazing tape. E. Roofs: 1. Combined roof and ceiling construction, other than described in this section and subsection (F), shall have a laboratory sound transmission class rating of at least STC-44. 2. With an attic or rafter space at least six inches deep, and with a ceiling below, the roof shall consist of three-fourths inch composition board, plywood or gypsum board sheathing topped by roofing as required. 3. Open beam roof construction shall follow the energy insulation standard method for batt insulation, except use one inch plywood decking with shakes or other suitable roofing material in place of one-half-inch plywood. 4. Window or dome skylights shall have a laboratory sound transmission class rating of at least STC-33. F. Ceilings: 1. Gypsum board or plaster ceilings at least five-eighths inch thick shall be provided where required by subsection (E) 2, above. Ceilings shall be substantially airtight with a minimum number of penetrations. 2. Glass fiber or mineral wood insulation of at least R-19 shall be provided above the ceiling between joist. G. Floors: 1. The floor of the lowest occupied rooms shall be slab on fill, below grade, or over a fully enclosed basement or crawl space. All door and window openings in the fully enclosed basement shall be tightly fitted. H. Ventilation: 1. A mechanical ventilation system shall be installed that will provide the minimum air circulating and fresh air supply requirements for various uses in occupied rooms without the need to open any windows, doors or other openings to the exterior. The attic inlet and discharge openings shall be fitted with sheet metal transfer ducts of at least 20-gauge steel, which shall be lined with one inch thick coated glass fiber, and shall be at least five feet long with one ninety degree bend. 2. Gravity vent openings in attics shall not exceed code minimum in number and size. The openings shall be fitted with transfer ducts at least three feet in length containing internal one inch thick coated fiberglass sound absorbing duct lining. Each duct shall have a lined ninety-degree bend in the duct such that there is no direct line-of-sight from the exterior through the duct into the attic. 3. All vent ducts connecting the interior space to the outdoors, excepting domestic range exhaust and sewer gas ducts, shall contain at least a ten foot length of internal sound-absorbing duct lining. Each duct shall be provided with a lined ninety degree bend in the duct such that there is no direct line-of- sight through the duct from the venting cross-section to the room-opening cross-section. Duct lining shall be coasted glass fiber duct liner at least one inch thick. 4. Domestic range exhaust ducts connecting the interior space to the outdoors shall contain a selfclosing baffle plate across the exterior termination which allows proper ventilation. The duct shall be provided with a ninety degree bend or other mitigating measures approved by the building official.

(Ord. 97-905 § 1 (part); Ord. 91-499 § 2 (part), 1991) (Ord. 97-905 § 1 (part); Ord. 91-499 § 2 (part), 1991) (Ord. 97-905 § 1 (part); Ord. 91-499 § 2 (part), 1991) (Ord. 97-905 § 1 (part); Ord. 91-499 § 2 (part), 1991)

Ask a question about Bullhead City law

Corpus searches the Bullhead City sections it holds and shows the ones that match, with their citations. Free, no sign-in.