§ 15.40.060 — Amendment to 2024 ISPSC Section 311 (Suction Entrapment Avoidance)
Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 15.40.060
Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/92361eff-3cba-4840-a1bc-0a79a8d706b9
15.40.060 Amendment to 2024 ISPSC Section 311 (Suction Entrapment Avoidance).
Section 311 of the 2024 ISPSC is amended as follows: 311.1 {ISPSC text not modified} 311.2 Construction Requirements for building a pool or spa. Whenever a building permit is issued for the construction of a new private swimming pool or spa, the pool or spa shall meet all of the following requirements: 1. The suction outlet of the pool or spa for which the permit is issued shall be equipped to provide circulation throughout the pool or spa as prescribed in Paragraph 2. 2. The swimming pool or spa shall have at least two circulation drains per pump that shall be hydraulically balanced and symmetrically plumbed through one or more "T" fittings, and that are separated by a distance of at least three feet in any dimension between the drains. Suction outlets that are less than 12 inches across shall be covered with anti-entrapment grates, as specified in the ASME/ANSI Standard A 112.19.8, that cannot be removed except with the use of tools. Slots of openings in the grates or similar protective devices shall be of a shape, area and arrangement that would prevent physical entrapment and would pose any suction hazard to bathers. 3. Any backup safety system that an owner of a new swimming pool or spa may choose to install in addition to the requirements set forth in subdivisions (1) and (2) shall meet the standards as published in the document, “Guidelines for Entrapment Hazards: Making Pools and Spas Safer,” Publication Number 363, March 2005, United States Consumer Products Safety Commission. 4. Whenever a building permit is for the remodel or modification of any existing swimming pool, toddler pool or spa, the permit shall require that the suction outlet of the existing swimming pool, toddler pool or spa be upgraded so as to be equipped with an anti-entrapment cover meeting current standards of the American Society for Testing and Materials (ASTM) or the American Society of Mechanical Engineers (ASME). Authority: Health and Safety Code Section 18942(b) Reference: Health and Safety Code Section 115928 AB 3305 (Statutes 1996, c.925); AB 2977 (Statutes 2006, c.926); AB 382 (Statutes 2007, c.596) (Ord. 13-2025 § 8, 11-18-25.)
Ask a question about Fremont law
Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.