For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.4.18 — Installation of pipes and conduits

City Code, City of Fairfield, California (Fairfield City Code includes legislation through 07-21-2026 (eCode360 publication FA4438, scraped 2026-11-21)) · Fairfield City Code § 16.4.18

Corpus is an independent public-information project, not the official City of Fairfield website. Stable reference: corpuslaw.us/code/fe35b3a3-e4d9-4bdd-9c57-27966c54a83f

§ 16.4.18: Installation of pipes and conduits.

(a) Method of installation. Installation of pipes and conduits shall be in conformance with current city standard specifications and details. (b) Minimum cover. The minimum cover over any and all pipes or conduits installed with the right of way shall be two feet of earth or imported materials, unless otherwise specified in the permit. Within the public street, the minimum cover of three feet shall be measured from the flow line of gutter, existing or planned. The director of public works is authorized to permit installation of pipes or conduits where three feet of cover cannot be provided because of topography, structures, or other engineering necessity. (c) Backfill. Unless special instructions are otherwise given by the director of public works, the backfilling of an excavation shall be done as specified in the city standard specifications and details. All backfilling shall be done to the satisfaction of the director of public works.

( Ord. No. 74-25 , § 18 )