§ 25.33.10 — Additional Design and Development Standards for Facilities in the Public Right-of-Way
City Code, City of Fairfield, California (Fairfield City Code includes legislation through 07-21-2026 (eCode360 publication FA4438, scraped 2026-11-21)) · Fairfield City Code § 25.33.10
Corpus is an independent public-information project, not the official City of Fairfield website. Stable reference: corpuslaw.us/code/7181fda3-f209-4ce8-bcf9-b8d4a3593c44
§ 25.33.10: Additional Design and Development Standards for Facilities in the Public Right-of-Way.
A. Basic Requirements. Facilities located in the Public Right-of-Way are subject to the design and development standards set forth in this section in addition to all design and development standards that apply to all facilities. 1. Director’s Small Cell Design and Deployment Guidelines. The primary purpose of these guidelines shall be to provide procedural and design guidance and specific design standards and requirements for project applicants proposing Wireless Facilities in the Public Right-of-Way that are subject to the requirements of this section. The Guidelines document is also intended for use and reference by City staff in reviewing and approving designs and verifying compliance with this section. All such guidelines will be publicly available and posted on the public works website. Each application for a Wireless Facility is subject to the most current guidelines, which may be amended from time to time. 2. Right-of-Way Authority. An encroachment permit must be obtained for any work in the Public Right of Way. Only applicants authorized to enter the Public Right-of-Way pursuant to state or federal law or a franchise or other agreement such as a master license agreement with the City shall be eligible for a permit to install or modify a Wireless Telecommunications Facility in the Public Right-of-Way. B. Antennas. 1. Utility Poles. The maximum height of any Antenna mounted to an Existing utility Pole shall not exceed 24 inches above the height of an Existing Utility Pole, unless otherwise required by relevant orders of the California Public Utilities Commission (CPUC), including GO 95. No portion of the Antenna or Equipment mounted on a Pole shall be less than 18 feet above any drivable road surface. All installations on Utility Poles shall fully comply with the CPUC general orders, including, but not limited to, General Order 95, as amended. 2. Street Light Poles. The maximum height of any Antenna mounted to a street light Pole shall not exceed seven feet above the Existing height of a Street Light Pole in a location with its closest adjacent district being a commercial zoning district and shall not exceed three feet above the Existing height of a Street Light Pole in any other zoning district. Any portion of the Antenna or Equipment mounted on such a Pole shall be no less than 18 feet above any drivable road surface. C. Poles. 1. Only Pole-mounted Antennas shall be permitted in the Right-of-Way. All other Telecommunications Towers are prohibited, and no new Poles are permitted that are not replacing an Existing Pole. 2. Designs, plans, and all necessary documents containing the required information related to attachments to City-owned Street Light Poles shall be submitted to the Public Works Department – Traffic Engineering for review and, upon approval by the city engineer, shall be permitted. 3. Poles identified in the application that are determined by the city engineer or their designee as showing signs of damage or corrosion, shall be replaced in kind. Applicants shall pay to the City their cost for replacement. Poles that were determined to have insufficient structural capacity to sustain the additional small cell wireless appurtenances during the required field verification shall require replacement footings designed and constructed, at the applicant’s sole cost, to the satisfaction of the city engineer or their designee. The applicant shall provide certification by a registered structural engineer that the structural integrity of the Street Light Pole is intact. Pole number labels, if incorrect or missing, shall be corrected or installed at the applicant’s sole expense and in accordance to the City specifications. 4. Pole height and width limitations: a. All Poles shall be designed to be the minimum functional height and width required to support the proposed Antenna installation and meet FCC requirements. Poles and Antennas and similar structures shall be no greater in diameter or other crosssectional dimensions than is necessary for the proper functioning of the facility. b. Notwithstanding the above, no facility shall be located on a pole that is less than 26 feet in height and no facility shall exceed 35 feet in height, including, but not limited to the pole and any Antenna that protrudes above the pole. c. Pole mounted Equipment shall not exceed six cubic feet in dimension. 5. If an applicant proposes to replace a pole in order to accommodate the facility, the pole shall match the appearance of the original pole to the extent feasible, unless another design better accomplishes the objectives of this section. Such replacement pole shall not exceed the height of the pole it is replacing by more than seven feet. 6. If an exception is granted for placement of new Poles in the Right-of-Way, new Poles shall be designed to resemble Existing Poles in the Right-of-Way, including size, height, color, materials and style, with the exception of any Existing pole designs that are scheduled to be removed and not replaced, unless another design better accomplishes the objectives of this section. Such new Poles that are not replacement Poles shall be located no closer than 25 feet to an Existing pole. D. Space occupied. Facilities shall be designed to be minimally intrusive to occupy the least amount of space in the Right-of-Way. 1. Location. a) Each component part of a facility shall be located so as not to cause any physical or visual obstruction to pedestrian or vehicular traffic, inconvenience to the public’s use of the Right-of-Way, or safety hazards to pedestrians and motorists. b) A facility shall not be located within any portion of the Public Right-of-Way interfering with access to fire hydrants, fire stations, fire escapes, water valves, underground vaults, valve housing structures, or any other vital public health and safety facility. c) Where permitted by the width of the Right-of-Way, new or replacement Poles shall be setback a minimum of 18 inches from the front of the face of a curb, unless otherwise required to comply with ADA requirements. No new pole shall obstruct the line of sight standard at intersections or driveways. d) Each pole mounted Wireless Facility must be separated by at least 500 feet. e) All cables, including, but not limited to, electrical and utility cables, between the pole and any Accessory Equipment shall be placed underground, if feasible. f) All new wires needed to service the Wireless Telecommunications Facility must be installed within the width of the Existing utility pole so as to not exceed the diameter and height of the Existing utility pole. 2. Americans with Disabilities Act Compliance. All facilities shall be built in compliance with the Americans with Disabilities Act (ADA). 3. Documentation. The applicant shall provide documentation satisfactory to the Director of Public Works establishing compliance with this subsection.
( Ord. No. 2021-09 , § 3 )
Ask a question about Fairfield law
Corpus searches the Fairfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.
