§ 30-454 — Mixed use development standards
Code of the City of Fontana, California (Supp. No. 65: codified through Ordinance No. 1987, enacted April 28, 2026) · Fontana Zoning and Development Code § 30-454
Corpus is an independent public-information project, not the official City of Fontana website. Stable reference: corpuslaw.us/code/ea8f1fec-ade5-4971-b59f-eff7da20377e
Sec. 30-454. - Mixed use development standards.
Table No. 30-454 Mixed Use Development Standards Maximum Density | R-4 | R-5 Maximum permitted number of dwelling units per adjusted gross acre | 24.1-39.0 | 39.1-50.0 Maximum floor area ratio FAR | 5.0 | 5.0 Lot Dimensions for New Lots, Lot Size, and Lot Coverage Minimum width at front P/L | 200-foot | 200-foot Minimum depth | 300-foot | 300-foot Minimum lot size (sq. ft.) (a) | 2 acres | 2 acres Maximum lot coverage (adjusted gross acreage of total site) | 70% | 70% Multiple-Family Minimum Dwelling Size (Standard, Senior and Affordable) Minimum dwelling unit in square feet | 550 sq. ft. | 550 sq. ft. Building Height Maximum height for mixed use building | 55-foot | 55-foot Maximum height of ground floor for mixed use buildings with residential above | 15-foot | 15-foot Maximum number of stories | 4 | 6 Mixed Use (Vertical and Horizontal) Setbacks Onsite Building to Building Building separation and setback | See Table 30-448, On-site Building Separation Requirements Front, Building to Public Right-of-Way (street) Setbacks Major or primary | 0-foot | 0-foot Secondary or collector | 0-foot | 0-foot Local | 0-foot | 0-foot Private street or driveway | 0-foot | 0-foot Corner Lot, Side Building Setbacks to P/L Major or primary | 10-foot | 10-foot Secondary or collector | 10-foot | 10-foot Local | 5-foot | 5-foot Corner Lot, Side Parking Setbacks to P/L Major or primary | 10-foot | 15-foot Secondary or collector | 10-foot | 15-foot Local | 10-foot | 10-foot Side (interior), Building Setback to Adjacent Zoning Districts R-1 | 25-foot | 25-foot R-2 (Single-family use) | 25-foot | 25-foot R-2 (Multi-family use) | 15-foot | 15-foot R-3 | 15-foot | 15-foot R-4 | 0-foot | 0-foot R-5 | 0' | 0' R-PC, Single-family | 75-foot | 75-foot R-PC, Specific plan (b) (single-family/multi-family) | 25-foot/ 15-foot | 25-foot/ 15-foot R-E | 75-foot | 75-foot P-PF | 30-foot | 30-foot C-2 | 0-foot | 0-foot All other zoning districts, (C-1, RMU, and OS) | 20-foot | 20-foot Parking Area and Drive Aisle Setbacks to Adjacent Zoning Districts All residential | 5-foot | 5-foot All other | 5-foot | 5-foot Accessory Structure Setbacks and Separation (in feet) In all cases | See Section 30-449 Mixed Use Open Space Requirements Open space, private ground/upper floor (sq. ft.), minimum | 120/80 | 120/80 Open space, common, as a percentage of adjusted gross acreage of project area, minimum. | 20% | 20% Open space, useable, (combined total of private and common open space), as a percentage of adjusted gross acreage of project area, minimum. | 25% | 25% Notes: (1) For existing legal lots smaller than this minimum, see Section 30-414 (lot size conformance). (2) A limited amount of parking may be allowed provided that the visual presence of parked cars be minimal and entrances not interrupt pedestrian and retail continuity. (3) All primary ground-floor store front entries fronting Foothill Blvd., Orange Way, Cypress Avenue or Valencia Avenue shall be oriented to the street, not the interior of the development or parking lot. Buildings may be setback an additional eight feet to accommodate outdoor seating areas. (4) Where a new building is to be constructed on a corner lot or intersection, a wraparound building design with an angled corner shall be utilized in order to maximize and encourage pedestrian activity. (5) Setback may be increased to incorporate building design elements such as planter's outdoor seating areas, and street furniture to a maximum of ten feet. (6) Parking setback may be decrease to zero for subterranean parking structures. (7) Subtract ten feet for a single-story dwelling unit or a multi-story dwelling unit having a single-story element with a depth of at least ten feet. (8) Setback from underdeveloped property in the R-2 zone shall be determined at the R-1 single-family zones development standard of 25 feet.
Ask a question about Fontana law
Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.
