§ 15.40.080 — Amendment to 2024 ISPSC Section 504 (Pumps and Motors)
Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 15.40.080
Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/23adeab9-b604-4bfd-9e5b-63e6ad858ed1
15.40.080 Amendment to 2024 ISPSC Section 504 (Pumps and Motors).
Section 504 of the 2024 ISPSC is amended as follows: 504.1 Emergency shutoff switch. One emergency shutoff switch shall be provided to disconnect power to circulation and jet system pumps and air blowers. Emergency shutoff switches shall be clearly labeled, and provided with access. Such switches shall be located within sight of the spa and shall be located not less than 5 feet (1,524 mm) but not greater than 10 feet (3,048 mm) horizontally from the inside walls of the spa. 504.1.1 – 504.2 {ISPSC text not modified} (Ord. 13-2025 § 8, 11-18-25.)