Sec. 107-3.2. - General standards.
A. All fixtures installed anywhere in the city shall at a minimum be full cut-off fixtures; excluding seasonal holiday lighting, decorative string lighting for outdoor seating areas, low-output ground-mounted lights directed at trees, monument signs, and other decorative features, and landscape light fixtures not exceeding one thousand (1,000) lumens per luminaire. Other exceptions to full cut-off fixtures may be approved on a case-by-case basis by the community development director provided it can be shown that the proposed fixture includes alternative technology luminaries or artistic attachments/shields that provide similar photometric results as full cut-off fixtures. B. Internal or external shields may be required on some installations depending on location and adjacent land uses. Internal shields are preferred on new installations. External shields shall be treated to be non-reflective. See Figure 107-3a. [image omitted; see the official code] Figure 107-3a C. The maximum light output per acre for new commercial, industrial, mixed use, and multi-family residential developments in the LZ2 lighting zone shall not exceed one hundred fifty thousand (150,000) lumens per acre when adjacent to residential and two hundred thousand (200,000) lumens when not adjacent to residential in order to control the amount of visible light on the property and thus reducing the overall brightness. D. Outdoor lighting installations shall be served by underground electrical service and include adaptive controls, including but not limited to, timers, dimmers and/or sensors in order to reduce overall energy consumption, eliminate unnecessary lighting, and to comply with the city's automatic lighting reduction requirements of Section 107-3.4 herein. E. The city is not mandating a specific design, material or lighting fixture. Below, for illustrative purposes only, are examples of both unacceptable and acceptable lighting fixtures for use in the city. See Figure 107-3b. F. Exceptions to the standards contained herein may be approved at the discretion of the community development director. [image omitted; see the official code] Figure 107-3b G. The style of light standards and fixtures should be consistent with the style and architectural character of the proposed development site and in compliance with the light source and shielding requirements for the specific lighting zone per Table 107-3a below. The pedestals for pole-mounted fixtures are to be finished in a manner and with a material that complements the architectural character of the proposed development site. H. All light fixtures, including security lighting, shall be located, aimed, and shielded so that the direct illumination from the fixture will be confined entirely within the property boundaries of the source. I. The overall height shall be measured from the finished grade to the top of the light fixture. Any pedestals upon which pole-mounted fixtures are placed shall be included in the overall height measurement. Exceptions to the height limitations shall be allowed only for those structures and facilities where lighting must be used to illuminate potential obstructions and/or hazards to air navigation. J. An approved site lighting plan photometric indicating the lighting zone, type of light source, fixture detail, and schedule is required prior to the issuance of a building permit.
(Ord. No. 2023-25, § 1(Exh. A), 11-6-23)
Ask a question about Surprise law
Corpus searches the Surprise sections it holds and shows the ones that match, with their citations. Free, no sign-in.