§ 30-444 — Additional development standards in R-2 and R-3 zoning districts
Code of the City of Fontana, California (Supp. No. 65: codified through Ordinance No. 1987, enacted April 28, 2026) · Fontana Zoning and Development Code § 30-444
Corpus is an independent public-information project, not the official City of Fontana website. Stable reference: corpuslaw.us/code/932b979b-f7f4-42be-83cc-cbf735b44a26
Sec. 30-444. - Additional development standards in R-2 and R-3 zoning districts.
Residential development standards are basic standards designed to create quality residential developments. The residential development standards indicated in Table No. 30-434 (residential development standards) and Table No. 30-437 (density bonus residential development standards) serve as the minimum standards controlling development. In addition to the applicable standards indicated in Table No. 30-434 and Table No. 30-437, the following standards shall be required of all multiple-family residential developments in the R-2 and R-3 zoning districts. (1) Building separation. Table No. 30-444 sets forth specific standards for minimum building setbacks as follows: Table No. 30-444 Building Separation Requirements Building (b) Setback and Separation (in feet) to Adjacent Zones | R-2 | R-3 R-E | 75-foot | 75-foot R-1 | 25-foot | 25-foot R-2 | 10-foot | 25-foot R-3 | 10-foot | 10-foot R-PC | 25-foot | 50-foot All other zoning districts | 20-foot | 20-foot Single-Family Detached - Minimum Building to Building | 10-foot | 10-foot Single-Family Detached - Minimum Distance to Public Right | 15-foot | 15-foot Attached/Multi-Family Building to Public Rights-of-Way (streets) | R-2 | R-3 Major or primary | 30-foot | 30-foot Secondary or collector | 25-foot | 25-foot Local | 20-foot | 20-foot Attached/Multi-Family - Minimum Building to Building Distance | R-2 | R-3 Front to front | 25-foot | 25-foot Front to side | 25-foot | 25-foot Front to rear | 25-foot | 25-foot Rear to side | 15-foot | 15-foot Rear to rear | 15-foot | 15-foot Side to side | 15-foot | 15-foot Parking and Drive Aisle Setbacks to Adjacent Zoning Districts | R-2 | R-3 All residential | 10-foot | 10-foot All other | 10-foot | 10-foot Parking Setback to Public Rights-of-Way (streets) (h) | R-2 | R-3 Major or primary | 25-foot | 25-foot Secondary or collector | 20-foot | 20-foot Local | 15-foot | 15-foot Private street or driveway | 5-foot | 5-foot [Notes:} Additional standards pertaining to the R-2 and R-3 zoning districts: (a) For the purpose of this table, accessory structure means a subordinate structure which is incidental and not attached to a building but is on the same lot. If an accessory structure is attached to the building, or if the roof is a continuation of the building roof, the accessory structure shall be considered an addition to the building. (b) Building shall mean dwelling units. For purpose of this table, building setback standards shall be for two-story development, setback standards may be modified by other lettered notes herein. (c) Subtract ten feet for a single-story dwelling unit or a multi-story dwelling unit having a single-story element with a depth of at least ten feet. (d) "Front" is defined as that face of the building or unit with a major glass area and/or major private recreation area and may include access to that private recreation area. This access may or may not relate to the primary entrance to the building that faces the street or drive; therefore, some buildings may have more than one "front" under this definition. (e) The "rear" of a building is defined as the point or area farthest from the front. Where a building is identified to have two fronts the building may be considered not to have a rear facing. For the purpose of this table, zoning districts are not considered adjacent if separated by a dedicated public right-of-way of more than 50 feet in width. (f) Balconies, patios (uncovered and covered), patio fences/walls, porches, and similar liked structures may project into the setback area up to a maximum of six feet, providing, however, that such structures shall never be separated by less than 15 feet (horizontal). (g) Buildings may be staggered to encroach into the required setback up to a maximum of five feet, provided there is an equal or greater setback at the opposite/other face of the building. Such staggered encroachment shall be averaged so that for each building which encroaches into the setback, another building will offset such encroachment by an equal number of feet along the same frontage. (h) Where there is a grade differential between properties of greater than ten feet (as determined by the precise grading plan), the setback requirement may be modified as follows: when the building is at the lower grade, the required setback may be reduced by one linear foot for each three vertical feet of difference. Where the building is at the higher grade, the required setback shall be increased by one linear foot for each three vertical feet of difference. Such modification to the required setback shall be limited to a maximum of ten feet. (i) The pedestrian walkway may project into the setback area provided a minimum ten-foot area is maintained free and clear for landscaping. (2) Separation of accessory buildings, parking areas, and vehicular access ways. a. Distance between an accessory building and side and rear property lines shall be no less than ten feet. Where the adjacent zoning district is nonresidential or for safety, as determined by the Police Department, garages and carports may encroach a maximum of 50 percent into the required width of the side or rear setback. b. Distance between two accessory buildings shall be no less than ten feet. c. Distance between an accessory building and any dwelling unit shall be no less than 15 feet. d. Distance between open, guest parking areas and any dwelling unit shall be no less than ten feet. e. Distance between vehicular access way and any dwelling unit shall be no less than ten feet. f. If a carport is located no less than ten feet from a side or rear property line, the rear wall of the carport may have openings to allow view and accessibility to an adjacent landscaped area, as illustrated in the design guidelines. g. Detached assigned and/or required parking stalls, carports and enclosed garages shall be located no more than 150 feet from the dwelling unit they serve, unless otherwise approved by the Director of Planning. (3) Minimum driveway access width. Minimum access way width of 26 feet is required for all access drives serving multiple-family developments. A minimum access way width of 30 feet is required for all access drives serving multi-family developments of three stories or more. (4) Water heaters. Each dwelling unit shall have a separate hot water heater or may be provided with a centralized circulation water heating system sufficient to serve all dwelling units on the property. (5) Laundry facilities. All multiple-family residential units shall be provided washer and dryer hookups and laundry space with the unit or garage. The laundry area shall not infringe upon garage parking area. In the case of apartments, common laundry facilities may be included in addition to the individual unit hookups. (6) Storage facilities. A separate area having a minimum of 125 cubic feet of private and secure storage space shall be provided for each unit. a. Said storage area may be located within an attached garage, provided it does not interfere with garage use for automobile parking. b. Normal closet and cupboard space within the dwelling unit shall not count toward meeting this requirement. c. Storage in carport areas shall be over hood or overhead. Over hood storage shall provide a minimum of four feet of clearance and overhead storage shall provide eight feet of clearance. d. Enclosed garages are required to provide 125 cubic feet of storage cabinet space, or 125 cubic feet of storage space may be provided elsewhere on the site. (7) Garage doors. All garages shall be provided with sectional garage doors and automatic garage door openers. (8) Dwelling entries. a. All units shall be provided with standard door locks and dead bolts. b. No dwelling entry shall be located with direct, uninterrupted, unimpeded access to a primary or secondary arterial street. (9) Refuse storage areas. Individual trash receptacles for each unit shall only be permitted with an approved site layout of refuse pick-up by the City and the authorized refuse hauler. Projects that do not have an approved plan shall provide standard refuse storage facilities for the containment of standard receptacles based on the following requirements: a. Number of receptacles. Number of Units | Types of Receptacles | Number of Receptacles Required 0—8 | 3-yard bin | 1 16—24 | 3-yard bin | 2 Each 8 additional units | 3-yard bin | 1 b. All refuse storage areas shall be readily accessible to the users they serve as well as for collection operations and shall be enclosed by a solid decorative masonry or concrete block wall at least 60 inches in height that shall be designed in a manner architecturally compatible with the overall design of the project's buildings. 1. The site area shall have a concrete pad at least four inches in thickness. 2. The storage area shall be designed with a lattice or metal solid cover matching the exterior building material and color with a solid gate or with mesh. 3. The refuse storage area shall be located within 150 feet walking distance of the unit it services. (10) Recreational facilities. The developer shall provide recreational facilities in conjunction with common open space as a minimum requirement for all projects in the R-2 and R-3 zones. Recreational facilities shall not be required for projects utilizing a minor planned unit development (minor PUD) for development. a. Development consisting of 30 units or fewer shall provide three of the following recreational facilities: 1. Large open lawn area, minimum dimensions shall be 50 feet by 20 feet. 2. Tot-lot with multiple play equipment. 3. Spa and/or pool. 4. Barbecue facility equipped with grill, picnic benches, etc. b. Development consisting of 31 units to 100 units shall provide an additional recreational facility as in (a) above, or equivalent, as approved by the Planning Commission. c. Development consisting of 101 units to 200 units shall provide five of the following recreational facilities, or equivalent, as approved by the Planning Commission: 1. Large open lawn area, minimum dimensions shall be 100 feet by 50 feet. 2. Multiple tot-lots with multiple play equipment. The tot-lots shall be conveniently located throughout the site and separated with a low decorative wall or tubular steel fence from any drive aisle. 3. Pool and spa. 4. Community multi-purpose room equipped with kitchen, defined areas for games, exercises, etc. 5. Barbecue facilities equipped with multiple built in gas grills with shelving, picnic benches and shade structures. The barbecue facilities shall be conveniently located throughout the site. 6. Court facilities (e.g. tennis, volleyball, basketball, etc.). 7. Jogging/walking trails with exercise stations. d. For each 100 units above the first 200 units, another recreational facility as described in Section 30-451, or equivalent, shall be provided for approval by the Planning Commission. e. Other recreational facilities not listed above may be considered subject to the Planning Commission review and approval. f. Related recreational activities may be grouped together and located at any one area of the common open space. g. Recreational facilities shall be dispersed throughout the site. h. All recreational areas or facilities required by this section shall be maintained by private homeowner's associations, property owners, or private assessment districts. (11) Circulation, pedestrian and vehicular parking. a. Pedestrian circulation. Every multiple-family residential development shall be designed in such a manner that adequate walkways are provided convenient to the needs of the residents and guests and the services of public agencies. Pedestrian access to the unifying elements of any development should be separate from and free of conflict with vehicular access ways. All developments consisting of six units or more shall provide directories placed in a convenient location at the development entry. b. Vehicular circulation. Every multiple-family residential development shall be designed with an internal street and parking system adequate to handle the need for vehicular circulation. Said system shall be in compliance with all applicable standards of this chapter.
(Ord. No. 1865, § 8(Att. 2), 3-23-21; Ord. No. 1936, § 4(Exh. A), 12-12-23)
Ask a question about Fontana law
Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.
