§ 13.08.040 — Backflow prevention devices

Municipal Code of the City of El Monte, California (Codified through Ordinance No. 3055, passed June 11, 2025. (Supp. No. 36, Update 1)) · El Monte Municipal Code § 13.08.040

Corpus is an independent public-information project, not the official City of El Monte website. Stable reference: corpuslaw.us/code/7688276c-07f7-4ae1-99e0-d500a587adc6

13.08.040 - Backflow prevention devices.

A. Approved Backflow Prevention Devices. Only backflow prevention devices which have passed laboratory and field evaluation tests performed by a recognized testing organization which has demonstrated their competency to perform such tests to the Health Agency shall be acceptable for installation by a water user connected to the Water Company's potable public water system. B. Backflow Prevention Device Installation. Backflow prevention devices shall be installed in a manner prescribed in Section 7603, Title 17 of the California Code of Regulations. Location of the devices should be as close as practical to the user's connection. The Water Company shall have the final authority in determining the required location of a backflow prevention device. 1. Air-Gap Separation (AG). The air-gap separation shall be located on the user's side of and as close to the service connection as is practical. All piping from the service connection to the receiving tank shall be above grade and entirely visible. No water shall be provided from any point between the service connection and the air-gap separation. The water inlet piping shall terminate a distance of at least two (2) pipe diameters of the supply inlet, but in no case less than one inch above the flood rim of the receiving tank. 2. Reduced Pressure Principal Backflow Prevention Device (RP). The approved reduced pressure principle backflow prevention device shall be installed on the user's side of and as close to the service connection as is practical. The device shall be installed a minimum of twelve (12) inches above grade and not more than thirty-six (36) inches above grade measured from the bottom of the device and with a minimum of twelve (12) inches side clearance. The device shall be installed so that it is readily accessible for maintenance and testing. Water supplied from any point between the service connection and the RP device shall be protected in a manner approved by the Water Company. 3. Double Check Valve Assembly (DC). The approved double check valve assembly shall be located as close as practical to the user's connection and shall be installed above grade, if possible, and in a manner where it is readily accessible for testing and maintenance. If a double check valve assembly is put below grade it must be installed in a vault such that there is a minimum of six (6) inches between the bottom of the vault and the bottom of the device, so that the top of the device is no more than a maximum of eight (8) inches below grade, so there is a minimum of six (6) inches of clearance between the side of the device with the rest cocks and the side of the vault, and so there is a minimum of three (3) inches clearance between the other side of the device and the side of the vault. Special consideration must be given to double check valve assemblies of the "Y" type. These devices must be installed on their "side" with the test cocks in a vertical position so that either check valve may be removed for service without removing the device. Vaults which do not have an integrated bottom must be placed on a three (3) inch layer of gravel. C. Backflow Prevention Device Testing and Maintenance. 1. The owner of any premise on which or on account of which, approved backflow prevention devices are installed, shall have the devices tested by a person who has demonstrated his or her competency in testing of these devices. Backflow prevention devices must be tested at least annually and immediately after installation, relocation or repair. The Water Company may require a more frequent testing schedule if it is determined to be necessary. No device shall be placed back in service unless it is functioning as required. A report in a form acceptable to the Water Company shall be filed with the Water Company each time a device is tested, relocated, or repaired. These devices shall be serviced, overhauled, or replaced whenever they are found to be defective and all costs of testing, repair and maintenance shall be borne by the water user. 2. Persons competent to test backflow prevention devices are those persons certified as backflow prevention assembly testers by the county of Los Angeles Department of Health Services, or the American Water Works Association. The Water Company will notify affected water users by mail when annual testing of a device is needed and shall also provide water users with the necessary forms which must be filled out each time a device is tested or repaired. D. Backflow Prevention Device Removal. Approval must be obtained from the Water Company before a backflow prevention device is removed, relocated, or replaced. 1. Removal. The use of a device may be discontinued and the device removed from service upon presentation of sufficient evidence to the Water Company to verify that a hazard no longer exists or is not likely to be created in the future. 2. Relocation. A device may be relocated following confirmation by the Water Company that the relocation will continue to provide the required protection and satisfy installation requirements. A retest will be required following the relocation of the device. 3. Repair. A device may be removed for repair, provided the water use is either discontinued until repair is completed and the device is returned to service, or their service connection is equipped with other backflow protection approved by the Water Company. A retest will be required following the repair of the device. 4. Replacement. A device may be removed and replaced provided the water use is discontinued until the replacement device is installed. All replacement devices must be approved by the Water Company and must be commensurate with the degree of hazard involved.

(Prior code § 7453)

Ask a question about El Monte law

Corpus searches the El Monte sections it holds and shows the ones that match, with their citations. Free, no sign-in.