§ 15.05.130 — Section 1905 amended—Modifications to ACI 318

Municipal Code of the City of Bakersfield, California (Bakersfield Municipal Code current through Ordinance 5223, passed August 26, 2026 (municipal.codes publication, scraped 2026-11-17)) · Bakersfield Municipal Code § 15.05.130

Corpus is an independent public-information project, not the official City of Bakersfield website. Stable reference: corpuslaw.us/code/28e3745c-32c8-4406-82bf-35a24ee3d9f2

15.05.130 Section 1905 amended—Modifications to ACI 318.

Subsection 1905.1.7 is amended to read as follows: 1905.1.7 ACI 318, Section 14.1.4. Delete ACI 318, Section 14.1.4, and replace with the following: 14.1.4 — Plain concrete in structures assigned to Seismic Design Category C, D, E or F. 14.1.4.1 — Structures assigned to Seismic Design Category C, D, E or F shall not have elements of structural plain concrete, except as follows: (a) Concrete used for fill with a minimum cement content of two (2) sacks of Portland cement per cubic yard. (b) Isolated footings of plain concrete supporting pedestals or columns are permitted, provided the projection of the footing beyond the face of the supported member does not exceed the footing thickness. (c) Plain concrete footings supporting walls are permitted provided the footings have at least two continuous longitudinal reinforcing bars. Bars shall not be smaller than No. 4 and shall have a total area of not less than 0.002 times the gross cross-sectional area of the footing. A minimum of one bar shall be provided at the top and bottom of the footing. Continuity of reinforcement shall be provided at corners and intersections. All concrete floor slabs poured on earth, for buildings of group R occupancies, including garage floor slabs, shall be reinforced with a welded wire fabric of 6 x 6-10/10 minimum weight or approved equal. Exceptions: In detached one- and two-family dwellings three stories or less in height and constructed with stud-bearing walls, plain concrete footings with at least two continuous longitudinal reinforcing bars not smaller than No. 4 are permitted to have a total area of less than 0.002 times the cross cross-sectional area of the footing.

Ask a question about Bakersfield law

Corpus searches the Bakersfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.