§ 17.134.070 — Design guidelines
Municipal Code of the City of El Monte, California (Codified through Ordinance No. 3055, passed June 11, 2025. (Supp. No. 36, Update 1)) · El Monte Municipal Code § 17.134.070
Corpus is an independent public-information project, not the official City of El Monte website. Stable reference: corpuslaw.us/code/281cb3c4-677c-4ff9-a704-efc6575156d2
17.134.070 - Design guidelines.
A. Historic Compatibility. When a new development or rehabilitation of an existing is adjacent to or in the immediate area of an historic property, the development or rehabilitation shall comply with Secretary of Interior's Standards and Guidelines for the Treatment of Historic Properties. In addition, it shall be consistent with the following design guidelines for historic compatibility: 1. Maintain historic features and elements of existing buildings. 2. Restore existing historic features that may have been altered from past remodels (e.g. remove a false façade on a building to reveal its original brick exterior). 3. New construction should respect and complement the original period and style of adjacent buildings without mimicking them exactly. 4. New construction should avoid a false "historical" look. B. Sustainability. Sustainability includes the protection and conservation of irreplaceable non-renewable resources. The transit-oriented nature of the Downtown Specific Plan is inherently sustainable as the intent is to connect nearby residential neighborhoods to transit facilities, services, shopping and dining establishments through a series of walkable streets and paseos. This will lead to a reduction in auto dependency, encourage an active lifestyle and add a sense of vibrancy to Main Street. 1. General Sustainable Design Guidelines. a. Residences should be within one-quarter mile or less from services, transit and other daily needs, and should be linked with strong pedestrian connections. b. Auto-dependency should be reduced by providing pedestrian linkages through walkways or bike paths. c. Public parks and plazas should provide well-linked active and passive open space for an opportunity for exercise and recreation. d. Buildings should be oriented to maximize active and/or passive solar gain; this allows the façades to let light in, reduce glare, and reduce overheating to the building interior. e. Architectural elements such as skylights and high-performance glazing should be used to conserve energy, where possible. f. Climatic factors such as prevailing winds shade trees, window and door orientation, and the positioning of buildings should be coordinated to maximize energy conservation. 2. Stormwater Management Design Guidelines. a. The project site should be designed to maintain natural stormwater flows by promoting infiltration. b. Impervious surfaces should be minimized. c. Site drainage should be designed to integrate a decentralized system that distributes stormwater across a project site. d. Various devices should be considered that filter water and infiltrate water into the ground. e. For areas with poor drainage conditions, the provision of drainage chimneys/wells, subsurface water storage or the provision of bioswales to clean the water and transfer off-site should be provided. f. Practices to control pollution should be incorporated. Examples include phased construction, seeding, non-invasive grading, mulching, filter socks, stabilized site entrances, sediment controls, fiber rolls and stabilized channels and outlets. 3. Existing Building Reuse Design Guidelines. a. The reuse of existing structures should be considered. The energy required to reuse a structure is potentially less than the energy required to develop a new structure. b. Reused buildings should incorporate new architectural elements in juxtaposition with old ones where appropriate. 4. Cool Roof and Green Roof Design Guidelines. Both cool roofs and/or green roofs should be considered for buildings. 5. Solar System Design Guidelines. a. Buildings should be designed to take advantage of solar orientation to ensure that windows, walls and floors are built to collect, store and distribute solar heat efficiently. b. New residential and non-residential buildings should have solar-ready roofs. c. Solar panels should be incorporated in parking lots. C. Site Design. The following guidelines are designed to enhance the overall site layout to achieve the pedestrian-oriented vision for the Downtown Specific Plan. 1. Buildings. Should be oriented toward the street and/or a publicly accessible space such as a plaza. 2. Focal Points. Should be developed at intersections, corners and the end of streets and pedestrian walkways to create a sense of identification. Plazas, landscape, fountains, artwork, textured pavement and vertical building features may be combined to create focal points. 3. Landscaping. a. Landscaping should be installed between the street and the sidewalk and/or trees planted in tree wells to buffer the sidewalk from traffic and to provide enhanced pedestrian areas. b. Landscaping within parking areas should be protected from encroaching vehicles by concrete curbing or raised planting areas. 4. Outdoor Spaces. a. Outdoor spaces should have a clear purpose that reflects careful planning and not simply "left over" areas between structures. Such spaces should be landscaped and/or provide pedestrian amenities, including benches, bicycle racks, fountains and/or public art and should be coordinate with the city as part of a development proposal. b. Communal Open Spaces (e.g. plazas, common green spaces) should be integrated within commercial areas and residential developments to provide places for residents and visitors to relax, play and interact. 5. Parking Areas. a. Parking lots should be provided behind buildings, subterranean or within parking structures, where possible. b. Parking areas should be landscaped to minimize glare and heat buildup and reduce negative visual impacts associated with large paving areas. c. Dead-end drive aisles should be avoided. d. The primary entry drive to parking lots, as well as pedestrian paths of travel within a parking lot, should be accented with enhanced paving and landscaping. Permeable or semi-permeable surfaces such as pavers are preferred for accent paving. 6. Loading and Delivery Areas. Should be located at the rear or side of buildings and should be screened with decorative walls, trellises/vines, berms with landscaping and/or trees. D. Pedestrian and Vehicular Connections. The circulation pattern throughout the Downtown Specific Plan will play a pivotal role in the success of attracting visitors and potential tenants to the downtown. It is important to establish a well-connected system of streets and paths, both internally and to surrounding uses, to allow users to choose from a variety of transportation modes including public transit, walking and biking. 1. Plazas and outdoor use areas should be enhanced with shade trees or shade structures and pedestrian amenities such as benches, fountains, landscaping and public art. 2. Pedestrian paths and paseos should be designed as integral circulation routes to foster a vibrant environment that encourages walking and enhances the pedestrian experience. 3. Access between transit stops and Main Street should be clearly defined. 4. Surfaces made from permeable materials such as pavers should be provided, where possible. 5. Outdoor furniture and fixtures should be compatible with the project's architecture and should be carefully considered as integral elements of the project. E. Building Form and Mass. Design building forms to create interesting architecture that relates to pedestrian scale, creates a downtown character, and minimizes the appearance of large box-like buildings. 1. Variation in wall and roof planes should be used on large monolithic structures to break up the boxlike appearance. Surface detailing, such as score lines, should not serve as a substitute for distinctive massing. 2. Building designs should incorporate three hundred sixty-degree architecture. Such architecture is full of articulation on every building elevation. This includes variation in massing, roof forms, and wall planes, as well as surface articulation. 3. Architectural elements that add visual interest, scale and character such as projecting balconies, trellises, recessed windows, window detailing and door detailing should be incorporated to create shadow patterns and help articulate façades and blank walls. 4. Building surfaces that face walkways should be effectively articulated to enhance the pedestrian experience. 5. Contrasting base materials and/or molding elements should be used to anchor the building to the ground plane. 6. Entries, display windows, awnings, arcades and outdoor eating areas should be provided to create inviting public spaces. 7. The visual impact of large monolithic structures should be minimized by creating a cluster of smaller buildings or the appearance of a series of smaller buildings. 8. Stairways should be designed as an integral part of the overall architecture of the building and not appear as tacked on. F. Roof Form and Mass. Roof forms should be used to distinguish various building forms, create an interesting roof-line, and help to break up the building massing. 1. Buildings with flat or low-pitched roofs should incorporate parapets or architectural elements to break up long horizontal rooflines. 2. Deep roof overhangs are encouraged to create shadow and add depth to façades. Exposed structural elements (beams, rafter tails) are encouraged as roof overhang details. 3. Full roofs are desirable. Hipped or gable roofs covering the entire building are preferred to mansard roofs and segments of pitched roofs applied at the building edge. 4. Roof parapets should be well-detailed, be three (3) dimensional and of substantial size to complement the building. They should include one or more of the following detail treatments: pre-cast elements; continuous banding or projecting cornices; dentils; caps; corner details or variety in pitch (sculpted). 5. Parapets should be designed to avoid visibility of the interior. If the interior side of a parapet is visible from pedestrian view, it should be finished with the same materials and a similar level of detail as the front façade. 6. Parapets should not appear "tacked on" and should convey a sense of permanence. G. Windows, Doors and Entries. 1. Window, doors and entry design and materials should complement the desired architectural style of the building. 2. Entry design should incorporate two (2) or more of the following methods: a. Change in wall/window plane; b. A projecting element above the entrance; c. A change in material or detailing; d. Architectural elements and decorative fixtures; e. A portico or formal porch projecting from or set into the surface; f. Changes in the roofline or a tower; g. Front porch; and h. Decorative detailing or placement of art. 3. Where recessed entries occur, a decorative paving material, such as tile, marble or slate, is encouraged on the ground plane. 4. Windows should be articulated with accent trim, sills, shutters, window flower boxes, balconies, awnings or trellises authentic to the architectural style of the building. 5. Windows should be inset from building walls to create shade and shadow detail. 6. Faux shutters should be proportionate to the windows to create the appearance of a real and functional shutter. 7. Long, monotonous balconies and exterior corridors that provide access to multiple units should be avoided. Instead, access points should be clustered. H. Awnings. 1. All lots with more than one commercial occupant sharing contiguous frontage should maintain a common location and design for building awnings. 2. The bottom edge of awnings should be a minimum of eight (8) feet off the ground. 3. All awnings should be constructed with noncombustible materials such as a fireproof canvas or vinyl. 4. Awnings should be centered over doorways and windows. 5. Awnings should be in proportion to door and window openings. 6. Awnings should be of a color which is appropriate to the overall colors of the façade. 7. The shape, size, and number of awnings should be appropriate to the overall façade design and building size. 8. Awning structure should be sufficient to support safely the awning and withstand the pressures of wind and weather. 9. Awnings which become ripped, tattered, or damaged must be repaired or replaced within three (3) months of the occurrence/appearance of the damage. 10. Barrel awnings should not be permitted. I. Materials and Colors. 1. To convey a sense of high-quality design and permanence, building colors and materials should be selected to simulate authentic and timeless materials. 2. Contrasting colors are encouraged to accentuate details such as trim, windows, doors and key architectural elements, as long as selected colors reinforce the desired architecture style. 3. Fluorescent paints and bright colors are strongly discouraged. 4. Building base materials should be selected that are durable and highly resistant to pedestrian traffic such as pre-cast concrete, stone, masonry, brick, and commercial grade ceramic tile. 5. Recommended Façade Materials. a. Exterior plaster (smooth troweled preferred); b. Cut stone, rusticated block (cast stone), stone tile, and pre-cast concrete; c. Brick veneer, new or re-used; and d. Ceramic tiles. 6. Façade Materials That Are Discouraged. a. Imitation and crushed rock; b. Mirrored or reflective glass and heavily tinted glass; c. Windows with "tape on" divisions/mullions; d. Corrugated fiberglass; e. Vinyl and aluminum siding; f. Painted or baked enamel metal awnings; g. Rough "Spanish lace" stucco finish; h. Exposed concrete masonry units and split faced concrete masonry; i. Imitation brick; and j. Plywood siding. 7. Recommended Roof Materials. a. Roof tiles made of clay, slate, or integrally colored concrete; b. Roof tiles with "Mission" or "Barrel" shaped roof profiles; c. Metal roof panels with standing seam texture; and d. Ridge and hip caps and/or flashing should coordinate with field colors. 8. Roof Materials That Are Discouraged. a. Brightly colored material; b. Low-profile composition roof tile, wood and/or hard board, or synthetic shingles and shakes; c. Simulated clay tile roofs in metal; d. Corrugated metal roof panels; and e. Roof tiles with S-profile. J. Walls and Fencing/Screening. 1. Walls and fences should be designed with materials and finishes that complement the project's architecture and should be planted with vines, shrubs and/or trees. 2. All fences and walls required for screening purposes should be of solid material. Chain link or similar metal wire fencing with slats is prohibited for screening purposes. 3. A combination of low walls and landscaping should be used to screen unsightly elements of the project and define private and semi-private areas. 4. Fences and walls should be constructed as low as possible while still performing screening, noise attenuation and security functions. 5. Service areas are to be separate and screened from public areas by the use of walls and landscaping as much as possible. K. Lighting. 1. Light fixtures should be designed to relate in color, material, size, location and illumination with the building architecture. 2. All building entrances should be well-lit. 3. Exterior building lighting designated to illuminate signs should be mounted above the sign on the facade and should be appropriate to the size and scale of the signage. 4. Alley lighting, marking building entries, should be surface mounted and may be either flush with, recessed, or extended from the wall. No fluorescent lighting is allowed for this purpose. 5. Fluorescent lighting tubes shall be concealed by a shade or lens. 6. Parking lots, pedestrian walkways and paseos should be illuminated to ensure safe nighttime conditions. 7. Light fixtures should be sited, directed and/or shielded to prevent spot lighting, glare or light spillage beyond property lines. 8. The lighting of building elements and trees is an effective and attractive lighting technique that is encouraged; however, light sources for wall washing and tree lighting should be hidden and located so as to not shine in the eyes of pedestrians. 9. Low-voltage/high efficiency lighting should be used in the landscape. 10. Security lighting fixtures should not project above the fascia or roofline of the building and should not be substituted for parking lot or walkway lighting fixtures. 11. Timers and sensors should be incorporated to avoid unnecessary lighting in low volume pedestrian traffic areas. L. Refuse Enclosures. Carefully design, locate and integrate trash enclosures into the site plan. 1. Enclosures should be located away from adjacent residential uses to minimize nuisances to neighboring properties. 2. Self-clinging vines are encouraged to discourage graffiti. 3. Enclosures should be separated from adjacent parking stalls with a planter and paved surface behind the curb to provide easy access to a vehicle as well as adequate screening. 4. Refuse enclosures should be designed with similar finishes, materials and details as the primary building(s) within the project area. 5. Chain link or similar metal wire fencing with slats is prohibited. 6. Enclosures should be unobtrusive and conveniently located for refuse disposal by tenants and collection by service vehicles. 7. Where possible, a pedestrian entrance to the trash enclosure should be provided so that the large access doors do not have to be opened as frequently. M. Mechanical Equipment Screening. 1. Mechanical equipment on the ground should be completely screened from street level view with attractive planting, masonry walls, or iron fencing with planting which compliment building architecture. 2. All roof-mounted mechanical equipment should be located behind a permanent parapet wall and completely screened from ground level view. N. Parking Structures. Parking structures that seamlessly integrate with surrounding buildings are appropriate for Downtown El Monte. This can be accomplished by wrapping portions of the first floor with commercial uses and by articulating upper floors with elements that reflect an occupied building. 1. Decorative and interesting architectural elements, such as towers and rotundas, should be utilized at street intersections. These elements could be used for stairwells and/or elevator towers. 2. Parapets should be added to key areas on the structure to change the roof-line and reduce its horizontal appearance. 3. Horizontal openings should be broken up with vertical columns to create a rhythm of openings. 4. Framing should be added to openings to mimic windows. The framing should have vertical members to deemphasize the horizontal lines of the structure. 5. Landscaping should be used to screen and enhance the structure. Landscaping and vines planted on structure façades can help reduce the visual impact of the structure while berms and trees planted at the perimeter of the garage can screen lower levels. 6. Where commercial uses are not provided on the ground floor, the structure should be surrounded by landscaping so that the structure does not directly abut paved areas. A minimum five (5) feet wide landscaping strip should be provided between paved areas and the structure.
(Ord. No. 3053, § 3(Exh. A), 5-14-2025)
Ask a question about El Monte law
Corpus searches the El Monte sections it holds and shows the ones that match, with their citations. Free, no sign-in.
