§ 17.41.070 — Water budget calculations
Municipal Code of the City of Daly City, California (Codified through Ordinance No. 1492, passed June 8, 2026 (Supp. No. 39)) · Daly City Municipal Code § 17.41.070
Corpus is an independent public-information project, not the official City of Daly City website. Stable reference: corpuslaw.us/code/ecf1b7d7-83e6-4d79-866d-1b5db93361e5
17.41.070 - Water budget calculations.
Project applicant may elect to complete a water budget calculation for the landscape project using the water efficient landscape worksheet in appendix B. Water budget calculations, if prepared, shall adhere to the following requirements: A. The plant factor used shall be from WUCOLS or from horticultural researchers with academic institutions or professional associations as approved by the California Department of Water Resources (DWR). The plant factor ranges from 0 to 0.1 for very low water using plants, 0.1 to 0.3 for low water use plants, from 0.4 to 0.6 for moderate water use plants, and from 0.7 to 1.0 for high water use plants. B. All water features shall be included in the high water use hydrozone and temporarily irrigated areas shall be included in the low water use hydrozone. C. All special landscape areas (SLA) shall be identified and their water use included in the water budget calculations. D. The reference evapotranspiration adjustment factor (ETAF) for SLA shall not exceed 1.0. The ETAF for all other landscaped areas shall not exceed 0.55 for residential areas and 0.45 for non-residential areas. E. ETo values from the reference evapotranspiration table in appendix A shall be used in calculating the maximum applied water allowance (MAWA) and estimated total water use (ETWU). For geographic areas not covered in appendix A, use data from other cities located nearby in the same reference evapotranspiration zone, as found in the CIMIS Reference Evapotranspiration Zones Map, Department of Water Resources, 1999. For the purpose of determining estimated total water use, average irrigation efficiency is assumed to be 0.75 for overhead spray devices and 0.81 for drip system devices. F. MAWA shall be calculated using the equation below: MAWA = (ETo) (0.62) [(0.55 x LA) + (0.45 x SLA)] for residential areas MAWA = (ETo) (0.62) [(0.45 x LA) + (0.55 x SLA)] for non-residential areas Where: MAWA = Maximum applied water allowance (gallons per year) ETo = Reference evapotranspiration (inches per year) 0.62 = Conversion factor (to gallons) 0.55 = Reference evapotranspiration adjustment factor (ETAF) for residential areas 0.45 = Reference evapotranspiration adjustment factor (ETAF) for non-residential areas LA = Landscape area including SLA (square feet) 0.45 = Additional water allowance for SLA in residential areas 0.55 = Additional water allowance for SLA in non-residential areas SLA = Special landscape area (square feet) G. A local agency or project applicant may consider effective precipitation (twenty-five percent of annual precipitation) in tracking water use and may use the following equation to calculate the MAWA: 1. MAWA = (ETo - Eppt) (0.62) [(0.55 x LA) + (0.45 x SLA)] for residential areas. 2. MAWA = (ETo - EPPT) (0.62) [(0.45 x LA) + (0.55 x SLA)] for non-residential areas. H. Estimated total water use (ETWU) will be calculated using the equation below. The sum of the ETWU calculated for all hydrozones will not exceed the MAWA. [image omitted; see the official code] Where: ETWU = Estimated total water use per year (gallons) ETo = Reference evapotranspiration (inches) PF = Plant factor from WUCOLS (see Section 491 [California Code of Regulations]) HA = Hydrozone area [high, medium, and low water use areas] (square feet) 0.75 = Irrigation efficiency (IE) for overhead spray devices 0.81 = Irrigation efficiency (IE) for drip system devices SLA = Special landscape area (square feet) 0.62 = Conversion factor
(Ord. No. 1407, § 2, 2-22-2016)
Ask a question about Daly City law
Corpus searches the Daly City sections it holds and shows the ones that match, with their citations. Free, no sign-in.