§ 15.05.160 — Section 2304—General construction requirements

Municipal Code of the City of Bakersfield, California (Bakersfield Municipal Code current through Ordinance 5223, passed August 26, 2026 (municipal.codes publication, scraped 2026-11-17)) · Bakersfield Municipal Code § 15.05.160

Corpus is an independent public-information project, not the official City of Bakersfield website. Stable reference: corpuslaw.us/code/998a21de-b957-43c8-99d3-c3e3ae0d721f

15.05.160 Section 2304—General construction requirements.

Subsection 2304.12.2.8 is amended to read as follows: 2304.12.2.8 Wood used in retaining walls and cribs. Wood installed in retaining or crib walls shall be preservative treated in accordance with AWPA U1 (Commodity Specifications A or F) for soil and fresh water use. Wood shall not be used in retaining or crib walls for structures assigned to Seismic Design Category D, E or F. Subsection 2308.10.8 is amended to read as follows: 2308.10.8 Braced wall line support. Braced wall lines shall be supported by continuous foundations. Exception: For structures with a maximum plan dimension not over 50 feet (15240 mm), continuous foundations are required at exterior walls only for structures not assigned to Seismic Design Category D, E or F.