For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.50.060 — Provisions for flood hazard reduction

Municipal Code, City of Elk Grove, California · Elk Grove Municipal Code § 16.50.060

Corpus is an independent public-information project, not the official City of Elk Grove website. Stable reference: corpuslaw.us/code/bd718885-3849-403e-a7ea-fed46db248e7

§ 16.50.060: Provisions for flood hazard reduction.

A. Standards of Construction. In all areas of special flood hazards, the following standards are required: 1. Anchoring. All new construction and substantial improvements of structures, including manufactured homes and tanks (e.g., water, propane), shall be adequately anchored to prevent flotation, collapse, or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. Permanent structures and caskets for burial located within cemeteries shall also meet this anchoring requirement. 2. Construction Materials and Methods. All new construction and substantial improvements of structures, including manufactured homes, shall be constructed: a. With flood-resistant materials, and utility equipment resistant to flood damage for areas below the base flood elevation; b. Using methods and practices that minimize flood damage. The use of aerial construction, including but not limited to stilts and piers, is prohibited; c. With electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; and d. Within Zone AH or AO, so that there are adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures. 3. Elevation and Flood-Proofing of Improvements to Existing Structures. The following shall apply to remodels of or improvements to existing structures already located within areas of special flood hazard. a. Residential Construction. When new square footage is proposed for an existing residential structure that is already constructed in an area of special flood hazard, the lowest floor, including basement, of the new square footage shall be in conformance with the following standards. Upon the completion of the new square footage, the elevation of the new floor, including basement, shall be certified by a registered civil engineer or licensed land surveyor to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator. i. In AE and AH, elevated to two (2' 0”) feet above the base flood elevation (BFE). ii. In an AO Zone, elevated above the highest adjacent grade to a height equal to or exceeding the depth number specified in feet on the FIRM, or elevated at least two (2' 0”) feet above the highest adjacent grade if no depth number is specified. iii. In an A Zone, without BFEs specified on the FIRM, elevated to or above the base flood elevation, as determined under EGMC Section 16.50.030(B)(4) (Review, Use, and Development of Other Base Flood Data). b. Nonresidential Construction. When new square footage is proposed for an existing non-residential structure (commercial, office, or industrial development) that is already constructed in an area of special flood hazard, all new improvements shall either be elevated to conform with subsection (A)(3)(a) of this section (Residential Construction); or i. Be flood-proofed, together with attendant utility and sanitary facilities, below the elevation recommended under subsection (A)(3)(a) of this section, so that the structure is watertight with walls substantially impermeable to the passage of water; ii. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and iii. Be certified by a registered civil engineer or architect that the standards of subsections (A)(3)(b)(i) and (ii) of this section are satisfied. Such certification will be provided to the Floodplain Administrator. c. Flood Openings. All new construction and substantial improvements of structures with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access, or storage, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement must meet the following minimum criteria: i. For non-engineered openings: (A) Have a minimum of two (2) openings on different sides having a total net area of not less than one (1 in2) square inch for every one (1 ft2) square foot of enclosed area subject to flooding; (B) The bottom of all openings shall be no higher than one (1') foot above grade; (C) Openings may be equipped with screens, louvers, valves, or other coverings or devices; provided, that they permit the automatic entry and exit of floodwater; and (D) Buildings with more than one (1) enclosed area must have openings on exterior walls for each area to allow floodwater to directly enter; or ii. Be certified by a registered civil engineer or architect. 4. New Non-Habitable Accessory Structures. a. Attached Garages. i. A garage attached to a residential structure, constructed with the garage floor slab below the BFE, must be designed to allow for the automatic entry of floodwaters. See subsection (A)(3)(c) of this section (Flood Openings). Areas of the garage below the BFE must be constructed with flood-resistant materials. See subsection (A)(2) of this section (Construction Materials and Methods). ii. A garage attached to a nonresidential structure must meet the above requirements or be dry flood-proofed. For guidance on below-grade parking areas, see FEMA Technical Bulletin TB-6. b. Detached Garages and Small Accessory Buildings. An accessory structure used solely for parking or other types of small accessory buildings, as defined in EGMC Section 16.50.020 (Definitions), may be constructed such that its floor is below the base flood elevation (BFE), provided the structure is designed and constructed in accordance with the following requirements: i. Use of the accessory structure must be limited to parking or limited storage; ii. The portions of the accessory structure located below the BFE must be built using flood-resistant materials; iii. The accessory structure must be adequately anchored to prevent flotation, collapse, and lateral movement; iv. Any mechanical and utility equipment in the accessory structure must be elevated or flood-proofed to or above the BFE; v. No hazardous materials shall be stored within the structure; vi. The accessory structure must comply with floodplain encroachment provisions in subsection (D) of this section (Floodways); vii. The accessory structure must be designed to allow for the automatic entry of floodwaters in accordance with subsection (A)(3)(c) of this section (Flood Openings); and viii. Detached garages and accessory structures not meeting the above standards must be constructed in accordance with all applicable standards in subsection (A) of this section (Standards of Construction). c. Other Accessory Structures. Other accessory structures, including but not limited to landscape features, pools and spas, patio covers, gazebos, tanks, and lean-tos, as defined in EGMC Section 23.100.020(A)(2) (Accessory Structure), may be constructed such that their floor is below the base flood elevation (BFE), provided the structure is designed and constructed in accordance with the following requirements: i. The structure cannot be permanently occupied; ii. The portions of the accessory structure located below the BFE must be built using flood-resistant materials; iii. The accessory structure must be adequately anchored to prevent flotation, collapse, and lateral movement; iv. Any mechanical and utility equipment in the accessory structure must be elevated or flood-proofed to or above the BFE; v. The accessory structure must comply with floodplain encroachment provisions in subsection (D) of this section (Floodways); vi. The accessory structure must be designed to allow for the automatic entry of floodwaters in accordance with subsection (A)(3)(c) of this section (Flood Openings). B. Standards for Utilities. 1. All new and replacement water supply and sanitary sewage systems shall be designed to minimize or eliminate: a. Infiltration of floodwaters into the systems; and b. Discharge from the systems into floodwaters. 2. On-site waste disposal systems shall be located to avoid impairment to them, or contamination from them, during flooding and all other Federal, State, and County requirements. Approval of these systems shall be provided prior to issuance of building permit for the main structure on the site. C. Standards for Subdivisions and Other Proposed New Development. 1. All new subdivision proposals and other proposed new development, including proposals for manufactured home parks and subdivisions/parcel maps, shall: a. Identify the special flood hazard areas (SFHAs), if necessary, and base flood elevations (BFEs). b. Identify the elevations of lowest floors of all proposed structures and pads on the final plans and/or elevation certificate certified from a registered civil engineer or architect. c. Provide a buildable area outside the area of special flood hazard of sufficient size to accommodate a residence and associated structures. d. In special flood hazard areas, elevate the lowest finished floor at least two (2’0”) feet above the base flood elevation. Building pads for slab-on-grade construction shall be at least one and one-half (1' 6") feet above the base flood elevation and the lowest finished floor shall be at least two (2' 0") feet above the base flood elevation. For critical infrastructures, such as nursing homes and hospitals, the lowest finished floor shall be at least three (3' 0") feet above the base flood elevation or the elevation corresponding to the five hundred (500) year floodplain, whichever is greater. e. In unmapped areas, elevate the lowest finished floor at least two (2' 0") feet above the base flood elevation. Building pads for slab-on-grade construction shall be at least two (2' 0") feet above the base flood elevation and the lowest finished floor shall be at least two (2' 0") feet above the BFE. f. In a SFHA, if the proposed site is to be elevated above the BFE by placement of fill, an application for a conditional letter of map revision, based on fill (CLOMR-F), shall be submitted to FEMA. 2. All subdivision proposals and other proposed development shall be consistent with the need to minimize flood damage. 3. All subdivision proposals and other proposed development shall have public utilities and facilities such as sewer, gas, electrical, and water systems located and constructed to minimize flood damage. 4. All subdivisions and other proposed development shall provide adequate drainage to reduce exposure to flood hazards. 5. Vehicular access to the buildable area(s) of the proposed development shall be at or above the ten (10) year flood elevation. 6. While the use of fill to create buildable area is strongly discouraged by City policy, should it be allowed, there shall be no net increase to the water surface elevation adjacent to, downstream, and upstream of the development, as determined by the City. Other improvements may be required as part of the proposed project. A conditional letter of map revision (CLOMR) issued by FEMA shall be required prior to grading permit issuance, unless only a LOMR is required. A letter of map revision (LOMR) issued by FEMA shall be required prior to acceptance of the improvements or issuance of the first (1st) building permit as determined by the Floodplain Administrator. D. Floodways. Since floodways are an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles, and erosion potential, the following additional provisions apply: 1. Until a regulatory floodway is adopted by FEMA, no new construction, substantial development, or other development (including fill) shall be permitted within Zones A, AE and AH, unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other development, will not increase the water surface elevation of the base flood at any point within the City. 2. Within an adopted regulatory floodway, the City shall prohibit encroachments, including fill, new construction, substantial improvements, and other development, unless certification by a registered civil engineer is provided demonstrating that the proposed encroachment shall not result in any increase in flood levels during the occurrence of the base flood discharge. 3. Notwithstanding subsections (D)(1) and (D)(2) of this section, the Floodplain Administrator may permit the approval of bridges, trails, drainage, and incidental non-habitable maintenance facilities if the Floodplain Administrator determines that such improvements that involve no more than one-tenth (0.1) of a foot increase in the water surface elevation when the one hundred (100) year event floodwaters are fully contained within open space or other approved undeveloped areas that are protected with a floodplain easement or other protection instrument and the physical and/or economic use of upstream and downstream property will not be adversely affected.

( Ord. 15-2016 § 5 (Exh. C), eff. 9-23-2016 ; Ord. 14-2017 § 3 (Exh. A), eff. 6-23-2017 ; Ord. 3-2025 § 3 (Exh. A), eff. 3-14-2025 ; Ord. 13-2025 § 3 (Exh. C), eff. 7-25-2025 )

Ask a question about Elk Grove law

Corpus searches the Elk Grove sections it holds and shows the ones that match, with their citations. Free, no sign-in.