§ 15.95.060 — Repair criteria for essential services facilities

Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 15.95.060

Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/4c63fe56-33bd-4577-8045-1276d6112460

15.95.060 Repair criteria for essential services facilities.

(a) Buildings or structures housing essential service facilities (described in Section 15.95.040(e)) which have been damaged as a result of an event shall have an engineering evaluation performed. (b) Minimum criteria for repair shall be as follows: (1) When the estimated value of repair contained in the engineering evaluation is less than 30 percent of the replacement value of the structure, the damaged elements, as well as all critical ties and supporting elements associated with the damaged elements, shall be repaired and/or brought into conformance with the structural requirements of the current code. The design load level for the damaged structure shall be established based upon then-current design practice and as deemed reasonable by the building official. (2) When the estimated value of repair contained in the engineering evaluation in 30 percent or more than the replacement value of the structure, the structural system of the entire building shall be reevaluated by a registered civil engineer. The civil engineer shall identify structural elements, assemblies and subassemblies that are not in conformance with the current codes and have caused or contributed to damage during the event. All the damaged elements, as well as all critical ties and supporting elements associated with the damaged elements, shall be repaired and/or brought into conformance with the structural requirements of the current code. All the undamaged but nonconforming elements that have contributed to the susceptibility of the building to damage during the event shall be retrofitted to a standard deemed reasonable by the building official. (Ord. 2182 § 1, 6-18-96. 1990 Code § 7-9125.)

Ask a question about Fremont law

Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.