For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-600 — Adopted; where filed; amendments

The Code of the City of Tempe, Arizona (Supp. No. 34, Update 1: codified through Ordinance No. O2026.34, enacted June 25, 2026) · Tempe City Code § 8-600

Corpus is an independent public-information project, not the official City of Tempe website. Stable reference: corpuslaw.us/code/3175de4f-40a1-4c0a-84df-71c20669b1c9

Sec. 8-600. - Adopted; where filed; amendments.

That certain document known as "The International Plumbing Code, 2024 Edition," which has been published as a code in book form by the International Code Council (ICC), chapters one through fifteen and, appendix chapters B, C, and E inclusive, three (3) copies with amendments of which are on file in the office of the City Clerk, and this same code, appendix and amendments are hereby referred to, adopted and made a part hereof, as if fully set forth in this article. Chapter 1 Scope and Administration Notes: 1. For reserved sections herein, refer to the City of Tempe Administrative Code for these code requirements. 2. Any conflicts between this code and the Tempe Administrative Code, the Tempe Administrative Code shall apply. 101.1 Title. These regulations shall be known as the International Plumbing Code as amended by the City of Tempe hereinafter referred to as "this code or IPC". These regulations are one document of the overall City of Tempe Construction Code as defined by the adopting ordinance. 101.2.1 Appendices. Provisions in the appendices shall not apply unless specifically adopted. Appendices B, C, & E are adopted in this code. 101.4 Severability. - Reserved. 102.1 General. - Reserved. 102.8 Referenced codes and standards. - Reserved 102.8.1 Conflicts. - Reserved. 102.8.2 Provisions in referenced codes and standards. - Reserved. 102.10 Other laws. - Reserved. 102.11 Application of references. - Reserved. Section 103 Code compliance agency - Reserved. Section 104 Duties and powers of the code official - Reserved. Section 105 Permits - Reserved. Section 106 Construction documents - Reserved. Section 107 Notice of approval - Reserved. Section 108 Fees - Reserved. Section 109 Service utilities - Reserved. Section 110 Temporary uses, equipment and systems - Reserved. Section 112 Means of appeals - Reserved. Section 113 Board of appeals - Reserved. Section 114 Violations - Reserved. Section 115 Stop work order - Reserved. Section 111.3 and 111.3.2. Section 111 Inspections and Testing. 111.3 Special inspections. Special inspections of alternative engineered design plumbing systems shall be conducted in accordance with Sections 111.3.1 and 111.3.2 and chapter 17 of the International Building Code as adopted. 111.3.2 Written report. The registered design professional shall submit a final report and the completed special inspection certificate in writing to the code official upon completion of the installation, certifying that the alternative engineered design conforms to the approved construction documents and that all special inspections have been conducted. A notice of approval for the plumbing system shall not be issued until a written certification has been submitted. Section 312.1.1. 312.1.1 Test gauges. Gauges used for testing shall be as follows: 1. Tests requiring a pressure of 10 psi (69 kPa) or less shall utilize a testing gauge having increments of 0.10 psi (0.69 kPa) or less. 2. Tests requiring a pressure of greater than 10 psi (69 kPa) but less than or equal to 100 psi (689 kPa) shall utilize a testing gauge having increments of 1 psi (6.9 kPa) or less. 3. Tests requiring a pressure of greater than 100 psi (689 kPa) shall utilize a testing gauge having increments of 2 psi (14 kPa) or less. 4. Pressure tests required by this code, which are performed utilizing dial gauges, shall be limited to a gauge having a maximum gauge rating not exceeding twice the applied test pressure. Section 317.1. 317.1 Plumbing special inspections and observations. The owner or the owner's authorized agent, other than the contractor, shall employ the registered design professional responsible for the plumbing design or one or more approved agencies designated by the registered design professional responsible for the plumbing design to perform visual observations of complex plumbing equipment and systems for general conformance to the approved plans and specification, including but not limited to, placement and interconnection of equipment and shall identify the approved agencies to the building official in accordance with Section 1704.2 of the International Building Code as amended. Plumbing observations shall be performed at significant stages of the construction and when the installation is complete and ready for inspection. Plumbing observations are in addition to and not in lieu of inspections required by the Tempe Administrative Code, Section 110, and Section 1705.12.6 of the International Building Code, and shall be provided when one of the following conditions exist: 1. Alternative engineered design plumbing systems as allowed by Section 316 of this code. 2. Computer designed drainage and vacuum drainage systems as allowed Sections 713 and 715 of this code. 3. Medical gas and vacuum systems as allowed by Section 1202 of this code. 4. Non-medical oxygen systems as allowed by the Section 1203 of this code. 5. Non-potable water systems as allowed Chapters 13 and 14 of this code. 6. Special cases - Work which, in the opinion of the building official, involves unusual hazards or conditions. Section 403.2. 403.2 Separate facilities. Where plumbing fixtures are required, separate toilet facilities shall be provided for each sex. Exceptions: 1. Separate toilet facilities shall not be required for dwelling units and sleeping units. 2. Separate toilet facilities shall not be required in structures or tenant spaces with a total occupant load, including both employees and customers, of 30 or fewer. 3. Separate toilet facilities shall not be required in mercantile occupancies in which the maximum occupant load is 30 or fewer. 4. Separate toilet facilities shall not be required in business occupancies in which the maximum occupant load is 30 or fewer. 5. Separate toilet facilities shall not be required to be designated by sex where single- user toilet rooms are provided in accordance with Section 403.1.2. 6. Separate toilet facilities shall not be required where rooms having both water closets and lavatory fixtures are designed for use by all persons regardless of sex and privacy is provided for water closets in accordance with Section 405.3.4 and for urinals in accordance with Section 405.3.5. Section 410.2. 410.2 Small occupancies. Drinking fountains shall not be required for an occupant load of 30 or fewer. Section 410.4, 416.3. 410.4 Substitution. Occupancies that provide food and/or beverage service to patrons do not need to provide drinking fountains. In other occupancies, where drinking fountains are required, water dispensers, bottled water dispensers or bottled water, where free of charge, shall be permitted to be substituted for not more than 50 percent of the required number of drinking fountains. Section 416.3. 416.3 Commercial food waste disposer. Commercial food waste disposers are not allowed per the Public Works Director. Section 605.25. 605.25 Non-Metallic Potable Water Pipe, Fittings, and Valves. Non-Metallic potable water pipe, fittings, and valves shall not be exposed in exterior outdoor locations. Components of the exterior exposed potable water system shall be metallic only and approved metallic materials, fittings, and valves are listed in IPC Table 605.3, IPC Table 605.4, IPC Table 605.5, and IPC Table 605.6. 608.7.2 Secondary backflow protection. The following activities or facilities shall have a Secondary Reduced Pressure Principle Backflow Prevention assembly installed as close as practicable to each point of service delivery: Hospitals, surgical clinics, medical buildings, laboratories, morgues, mortuaries, veterinary hospitals, animal grooming shops, industrial occupancies, packing plants, slaughter houses, chemical plants, municipal waste treatment facilities, auxiliary water systems, construction water services or as otherwise required by the City of Tempe Building Official. Note: Multiple water services which are interconnected onsite shall be provided with not less than a Double Check Valve Assembly at each service connection. Section 608.8. 608.8 Valves and outlets prohibited below grade. Potable water outlets and combination stop-and-waste valves shall not be installed underground or below grade. A freezeproof yard hydrant that drains the riser into the ground shall be considered as having a stop-and-waste valve below grade. Exception: Freezeproof yard hydrants that drain the riser into the ground shall be permitted to be installed, provided that the potable water supply to such hydrants is protected in accordance with ASSE 1057 Freeze Resistant Sanitary Yard Hydrant with Backflow Protection, and the hydrants and the piping from the backflow preventer to the hydrant are identified in accordance with Section 608.9. 608.8.1 Prohibited Locations. Backflow prevention devices shall not be installed in pits, underground vaults, or submerged locations. Section 903.1.1. 903.1.1 Roof extension unprotected. Open vent pipes that extend through a roof shall be terminated not less than 6 inches (152 mm) above the roof. Section 1003.1, 1003.3. 1003.1 Where required. Interceptors and separators shall be provided to prevent the discharge of oil, grease, sand and other substances harmful or hazardous to the public sewer, the private sewage system or the sewage treatment plant or processes. The Public Works Director may require additional conditions when interceptors and separators are required. 1003.3 Grease interceptors. Grease interceptors shall comply with the requirements of Sections 1003.3.1 through 1003.3.8. The Public Works Director may provide additional requirements. Section 1106.1. 1106.1 General. The size of the vertical conductors and leaders, scuppers, building storm drains, building storm sewers and any horizontal branches of such drains or sewers shall be based on the 100-year hourly rainfall rate of three (3) inches (76 mm) per hour. Section 1109.1. 1109.1 General. All storm water related installations and alterations shall follow the currently adopted City of Tempe Storm Water Management Plan. Appendices B, C, and E Adopt Appendices B, C, & E.

(Ord. No. O2018.59, §§ 1, 7, 8-30-18; Ord. No. O2019.03, 2-28-19; Ord. No. O2024.19, § 12, 9-5-24; Ord. No. O2026.24, § 7(Exh. A), 6-4-26)

Ask a question about Tempe law

Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.