§ 15.08.071 — Amendments to the International Fuel Gas Code
Municipal Code of the City of Cottonwood, Arizona (Codified through Ordinance No. 767, passed April 21, 2026. (Supp. No. 26, (8/26), Update 2)) · Cottonwood Municipal Code § 15.08.071
Corpus is an independent public-information project, not the official City of Cottonwood website. Stable reference: corpuslaw.us/code/acc609fb-bb86-41f2-9f9a-8cbd832d71c7
15.08.071 - Amendments to the International Fuel Gas Code.
The International Fuel Gas Code is amended as follows: A. Section 101.1, Title, is amended to read as follows: 101.1: Title. These regulations shall be known as the Fuel Gas Code of the City of Cottonwood, hereinafter referred to as "this code." B. Section 114.2, Issuance, is amended to read as follows: 114.2: Issuance. The stop work order shall be in writing and shall be given to the owner of the property, the owner's authorized agent or the person performing the work. Posting of the stop work order on the structure or property in question shall be deemed proper notification to the owner or owner's authorized agent. Upon issuance of a stop work order, the cited work shall immediately cease. The stop work order shall state the reason for the order and the conditions under which the cited work is authorized to resume. C. Section 404.12, Minimum Burial Depth, is amended to read as follows: 404.12: Minimum burial depth. Underground piping systems shall be installed a minimum depth of 12 inches (305 mm) below grade, except as provided for in Section 404.12.1. However, in cases other than that specified in Section 404.12.1, underground plastic piping systems shall be installed a minimum depth of 18 inches below grade to the top of the pipe. D. Section 404.12.1, Individual outdoor appliances, is amended to read as follows: 404.12.1: Individual outdoor appliances. Individual lines to outdoor lights, grills and other appliances shall be installed not less than 8 inches (203 mm) below finished grade, provided that such installation is approved and is installed in locations not susceptible to physical damage. However, in such cases, underground plastic piping systems shall be installed a minimum depth of 12 inches to the top of the pipe or in accordance with the manufacturer's installation guidelines, whichever is deeper. E. Section 406.4.1, Test pressure, is amended to read as follows: 406.4.1: Test pressure. The test pressure to be used shall be not less than 1 1/2 times the proposed maximum working pressure, but not less than 5 psig (34 kPa gauge). Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
(Ord. No. 761, § 7, 5-20-2025)
Ask a question about Cottonwood law
Corpus searches the Cottonwood sections it holds and shows the ones that match, with their citations. Free, no sign-in.