Sec. 58-306. - Interceptors.

(a) Required. Users shall install interceptors to address discharges of grease, oil, sand, and other substances that impact wastewater treatment plants. Interceptors are necessary for the proper handling of liquid wastes containing grease or oil in excessive amounts or any flammable wastes, sand, and other harmful ingredients. (1) Except that such interceptors shall not be required for private living quarters or dwelling units unless the residential unit is used for business purposes such as a nursing care facility or group home. (b) Type, capacity and location. All interceptors shall conform to current city requirements and standards and shall be located, at all times, so as to be readily and easily accessible for cleaning and inspection. (c) Users shall install, in compliance with this article, lint traps, grease interceptors, and sand/oil separators. (d) Businesses or activities that shall be required to have an interceptor shall include: (1) Significant industrial users (SIU); (2) Non-significant categorical industrial users; and (3) Commercial users, including, but not limited to, assisted living facility; automotive repair and maintenance shop; carwashes; facilities with a clothes washer; drycleaning and laundry services; facilities with an emergency floor drain; food service establishments; garages and service stations; group homes; hair, nail, and skin care services; nursing care facilities; offices of dentists; pet and pet supply retailers that provide grooming services; photofinishing laboratories; residential setting care facilities. (e) Grease and oil interceptors. (1) All interceptors, separators, and traps shall be constructed using impervious materials capable of withstanding abrupt and extreme changes in temperature, as well as a pH of three and a pH of nine or higher, using substantial watertight construction, and equipped with easily removable covers, and with gastight and watertight bolted covers, when required. (2) All interceptors, separators, and traps shall be of the type and capacity approved by water resource management and shall be located so as to be easily accessible for cleaning and inspection. The user shall, at the user's expense, regularly inspect, clean, and repair all interceptors, separators, and traps to ensure their continuous, efficient operation at all times. The user shall keep for at least three years, on the site where the interceptor, separator, or trap is located, written records of all cleaning, repair, calibration, and maintenance, and such records shall be available for inspection by the water utilities compliance manager, or designee, upon request. (3) In accordance with the American Standards of Plumbing and Engineering (ASPE) Design Handbook Volume 2, Plumbing and Drainage Institute (PDI-G101), and International Plumbing Code (IPC, Chapter 10, Section 1003.3.5), the minimum size for all interceptors shall be a capacity of 500 gallons, and the maximum size for all interceptors shall be a capacity of 2,500 gallons. The appropriate size for interceptors and traps shall be determined according to the methodology outlined in the forementioned documents. (4) After approved by the city for installation, all interceptors shall be made from materials which are not subject to corrosion. If the interceptor is lined or coated with a durable material then the lining or coating shall be compatible with a pH of three and shall not be easily penetrated, scraped away, or removed. Acid Resistant Enamel (A.R.E.) coatings shall not be used. (5) Requirements for interceptors. Interceptors shall: a. Have a minimum 500-gallon capacity, two chamber concrete container (fiber glass and/or other type of material that must be approved by the water utilities manager); b. When calculated to have a capacity of 750 gallons or more, have three chambers, each with a manway; c. Be constructed with inlet piping with a 90 degree elbow and minimum 18-inch down spout; d. Be constructed with outlet piping with a tee connection and a threaded cover with a minimum 18-inch down spout; e. Be installed with a two-way clean-out within five feet before and five feet after the interceptor; and f. Be constructed with the appropriate traffic rated cover. (f) Grease traps. The city may permit grease traps when there are four or fewer fixtures used for food preparation. In the context of sizing a grease trap, a fixture means the entire unit, e.g., a three-compartment sink shall be considered one unit. All users must install a grease trap as follows: (1) A grease trap shall be installed whenever a three-compartment sink is used. (2) The minimum size grease trap to be installed shall be rated no smaller than 50 gallons per minute with a 100-pound grease capacity. (3) If the grease trap is placed below floor level, a flow restriction valve must be installed in a manner that allows for inspection and maintenance upstream of the grease trap and shall be vented. (4) Except for domestic wastewater, users shall not install or replace equipment designed to convert garbage or solid waste into liquefied waste and introduce such waste into the POTW by means of a garbage grinder/disposal. Users shall dispose of garbage and solid waste as solid waste. (5) The city may require users with the potential to discharge flammable substances to install and maintain a city-approved combustible gas detection meter. (6) All facilities installing a dishwasher shall install a grease interceptor.

(Ord. No. 2012-06, § 1, 5-8-2012; Ord. No. 2026-03, § 1(Exh. A), 1-20-26)

Ask a question about Surprise law

Corpus searches the Surprise sections it holds and shows the ones that match, with their citations. Free, no sign-in.