For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.95.050 — Repair criteria

Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 15.95.050

Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/e23daad2-0dd6-48a6-8a4d-fd6566a555d6

15.95.050 Repair criteria.

(a) All repairs and alterations shall comply with the then-current code. (b) Buildings and structures of all types which have been damaged as a result of an event, except as otherwise noted, shall be repaired in accordance with the following criteria: (1) When the estimated value of repair does not exceed 10 percent of the replacement value of the structure, the damaged portion(s) may be restored to their predisaster condition. (A) Exception. Regardless of the estimated value of repair, damaged suspended ceiling systems and bracing contained in such ceiling systems must be repaired, replaced and installed in conformity with the requirements of the current code. (2) When the estimated value of repair is greater than 10 percent but less than 50 percent of the replacement value of the structure, the damaged elements, as well as all critical ties and supporting elements associated with the damaged elements, shall be repaired and/or brought into conformance with the structural requirements of the current code. The design load level for the damaged structure shall be established based upon then-current design practice and as deemed reasonable by the building official. (3) When the estimated value of repair is 50 percent or more of the replacement value of the structure, the structural system of the entire building shall be reevaluated by a registered civil engineer. The civil engineer shall identify structural elements, assemblies and subassemblies that are not in conformance with the current code and have caused or contributed to damage during the event. All the damaged elements, as well as all critical ties and supporting elements associated with the damaged elements, shall be repaired and/or brought into conformance with the structural requirements of the current code. All the undamaged but nonconforming elements that have contributed to the susceptibility of the building to damage during the event shall be retrofitted to a standard deemed reasonable by the building official. (4) In Group R, Division 3 occupancies, the repair value of damaged chimneys shall be excluded from the computation of percentage of replacement value. (5) The repair value of damaged electrical, mechanical and plumbing elements shall be excluded from the computation of the percentage of replacement value. This exemption shall not apply to the valuation of essential buildings. (Ord. 2182 § 1, 6-18-96. 1990 Code § 7-9120.)

Ask a question about Fremont law

Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.