For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 107-3.3 — Outdoor lighting zones and lighting uses

Municipal Code of Surprise, Arizona (Supp. No. 68: codified through Ordinance No. 2026-07, adopted January 20, 2026) · Surprise Municipal Code § 107-3.3

Corpus is an independent public-information project, not the official City of Surprise website. Stable reference: corpuslaw.us/code/8c61210c-6319-41e1-8713-360b7c2d614d

Sec. 107-3.3. - Outdoor lighting zones and lighting uses.

A. There are different lighting zones throughout the city. The lighting source, shielding requirements, and automatic lighting reductions are determined by both the lighting zone and the specific use of the property. The lighting zones are further delineated as follows: 1. Lighting zone 2 (LZ2). Areas within this lighting zone includes the neighborhood areas that are developed at the suburban and urban level, high use recreational and play fields, commerce and office areas of the city, and within the transit oriented development district as designated by the city General Plan. Lighting levels in the LZ2 are medium to high ambient brightness due to the higher levels of night time activity and the concentration and types of land uses allowed by the zoning district; .....i§ particularly where color rendition is important for the effectiveness and safety of the permitted activities. 2. Lighting zone 1 (LZ1). Areas within this lighting zone includes the neighborhood area that is developed as large lot single-family, rural residential, and surrounding natural open space as well as business parks and industrial areas with limited nighttime activity. Lighting levels in the LZ1 are low ambient brightness with general illumination for safety or security focused at activity centers and along travel corridors. 3. Lighting zone 0 (LZ0). Areas within this lighting zone includes those lands within a scenic lands development area as designated by the city General Plan and for other lands determined to have environmentally sensitive features or to be located in environmental buffer areas. In these areas, the preservation of an intrinsically dark environment both in the sky and in the visible landscape is considered of paramount value and special review will be required for any permanent lighting in this zone. 4. A property located in more than one (1) of the lighting zones described in subsections 1 to 3 above shall be considered to be only in the more restrictive lighting zone. B. The lighting zones delineated in Section 107-3.3 above have specific permitted/prohibited lighting sources and shielding requirements associated with them as outlined in the following Table 107-3a and in other subsections herein. Table 107-3a—Allowed Lighting and Shielding Standards Lighting Activities in Lighting Zones | LZ2 | LZ1 | LZ0 Street lighting | N/A (8) | N/A (8) | N/A (8) Parking lot lighting | LED, MH, (2), (5), (7) | LED, MH, (2), (5), (7) | LED, (1),(6),(7) School and community facilities such as sports field/court and play area lighting | LED, MH, (1),(6),(7) | LED, MH, (1), (6), (7) | LED, MH, (1), (6), (7) Architectural/structural illumination | LED, (1) | LED, (1) | LED, (1), (6) Landscape lighting (trees, shrubs, open space features) | LED, (2) | LED, (2) | LED, (1), (6) Vehicular sales lot lighting | LED, MH, (1), (5), (7) | X | X Outdoor display and sales area lighting | LED, MH, (1), (5), (7) | LED, MH, (1), (5), (7) | X Building overhangs and open canopies | LED, MH, (1), (5), (7) | LED, MH, (1), (5), (7) | LED, (1), (6) Plazas and outdoor seating areas at eating and drinking establishments | LED, (3), (4), (5) | LED, (3), (4), (5) | LED, (3), (4), (5) Security lighting | LED, MH, (1), (7) | LED, MH, (1), (7) | LED, (1), (7) Walkways and trails | LED, MH, (2), (5), (7) | LED, MH, (2), (5), (7) | LED, (1), (6) Agricultural uses: arenas, corrals and animal containment areas | X | MH, LED, (2), (6) | X Notes: (1) Full cut-off (2) Partially shielded (3) Unshielded—shielding not required but highly recommended (4) Decorative unshielded low-wattage incandescent lamps will be permitted (5) Lighting reductions are required (6) Lighting shut-off required (7) Adaptive controls required (8) Refer to "Surprise Street Light Design Guidelines" for street light standards Light source code: LED = filtered to have a correlated color temperature (CCT) maximum of 3,000K unless otherwise indicated MH = metal halide X = not allowed C. Lighting reductions and/or shut off is not required for any of the following: 1. With the exception of landscape lighting, lighting for multi-family residential properties having common areas. 2. When the outdoor fighting consists of only one (1) luminaire. 3. Code required lighting for steps, stairs, walkways, and building entrances. 4. When in the opinion of the community development director, lighting levels must be maintained. 5. Motion activated lighting. 6. Lighting governed by special use permit in which times of operation are specifically identified. 7. Lighting used to illuminate potential obstructions and/or hazards to air navigation.

(Ord. No. 2023-25, § 1(Exh. A), 11-6-23)

Ask a question about Surprise law

Corpus searches the Surprise sections it holds and shows the ones that match, with their citations. Free, no sign-in.