§ 8-500 — Adopted; where filed; amendments

The Code of the City of Tempe, Arizona (Supp. No. 34, Update 1: codified through Ordinance No. O2026.34, enacted June 25, 2026) · Tempe City Code § 8-500

Corpus is an independent public-information project, not the official City of Tempe website. Stable reference: corpuslaw.us/code/8b9693af-6d17-4095-8b9b-cd5fe9db7de9

Sec. 8-500. - Adopted; where filed; amendments.

That Certain document known as "The International Mechanical Code, 2024 Edition," which has been published as a code in book form by the International Code Council (ICC), chapters one through nine and chapters eleven, twelve, fourteen, fifteen and appendix chapter A inclusive, three (3) copies with amendments of which are on file in the office of the City Clerk, and this same code, appendix and amendments are hereby referred to, adopted and made a part hereof, as if fully set forth in this article. Chapter 1 Scope and Administration Notes: 5. For reserved sections herein, refer to the City of Tempe Administrative Code for these code requirements. 6. Any conflicts between this code and the Tempe Administrative Code, the Tempe Administrative Code shall apply. 101.1 Title. These regulations shall be known as the International Mechanical Code as amended by the City of Tempe hereinafter referred to as "this code or IMC". These regulations are one document of the overall City of Tempe Construction Code as defined by the adopting ordinance. 101.2 Appendices. Provisions in the appendices shall not apply unless specifically adopted. Appendix A is adopted. 101.4 Severability. - Reserved. 102.1 General. - Reserved. 102.8 Referenced codes and standards. - Reserved Exception: Where enforcement of a code provision would violate the conditions of the listing of the equipment or appliance, the conditions of the listing and the manufacturer's installation instructions shall apply. 102.8.1 Conflicts. - Reserved. 102.8.2 Provisions in referenced codes and standards. - Reserved. 102.10 Other laws. - Reserved. 102.11 Application of references. - Reserved. Section 103 Code compliance agency - Reserved. Section 104 Duties and powers of the code official - Reserved. Section 105 Permits - Reserved. Section 106 Construction documents - Reserved. Section 107 Notice of approval - Reserved. Section 108 Fees - Reserved. Section 109 Service utilities - Reserved. Section 110 Temporary uses, equipment and systems - Reserved. Section 112 Means of appeals - Reserved. Section 113 Board of appeals - Reserved. Section 114 Violations - Reserved. Section 115 Stop work order - Reserved. Section 309.1. [BG] 309.1 Heating and cooling systems. Interior spaces intended for human occupancy shall be provided with active or passive heating and cooling systems capable of maintaining an indoor temperature between 70°F (21°C) and 82°F (28°C) (if cooled by air conditioning, and 88°F (31°C) if cooled by evaporative cooling). measured at a point 3 feet (914mm) above the floor in the center of the room. The installation of space heaters or coolers shall not be used to achieve compliance with this section. Exceptions: 2. Space heating and cooling systems are not required for interior spaces where the primary purpose is not associated with human comfort. 2. Group F, H, S, and U occupancies. Section 313.1. 313.1 Mechanical special inspections and observations. The owner or the owner's authorized agent, other than the contractor, shall employ the registered design professional responsible for the mechanical design or one or more approved agencies designated by the registered design professional responsible for the mechanical design to perform visual observations of complex mechanical equipment and systems for general conformance to the approved plans and specification, including but not limited to, placement and interconnection of equipment and shall identify the approved agencies to the building official in accordance with Section 1704.2 of the International Building Code as amended. Mechanical observations shall be performed at significant stages of the construction when the installation is complete and ready for inspection. Mechanical observations are in addition to and not in lieu of inspections required by the Tempe Administrative Code, Section 110, and by Section 1705.12.6 of the International Building Code, and shall be provided when one of the following conditions exist: 1. Duct smoke detectors for air distribution systems as install in accordance with Section 606 of this code. 2. Fire, fire/smoke, radiation and smoke damper operation for dampers install in accordance with Section 607 of this code. 3. Installation of alternative grease duct enclosure systems including but not limited to grease duct-wrap or double wall grease duct systems, install in accordance with Sections 506.3.11.2and 506.3.11.3 of this code. 4. The welding of grease duct joints, seams penetrations, and duct-to-hood joints required by Section 506.3.2 and 506.3.2.2 of this code. 5. The required grease duct leakage test required by Section 506.3.2.5 of this code. 6. Type I hood performance test and the capture and containment test required by Section 507.6 and 507.6.1 of this code. 7. Test and Balance report for air balance of ventilation systems installed in ambulatory care and I-2 occupancies designed and installed in accordance with ASHRAE 170 as required by Section 407.1 of this code. 8. Hazardous exhaust systems install in accordance with Section 510 of this code. 9. Smoke control systems in accordance with Section 513 of this code. 10. Special cases - Work which, in the opinion of the building official, involves unusual hazards or conditions. Section 407.1. 407.1 General. Mechanical ventilation for ambulatory care facilities and Group I-2 occupancies shall be designed and installed in accordance with this code and ASHRAE 170. 407.1.1 Special Inspection. Mechanical systems designed and installed in accordance with IMC 407.1 and ASHRAE 170 shall be verified by a qualified third party Special Inspector. The Special Inspector/testing agency shall be an independent third party individual or firm and shall not be the installing contractor. A report shall be generated by the third party individual or firm showing compliance. Special inspections shall be as specified in Chapter 17 of the International Building Code as amended. Section 408.1. 408.1 General. Any building or portion thereof used to cultivate, produce, process, infuse or dispense marijuana shall be designed such that no emissions of dust, fumes, vapors or odors are introduced into the environment from the building or portion thereof. A ventilation system shall be designed to prevent the distribution of odors to other occupied spaces in the building or adjacent properties. Design of the odor control system shall be based on acceptable engineering practices. All equipment and filter media shall be listed and labeled for the application. Exhaust systems used in odor control systems shall meet the requirements of Section 501 of this code. Section 408.1.1. 408.1.1 Exhaust outlets. The termination point of exhaust outlets shall be in accordance with Section 501.3 of this code. Exhaust from cultivation and production facilities shall be in accordance with Section 501.3.1(2) of this code and for dispensaries in accordance with Section 501.3.1(3) of this code. Section 502.14. 502.14 Motor vehicle operation. In areas where motor vehicles operate, mechanical ventilation shall be provided in accordance with Section 403 Additionally, areas in which stationary motor vehicles are operated shall be provided with a source capture system that connects directly to the motor vehicle exhaust systems. Makeup air for the required exhaust systems in areas where motor vehicles operate shall be provided through permanent unobstructed openings to the outdoors, such as louvers and grills. Mechanical equipment and louvers used for makeup air purposes shall be electrically interlocked with the exhaust system. Such system shall be engineered by a registered design professional or shall be factory-built equipment designed and sized for the purpose. Exceptions: 1. This section shall not apply where the motor vehicles being operated or repaired are electrically powered. 2. This section shall not apply to one- and two-family dwellings. 3. This section shall not apply to motor vehicle service areas where engines are operated inside the building only for the duration necessary to move the motor vehicles in and out of the building. Section 606.2.1. 606.2 Where required. Smoke detectors shall be installed where indicated in Sections 606.2.1 through 606.2.3. Exception: Smoke detectors shall not be required where air distribution systems are incapable of spreading smoke beyond the enclosing walls, floors and ceilings of the room or space in which the smoke is generated. 606.2.1 Air distribution systems. Smoke detectors shall be installed in air distribution systems downstream of the filters and ahead of any branch connections in systems having a design capacity greater than 2,000 cfm (0.9 m3/s). Exception: Smoke detectors are not required where all portions of the building served by the air distribution system are protected by area smoke detectors connected to a fire alarm system in accordance with the International Fire Code. The area smoke detection system shall comply with Section 606.4. Section 608.1. 608.1 Balancing. Air distribution, ventilation and exhaust systems shall be provided with means to adjust the system to achieve the design airflow rates and shall be balanced by an approved method. Ventilation air distribution shall be balanced by an approved method and such balancing shall verify that the air distribution system is capable of supplying and exhausting the airflow rates required by Chapter 4. The ventilation air distribution system shall be provided with means to adjust the system to achieve not less than the minimum ventilation airflow rate as required by sections 403.3 and 403.3.1.2. Ventilation systems shall be balanced using a nationally accepted air balancing test method. Such balancing shall verify that the ventilation system is capable of supplying and exhausting the airflow rates required by Sections 403.3 and 403.3.1.2. A final report shall be provided to the engineer of record and the Tempe Building Inspector. Section 928.1. 928.1 General. Evaporative cooling equipment shall: 1. Be installed in accordance with the manufacturer's instructions. 2. Be installed on level platforms in accordance with Section 304.10. 3. Have openings in exterior walls or roofs flashed in accordance with the International Building Code. 4. Be provided with an approved water supply, sized for peak demand. The quality of water shall be provided in accordance with the equipment manufacturer's recommendations. The piping system and protection of the potable water supply system shall be installed as required by the International Plumbing Code. 5. Have air intake opening locations in accordance with Section 401.4. 6. A permanent relief opening or other engineered design sufficient to assure positive airflow shall balance intake air. 7. Outside air shall be provided as specified in Section 403.2. 8. Air ducts and dampers, which are a portion of an evaporative cooling system, shall comply with Chapter 6. 9. Overflow drains shall be provided that discharge to an approved disposal location. Section 932.1. 932.1 General. On or after December 31, 1998, no person, firm, or corporation shall construct or install a fireplace or a woodstove, and the city shall not approve or issue a permit to construct or install a fireplace or a woodstove, unless the fireplace or woodstove complies with one of the following: 1. A fireplace which has permanently installed gas or electric log insert; 2. A fireplace, woodstove, or other solid-fuel-burning appliance which has been certified by the United States Environmental Protection Agency as conforming to 40 Code of Federal Regulations Part 60, Subpart AAA; 3. A fireplace, woodstove, or other solid-fuel-burning appliance that has been tested and listed by a nationally recognized testing agency to meet performance standards equivalent to those adopted by 40 Code of Federal Regulations Part 60, Subpart AAA; 4. A fireplace, woodstove, or other solid-fuel-burning appliance that has been determined by the Maricopa County Air Pollution Control Officer to meet performance standards equivalent to those adopted by 40 Code of Federal Regulations Part 60, Subpart AAA; or 5. A fireplace that has a permanently installed woodstove insert that complies with paragraphs 2, 3, or 4 above. Exception: The following installations are not regulated and are not prohibited by this section: 1. Furnaces, boilers, incinerators, kilns, and other similar space heating or industrial process equipment; 2. Cook stoves, barbecue grills, and similar appliances designed primarily for cooking; and 3. Fire pits, barbecue grills, and other outdoor fireplaces. Fireplaces constructed or installed on or after December 31, 1998, that contain a gas or electric log insert or a woodstove insert, shall not be altered to directly burn wood or any other solid fuel. On or after December 31, 1998, no person, firm, or corporation shall alter a fireplace, woodstove, or other solid-fuel-burning appliance in any manner that would void its certification or operational compliance with the provisions of this section. Fireplaces constructed or installed on or after December 31, 1998, shall not be altered without first obtaining a permit from the city to ensure compliance with this section. Section 1001.1. 1001.1 Scope. This chapter shall govern the installation, alteration and repair of boilers, water heaters and pressure vessels, except where regulated by the Industrial Commission of Arizona. Section 1105.10. 1105.10 Dimensions. Refrigeration machinery rooms shall be of such dimensions that all system parts are readily accessible with adequate space for service, maintenance, and operations. A minimum unobstructed walking space at least three (3) feet (914 mm) in width and six (6) feet eight (8) inches (2032 mm) in height or approved manufacturer's installation or required clearances shall be maintained throughout, allowing free access to at least two sides of all moving machinery and approaching each stop valve. Access to refrigeration machinery rooms shall be restricted to authorized personnel and posted with permanent signage. Section 1109.2.5. 1109.2.5 Refrigerant pipe shafts. Refrigerant piping that penetrates two or more floor/ceiling assemblies shall be enclosed in a fire-resistance-rated shaft enclosure. The fire-resistance-rated shaft enclosure shall comply with Section 713 of the International Building Code. Exceptions: 1. Refrigeration systems using R-718 refrigerant (water). 2. Piping in a direct refrigeration system where the refrigerant quantity does not exceed the limits of Table 1103.1 for the smallest occupied space through which the piping passes. 3. Piping located on the exterior of the building where vented to the outdoors.

(Ord. No. O2018.59, §§ 1, 6, 8-30-18; Ord. No. O2026.24, § 6(Exh. A), 6-4-26)

Ask a question about Tempe law

Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.