For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-900 — Adopted; where filed; amendments

The Code of the City of Tempe, Arizona (Supp. No. 34, Update 1: codified through Ordinance No. O2026.34, enacted June 25, 2026) · Tempe City Code § 8-900

Corpus is an independent public-information project, not the official City of Tempe website. Stable reference: corpuslaw.us/code/7a0c493d-5395-4790-a909-d1832f81762d

Sec. 8-900. - Adopted; where filed; amendments.

That certain document known as the "International Energy Conservation Code, 2024 Edition," which has been published as a code in book form by the International Code Council (ICC), chapters one through six and appendix chapter CB for commercial provisions, and chapters one through six and appendix chapter RB for residential provisions, three (3) copies with amendments of which are on file in the office of the City Clerk, and this same code, and amendments are hereby referred to, adopted and made a part hereof, as if fully set forth in this article. Chapter 1 [CE] Chapter 1 Scope and Administration Notes: 1. For reserved sections herein, refer to the City of Tempe Administrative Code for these code requirements. 2. Any conflicts between this code and the Tempe Administrative Code, the Tempe Administrative Code shall apply. C101.1 Title. This code shall be known as the International Energy Conservation Code as amended by the City of Tempe and shall be cited as such. It is referred to herein as "this code or the Energy Code". These regulations are one document of the overall Tempe Construction Code as defined by the adopting ordinance. C101.2 Scope. This code applies to the design and construction of buildings not covered by the scope of the IECC-Residential Provisions. Group R-2 when defined as a Commercial Building by section C202, shall have the option of complying under the Residential Provisions of the code, regardless of height. Once defined as such on the submittal documents, all components of the Residential Provisions shall be followed. C101.4 Compliance. Residential buildings shall meet the provisions of IECC - Residential Provisions. Commercial buildings shall meet the provisions of IECC - Commercial Provisions. Group R-2 when defined as a Commercial Building by section C202, shall have the option of complying under the Residential Provisions of the code, regardless of height. Once defined as such on the submittal documents, all components of the Residential Provisions shall be followed. Section C102 Applicability. - Reserved Section C103 Code Compliance Agency. - Reserved Section C104 Alternative Materials, Design and Methods of Construction and Equipment. - Reserved Section C105 Construction Documents. - Reserved Section C106 Fees. - Reserved Section C108 Notice of Approval. - Reserved Section C109 Means of Appeals - Reserved Section C110 Stop Work Order - Reserved Chapter 4 [CE], Section C401.2.1 C401.2.1 International Energy Conservation Code. Commercial buildings shall comply with one of the following: 1. Prescriptive Compliance. The Prescriptive Compliance option requires compliance with Sections C402 through C406 and Sections C408. Dwelling units and sleeping units in Group R-2 buildings shall be deemed to be in compliance with this chapter, provided that they comply with Section R406. 2. Simulated Building Performance. The Simulated Building Performance option requires compliance with Section C407. Exceptions: 1. Additions, alterations, repairs, and changes of occupancy to existing buildings complying with Chapter 5. 2. Compliance with the provisions of Section C408 is optional. Chapter 4 [CE], Section C405.12, C405.13, C405.14, and C405.15. This section shall be deleted in its entirety. Note: The corresponding requirements in ASHRAE 90.18.4.2 Automatic Receptacle Control is also deleted in its entirety. This section is deleted in its entirety. Note: The corresponding requirements in ASHRAE 90.18.4.3 Electrical Energy Monitoring is also deleted in its entirety. C405.14 Reserved This section is deleted in its entirety. Note: The corresponding requirements in ASHRAE 90.1 10.5.1 Renewable Energy Systems is also deleted in its entirety. Chapter 1 [RE] R101.1 Title. This code shall be known as the International Energy Conservation Code as amended by the City of Tempe and shall be cited as such. It is referred to herein as "this code or the Energy Code". These regulations are one document of the overall Tempe Construction Code as defined by the adopting ordinance. R101.2 Scope. This code applies to the design and construction of buildings not covered by the scope of the IECC-Residential Provisions. Group R-2 when defined as a Residential Building by section R202, shall have the option of complying under the Commercial Provisions of the code, regardless of height. Once defined as such on the submittal documents, all components of the Commercial Provisions shall be followed. R101.4 Compliance. Residential buildings shall meet the provisions of IECC—Residential Provisions. Commercial buildings shall meet the provisions of IECC—Commercial Provisions. Group R-2 when defined as a Residential Building by section R202, shall have the option of complying under the Commercial Provisions of the code, regardless of height. Once defined as such on the submittal documents, all components of the Commercial Provisions shall be followed. Section R102 Applicability. - Reserved Section R103 Code Compliance Agency. - Reserved Section R104 Alternative Materials, Design and Methods of Construction and Equipment. - Reserved Section R105 Construction Documents. - Reserved Section R106 Fees. - Reserved Section R108 Notice of Approval. - Reserved Section R109 Means of Appeals - Reserved Section R110 Stop Work Order - Reserved Chapter 4 [RE], Section 401.1 R401.1 Scope. This chapter applies to residential buildings. Exceptions: Exterior lighting requirements for footcandles levels that are required by the City of Tempe, Zoning and Development Code, are not regulated by this code. Chapter 4 [RE], Section 404.1.5 Chapter 4 [RE], Section 503.1.2 R503.1.2 Heating and cooling systems. New heating and cooling systems and ductwork that are part of the alteration shall comply with Section R403 and this section. Alterations to existing heating and cooling systems and ductwork shall comply with this section. Exception: 1. Where ductwork from an existing heating and cooling system is extended. 2. Where additions do not exceed 250 square feet and do not exceed the capacities of the existing system.

(Ord. No. O2018.59, §§ 1, 10, 8-30-18; Ord. No. O2026.24, § 10(Exh. A), 6-4-26)

Ask a question about Tempe law

Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.