15.08.061 - Amendments to the International Residential Code.
The International Residential Code is amended as follows: A. Section R101.1, Title, is amended to read as follows: R10l.1 Title. These provisions shall be known as the Residential Code for One- and Two-family Dwellings of the City of Cottonwood, and shall be cited as such and will be referred to herein as "this code." B. Section R105.2, Work exempt from permit, is amended to amend 1 and 5 under the "Building" category to read as follows: 1. One-story, grade level, detached, non-habitable accessory structures, provided the floor area does not exceed 200 square feet and the building height does not exceed twelve feet (12') at the highest point of the roof or wall. 5. Driveways, sidewalks, and patios that are not more than 30" above grade at any point. C. Section R105.2, Work exempt from permit, is amended to add the following items under the "Building" category: 11. Roof assembly repair in which no more than 100 square feet of the roofing assembly is replaced or repaired and does not require removal or displacement of mechanical, plumbing, or electrical systems. 12. Replacement of exterior finishes, provided that the removal or replacement does not compromise the structural integrity and moisture barrier of the building. D. Section R105.5. Expiration, is amended to add Section R105.5.1. Model home plan expiration, to read as follows: R105.5.1 Model home plan expiration. Model home plans shall expire upon the adoption of a new Residential Code. E. Section R106.1.1, Information on construction documents, is amended to read as follows: R106.1.1 Information on construction documents. Construction documents shall be drawn upon suitable material. Electronic media documents are permitted to be submitted where approved by the building official. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code and relevant laws, ordinances, rules and regulations, as determined by the building official. Submitted documents shall identify the scope of work (project summary) and reference the City's adopted design codes. F. Section R109.3, Inspection requests, is amended to add Section R109.3.1, Elevated work and rooftop inspections, to read as follows: R109.3.1 Elevated work and rooftop inspections. For all elevated work and rooftop inspections, adequate fall protection measures shall be in place to ensure the safety of inspectors. The permit holder or contractor shall provide and maintain approved fall protection systems, including but not limited to: 1. Guardrails - Installed in accordance with OSHA and building code requirements. 2. Safety Nets - Positioned and maintained to prevent falls where guardrails are not feasible. 3. Personal Fall Arrest Systems - Properly anchored and utilized when required. 4. Other alternate safety methods approved by the Building Official. The permit holder or contractor is responsible for ensuring compliance with all applicable safety regulations before an inspection is conducted. If fall protection cannot be provided, the permit holder or property owner must sign a liability indemnification waiver, indemnifying and holding the City and its inspectors harmless from any injuries or claims arising from the inspection. The Building Official reserves the right to deny or postpone inspections if adequate safety measures are not in place. G. Section R110.3, Temporary occupancy, is amended to read as follows: Section R110.3 Temporary occupancy. The issuance of Temporary Certificates of Occupancy is not customary and shall be reviewed by the Community Development Director after the submittal of a written request identifying the hardship(s) not caused directly or indirectly by the applicant, property owner, design professionals, or contractors. Upon approval of the Community Development Director to allow issuance of a Temporary Certificate of Occupancy, the owner shall submit to the Building Official for review and approval a letter requesting temporary occupancy for a period of time to be approved by the Building Official and include with the request: 1. An itemization of all work authorized and required by the building and grading permits that must be completed to permanently occupy the building. 2. An irrevocable bond or other financial deposit acceptable to the Building Official and payable to the City of Cottonwood in the event construction is not completed before the expiration of the Temporary Certificate of Occupancy. The amount of the bond or deposit shall equal 100 percent of the construction cost to complete the work required by the permits. 3. For the purpose of this section, construction cost shall include all labor, materials, equipment, sales tax, permit fees, and contractors' profit and overhead plus a twenty percent (20%) contingency amount for unforeseen construction expenses and City administration in the event the City undertakes the completion of the project. The Building Official may require written proposals or estimates from contractors to substantiate the amount of the bond or deposit. 4. The payment of a non-refundable fee for the Temporary Certificate of Occupancy shall be $200.00 for single-family dwellings and $500.00 for commercial projects. 5. A written agreement that the bond or deposit is forfeited by the owner to the City in the event all required work is not completed before the expiration of the Temporary Certificate of Occupancy and authorization for the City to undertake and complete construction with the forfeited funds. If the City undertakes the completion of the project with the forfeited funds, any unexpended amount shall be returned to the owner or bonding agent as applicable. If costs to complete the project exceed the amount of the bond or deposit, the City may file a lien against the subject property and take appropriate action as necessary to recover all the additional expenses incurred completing the construction. The Building Official may extend the time period of an original Temporary Certificate of Occupancy or issue one or more additional temporary certificates if conditions beyond the control of the owner prevent project completion by the expiration of the original Temporary Certificate. Extensions and additional temporary certificates shall be requested by the owner before the expiration of the original certificate and approved by the Building Official in the same manner as the original certificate. The owner shall provide a bond or deposit and pay a new fee for each extension or additional certificate. EXCEPTION: Public schools are not required to provide a bond or deposit for the completion of work or pay temporary certificate fees. H. Section R114.2, Issuance, is amended to read as follows: R114.2 Issuance. The stop work order shall be in writing and shall be given to the owner of the property, the owner's authorized agent or the person performing the work. Posting of the Stop Work order on the structure or property in question shall be deemed proper notification to the owner or owner's authorized agent. Upon issuance of a stop work order, the cited work shall immediately cease. The stop work order shall state the reason for the order and the conditions under which the cited work is authorized to resume. I. Section R114.3, Emergencies, is deleted in its entirety. J. Chapter 1, Scope and Administration, is amended to add Section R115, Unsafe Structures and Equipment, to read as follows: SECTION R115 UNSAFE STRUCTURES AND EQUIPMENT R115.1 General. Unsafe structures and equipment shall comply with the provisions of Section 116 of the International Building Code. K. Section R202.2, Definitions, is amended to add the following definition: ELEVATED WORK. A walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level. L. Table R301.2, Climate and Geographical Design Criteria, is amended to populate the table with the following items, each in its respective field: Ground Snow Load: 20 lbs. per sq. ft. Wind Design: Speed: 110 mph Topographical Effects: No Special Wind Region: No Windborne Debris Zone: No Seismic Design Category: C Subject to Damage From: Weathering: Moderate Frost Line Depth: 12" Termite: Moderate to Heavy Ice Barrier Underlayment Required: No Flood Hazards: Flood hazard areas shall be designated and regulated by the adopted regulations of the appropriate, governing county or city agency having flood management jurisdiction. Air Freezing Index: 65 Mean Annual Temp: 59.9°F. Manual J Design Criteria: Elevation: 3375 Altitude Correction Factor: 0.98 Coincident Wet Bulb: 66 Indoor Winter Design Relative Humidity: 40% Indoor Winter Design Dry-Bulb Temperature: 70°F Outdoor Winter Design Dry-Bulb Temperature: 20°F Heating Temperature Difference: 50°F Latitude: 35 Daily Range: 30 Summer Design Gains 50% RH (amended): -23 Indoor Summer Design Relative Humidity: 50% Indoor Summer Design Dry-Bulb Temperature: 75°F Outdoor Summer Design Dry-Bulb Temperature: 91°F Cooling Temperature Difference: 16°F M. Section R328, Swimming Pools, Spas and Hot Tubs, is amended to add Section R328.2, Barriers, to read as follows: R328.2 Barriers. A pool enclosure complying with A.R.S. § 36-1681 shall be provided prior to filling with water regardless of residents' age. Barrier requirements between the residence or living area and the swimming pool or other contained body of water regulated by A.R.S. § 36-1681 may be omitted where all of the following exist: A residence in which all residents are at least 6 years of age and a notarized affidavit confirming the age restriction is submitted to the building official. All operable windows having a sill height of less than 48 inches (1219 mm) above the indoor finished floor, doors, and gates shall have an alarm that produces an audible warning when the window, door, or screens are opened. The alarm shall be listed and labeled as a water hazard entrance alarm in accordance with UL 2017. Alternatively, a motorized, locking pool cover complying with ASTM Fl346-23 is installed. N. Section R330.2, Equipment listings, is amended to delete the exception in its entirety. O. Chapter 3, Building Planning, is amended to add Section R333, Lot Boundary Identification, to read as follows: SECTION R333 LOT BOUNDARY IDENTIFICATION. R333.1 General. If lot comer identification markers are missing or unverifiable, the Building Official may require a lot boundary survey. The property owner or applicant shall bear the cost of the survey, which must be conducted by a registrant licensed by the Arizona State Board of Technical Registration. The survey shall permanently establish and identify lot boundary markers in compliance with State law. P. Section R403.1.1, Minimum size, is amended to add Section R403.1.1.1, Minimum footing reinforcement, to read as follows: R403.l.l.1 Minimum footing reinforcement. Continuous strip concrete footings shall be reinforced with at least two #4 horizontal reinforcement bars located 3 inches from the bottom of the footing. Monolithic interior and exterior concrete footings shall be reinforced with at least one #4 horizontal reinforcement bar located 3 inches from the bottom of the footing and one #4 located 3 inches from the top of the slab. Pier and column footings shall be reinforced with #4 horizontal reinforcement spaced no more than 12 inches in each direction and located 3 inches from the bottom of the footing. Q. Section R404.1.2.1, Masonry foundation walls, is amended to read as follows: R404.1.2.1 Masonry foundation walls. Concrete masonry and clay masonry foundation walls shall be constructed as set forth in Table R404.1.2.1 (2), R404.1.2.1(3) or R404.1.2.1 (4) and shall comply with applicable provisions of Section R606. In buildings assigned to Seismic Design Categories Do, D1 and D2, concrete masonry and clay masonry foundation walls shall also comply with Section R404.1.4.1. Rubble stone masonry foundation walls shall be constructed in accordance with Sections R404.1.8 and R606.4.2. Rubble stone masonry walls shall not be used in Seismic Design Categories Do, D1 and D2, or in townhouses in Seismic Design Category C. R. Table R404.1.2.1(1), Plain masonry foundation walls, is deleted in its entirety. S. Section R506.3.3, Vapor retarder, is deleted in its entirety. T. Section R702.7, Vapor retarders, exceptions 4 and 5 are amended to read as follows: 4. A vapor retarder shall not be required in Climate Zones 1, 2, 3, and 4. 5. In Climate Zones 5 through 8, vapor retarder shall not be required where the assembly complies with Table R702.7(5). U. Chapter 9, Roof Assemblies, is amended to delete all references to "wood shingles" or "wood shakes," except for Section R902.2. V. Section R902.1, Roof assemblies, is amended to read as follows: R902.1 Roof assemblies. Roof decks shall be covered with materials as set forth in Section R904 or with roof coverings as set forth in Section R905. Roof assemblies shall be Class A or B. Where the edge of the roof deck is less than 3 feet (914 mm) from a lot line, the roof assembly shall be Class A. Class A and B roof assemblies shall be tested in accordance with ASTM EI 08 or UL 790. Roof assemblies shall be listed and identified as to class by an approved testing agency. W. Chapter 11, Energy efficiency, is deleted in its entirety and replaced with Chapter 11 of the 2018 International Residential Code, and amended as follows: 1. Section N1101.14, Certificate, is deleted in its entirety. 2. Section N1102.4.1.2, Testing, is amended to add the following exception: EXCEPTION: Where the items listed in Table N1102.4.1.1, applicable to the method of construction, are field verified. Where required by the code official, an approved party, independent from the installer of the insulation, shall inspect the air barrier and insulation. X. Section P2604, Trenching and backfilling, is amended to add Section P2604.5, Tracer wire, to read as follows: P2604.5 Tracer wire. For plastic sewer piping, an insulated copper tracer wire or other approved conductor shall be installed adjacent to and over the full length of the piping. Access shall be provided to the tracer wire or the tracer wire shall terminate at the cleanout between the building drain and building sewer. The tracer wire size shall be not less than 18 American Wire Gauge (2.5 mm 2 ) and the insulation type shall be listed for direct burial. Y. Appendix BB, Tiny Houses, Section BB106.I, Air leakage testing, is amended to add the following exception: EXCEPTION: Where the items listed in Table N1102.4.1.1, applicable to the method of construction, are field verified. Where required by the code official, an approved party, independent from the installer of the insulation, shall inspect the air barrier and insulation. Z. Appendix BB, Tiny Houses, is amended to add Section BB107, Additional Requirements and Allowances, to read as follows: SECTION BB107 ADDITIONAL REQUIREMENTS AND ALLOWANCES. BB107.1 Egress door. The main egress door shall be no less than 32" in width. BB107.2 Room dimensions. The minimum room dimension of a habitable room, other than the loft or kitchen, shall be 6'-6", and the room area shall be no less than 60 sq. ft. BB107.3 Foundation. Tiny houses shall be built on, and permanently attached to full, continuous concrete or masonry foundations. 88107.4 General. Tiny houses shall comply with all other requirements of the adopted International Residential Code. AA. Section 80101.1, General, is amended to read as follows: 8D101.1 General. This appendix shall apply to a home daycare operated within a dwelling and complying with the requirements of A.R.S. §§ 36-897 through 36-897.13. It is to include buildings and structures occupied by persons of any age who receive custodial care for less than 24 hours by individuals other than parents or guardians or relatives by blood, marriage, or adoption, and in a place other than the home of the person cared for.
(Ord. No. 761, § 5, 5-20-2025)
Ask a question about Cottonwood law
Corpus searches the Cottonwood sections it holds and shows the ones that match, with their citations. Free, no sign-in.