For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.62.360 — Drainage and terracing

Municipal Code of the City of Daly City, California (Codified through Ordinance No. 1492, passed June 8, 2026 (Supp. No. 39)) · Daly City Municipal Code § 15.62.360

Corpus is an independent public-information project, not the official City of Daly City website. Stable reference: corpuslaw.us/code/8ad88c78-cac8-44d6-9e82-f6b91cc94493

15.62.360 - Drainage and terracing.

A. General. Unless otherwise indicated on the approved grading plan, drainage facilities and terracing shall conform to the provision of this section. B. Terrace. Terraces at least six feet in width shall be established at not more than thirty-foot vertical intervals on all cut or fill slopes to control surface drainage and debris except that where only one terrace is required, it shall be at mid-height. For cut or fill slopes greater than sixty feet and up to one hundred twenty feet in vertical height, one terrace at approximately mid-height shall be twelve feet in width. Terrace widths and spacing for cut and fill slopes greater than one hundred twenty feet in height shall be designed by the civil engineer and approved by the building official. Suitable access shall be provided to permit proper cleaning and maintenance. A single run of swale or ditch shall not collect runoff from a tributary area exceeding thirteen thousand five hundred square feet (projected) without discharging into a downdrain. C. Subsurface Drainage. Cut and fill slopes shall be provided with subsurface drainage as necessary for stability. D. Disposal. All drainage facilities shall be designed to carry waters to the nearest practicable drainageway approved by the city engineer and/or other appropriate jurisdiction as a safe place to deposit such waters. Erosions of ground in the area of discharge shall be prevented by installation of nonerosive downdrains or other devices. Building pads shall have a drainage gradient of two percent toward approved drainage facilities, unless waived by the city engineer. Exception: The gradient from the building pad may be one percent if all the following conditions exist throughout the permit area: 1. No proposed fills are greater than ten feet in maximum depth; 2. No proposed finish cut or fill slope faces have a vertical height in excess of ten feet; 3. No existing slope faces, which have a slope face steeper than ten horizontally to one vertically, have a vertical height in excess of ten feet. E. Interceptor Drains. Paved interceptor drains shall be installed along the top of all cut slopes where the tributary drainage area above slopes towards the cut and has a drainage path greater than forty feet measured horizontally. Interceptor drains shall be paved with a minimum of three inches of concrete or gunite and reinforced. They shall have a minimum depth of twelve inches and a minimum paved width of thirty inches measured horizontally across the drain. The slope of drain shall be approved by the city engineer.

(Ord. 1213 § 1 (part), 1995)

Ask a question about Daly City law

Corpus searches the Daly City sections it holds and shows the ones that match, with their citations. Free, no sign-in.